WhisperKool SS4000, SS7000 owner manual PDT Operating Instructions, Pdt

Page 6

PDT OPERATING INSTRUCTIONS

The unit is set at 55°F at the factory. To raise or lower the temperature set point, press the set button while at the same time pressing either the arrow up or arrow down button.

1WINE Temperature Indicator

Wine Temperature Reading

3

2 LED Screen

 

 

WINE 55F ON

SET

PDT

Precision digital Technology Thermostat

Temperature

SET

4

Temperature SET Indicator

7 UP Arrow Button

8 DOWN Arrow Button

5

Unit ON Indicator

6 SET Temperature Button

 

1.Wine Temperature Indicator: A red LED bar will light up when the thermostat is reading the liquid temperature in the bottle via the probe. This will remain lit and the temperature you see displayed is what the probe is reading.

2.LED Screen: Displays your thermostat readings.

3.Wine Temperature Reading: The temperature the water bottle is registering to the thermostat.

4.Temperature SET Indicator: A red LED bar will light up when you are setting the temperature.

5.Unit ON Indicator: A red LED bar will light up every time the unit turns on to run a cooling cycle.

6.SET Button: Used to set the temperature you want the unit to maintain.

7.UP Arrow Button: Used with the SET button to set temperature higher. In addition, by pressing and holding the button it will allow you to see the 5-minute count down.

8.DOWN Arrow Button: Used with the SET button to set temperature lower.

*Up and Down Arrow Buttons used simultaneously will change the temperature read out from Fahrenheit to Celsius*

-6-

Image 6
Contents WhisperKOOL Page Table of Contents Temperature Differential Features & BenefitsCondensing Unit Installation, Indoors or Outdoors Humidity ControlAdditional Features ThermostatEvaporator PDT Operating Instructions PDTPackage Contents Preparing the Wine Cellar Technical Specifications Wine Cellar / Space PreparationInstalling Condensing Unit Split System Installation GuidelinesGeneral Installation Guidelines and Instructions Mounting Evaporator UnitCondensing Unit Skid Preparation Condensing UnitHead Pressure Control, Low Ambient Control Switch Remove interior assembly Mounting the Evaporator UnitDisassemble evaporator unit Mounting housing to wall Identify and remove appropriate knockoutsInstalling refrigeration lines into evaporator housing Re-install interior assembly Attaching refrigeration lines Install drain line fitting and drain line FanF1 J1 T3 J1 S1 S2 Thermostat Solenoid ValveInstall thermostat Install front cover Energize unitWiring System Split System Wiring SchematicRefrigeration Lines Split Unit Wiring Diagram Maintenance How To Contact Vinothèque Customer Service Technical AssistanceWine cellar temperature above thermostat set point TroubleshootingFault Cause Solution Water leaking from unitCompressor runs intermittently And/or cause for hot air recirculationCheck refrigerant sight glass in 1/4 tubing Evaporator blower runs, but compressor does notCompressor runs, but evaporator does not Evaporator coil freezesHumidity in cellar too high Installation Terms and Conditions Acceptance of Terms & Conditions Product InstallationMaintenance Customer Service Arbitration Questions or Additional Information Page Page