Reliance Water Heaters 196296-001, 606 Series instruction manual Insulation Blankets

Page 10

This water heater must not be installed directly on carpeting. Carpeting must be protected by metal or wood panel beneath the appliance extending beyond the full width and depth of the appliance by at least 3” (76.2 mm) in any direction, or if the appliance is installed in an alcove or closet, the entire floor must be covered by the panel. Failure to heed this warning may result in a fire hazard.

FIGURE 10.

Minimum clearances between the water heater and combustible construction are 0 inch at the sides and rear, 4” (102 mm) at the front, and 6” (153 mm) from the vent pipe. Clearance from the top of the jacket is 12” (305 mm) on most models. Note that a lesser dimension may be allowed on some models, refer to the label attached adjacent to the gas control valve on the water heater, see Figure 9.

If this water heater will be used in beauty shops, barber shops, cleaning establishments, or self-service laundries with dry cleaning equipment, it is imperative that the water heater or water heaters be installed so that combustion and ventilation air be taken from outside these areas.

Propellants of aerosol sprays and volatile compounds, (cleaners, chlorine based chemicals, refrigerants, etc.) in addition to being highly flammable in many cases, will also change to corrosive hydrochloric acid when exposed to the combustion products of the water heater. The results can be hazardous, and also cause product failure.

INSULATION BLANKETS

FIGURE 9.

A gas water heater cannot operate properly without the correct amount of air for combustion. Do not install in a confined area such as a closet, unless you provide air as shown in the Locating The New Water Heater section. Never obstruct the flow of ventilation air. If you have any doubts or questions at all, call your gas supplier. Failure to provide the proper amount of combustion air can result in a fire or explosion and cause death, serious bodily injury, or property damage.

10

Image 10
Contents Residential GAS Water Heaters Safe INSTALLATION, USE and Service Important DefinitionsGeneral Safety Table of Contents IntroductionTypical Installation GET to Know Your Water Heater GAS ModelsMixing Valve Usage Removing the OLD Water Heater Deciding on the Type of Installation Materials and Basic Tools NeededLocating the NEW Water Heater Facts to Consider about the LocationInsulation Blankets ALL AIR from Inside Buildings See Figures 10 Page Installing the NEW Water Heater Section a Galvanized PipingSection B Copper Sweat Piping Page TEMPERATURE-PRESSURE Relief Valve Filling the Water Heater VentingGAS Piping GAS Piping with Flexible Connector Sediment TrapsFor Your Safety Read Before Lighting For Your Safety Read Before Lighting Start UP Conditions Temperature RegulationFor Your Information Draft Hood OperationStrange Sounds Smoke / OdorThermal Expansion Smelly WaterVenting System Inspection Periodic MaintenanceHigh Water Temperature Shut OFF System Burner InspectionHousekeeping Burner CleaningTEMPERATURE-PRESSURE Relief Valve Operation Anode ROD InspectionDrain Valve Washer Replacement ServiceLeakage Checkpoints Troubleshooting Guidelines Problem Cause SolutionDrain PAN Repair Parts ListT&P Relief Valve Model Series Service and Labor ResponsibilityConditions and Exceptions Limitation on Implied Warranties Claim ProcedureInstallation Information DisclaimersLindahl Parkway Ashland City, TN