Reliance Water Heaters 606 Series, 196296-001 instruction manual Leakage Checkpoints

Page 27

LEAKAGE CHECKPOINTS

A.Water at the draft hood is water vapor which has condensed out of the combustion products. This is caused by a problem in the vent. Contact the gas utility.

B.*Condensation may be seen on pipes in humid weather or pipe connections may be leaking.

C.*The anode rod fitting may be leaking.

D.Small amounts of water from the temperature-pressure relief valve may be due to thermal expansion or high water pressure in your area.

E.*The temperature-pressure relief valve may be leaking at the tank fitting.

F.Water from a drain valve may be due to the valve being slightly opened.

G.*The drain valve may be leaking at the tank fitting.

H.Combustion products contain water vapor which can condense on the cooler surfaces of the tank. Droplets form and drip onto the burner or run on the floor. This is common at the time of start-up after installation and when incoming water is cold.

I.Water in the water heater bottom or on the floor may be from condensation, loose connections, or the relief valve. DO NOT replace the water heater until a full inspection of all possible water sources is made and necessary corrective steps taken.

Leakage from other appliances, water lines, or ground seepage should also be checked.

*To check where threaded portion enters tank, insert cotton swab between jacket opening and fitting. If cotton is wet, follow “Draining” instructions in the “Periodic Maintenance” section and then remove fitting. Put pipe dope or teflon tape on the threads and replace. Then follow “Filling the Water Heater” instructions in the “Installing the New Water Heater” section.

27

Image 27
Contents Residential GAS Water Heaters Important Definitions Safe INSTALLATION, USE and ServiceGeneral Safety Introduction Table of ContentsGET to Know Your Water Heater GAS Models Typical InstallationMixing Valve Usage Removing the OLD Water Heater Materials and Basic Tools Needed Deciding on the Type of InstallationFacts to Consider about the Location Locating the NEW Water HeaterInsulation Blankets ALL AIR from Inside Buildings See Figures 10 Page Section a Galvanized Piping Installing the NEW Water HeaterSection B Copper Sweat Piping Page TEMPERATURE-PRESSURE Relief Valve Venting Filling the Water HeaterGAS Piping Sediment Traps GAS Piping with Flexible ConnectorFor Your Safety Read Before Lighting For Your Safety Read Before Lighting Draft Hood Operation Temperature RegulationFor Your Information Start UP ConditionsSmelly Water Smoke / OdorThermal Expansion Strange SoundsBurner Inspection Periodic MaintenanceHigh Water Temperature Shut OFF System Venting System InspectionAnode ROD Inspection Burner CleaningTEMPERATURE-PRESSURE Relief Valve Operation HousekeepingService Drain Valve Washer ReplacementLeakage Checkpoints Problem Cause Solution Troubleshooting GuidelinesRepair Parts List Drain PANT&P Relief Valve Service and Labor Responsibility Model SeriesConditions and Exceptions Disclaimers Claim ProcedureInstallation Information Limitation on Implied WarrantiesLindahl Parkway Ashland City, TN