How to Install Your CO Alarm (cont.)
11. Firmly PRESS AND RELEASE THE |
|
| |
PRESS |
| ||
TEST/RESET button. See Figure 7. |
| ||
IN, HOLD, |
| ||
The alarm should sound a short |
| ||
AND |
| ||
tone. The amber SERVICE light will | RELEASE |
| |
turn on, and the CO alarm will go | TO |
| |
through its test cycle. The red LED | RESET |
| |
will flash, and the alarm will beep | AND/OR |
| |
four times followed by 5 seconds of | TEST. |
| |
silence and then repeat the cycle. |
|
| |
|
| ||
After the test cycle, the amber |
|
| |
| FIGURE 7 | ||
SERVICE light will turn off, and the green | |||
| |||
POWER light will remain lighted which means |
| ||
the CO alarm is operating properly. |
|
|
12.If the alarm is interconnected to other CO alarms, press and hold the TEST/RESET button until the red light turns on. Other interconnected alarms also will beep four times followed by 5 seconds of silence. The red ALARM light on other alarms will not light during this test. If the alarm is interconnected with smoke or heat alarms, the smoke and heat alarms will remain silent.
13.Two
How to Operate Your CO Alarm
This carbon monoxide alarm has been evaluated by UL and meets the applicable UL standards and requirements.
This CO alarm has a three light and sound alarm system:
CARBON MONOXIDE ALARM
ON |
|
|
|
| SERVICE |
|
|
| ALARM: |
|
|
|
|
|
|
|
|
| MOVE TO FRESH AIR |
|
|
|
|
|
|
|
|
|
|
On
(Power on/ operating)
Service
(Problem with Alarm)
Green indicator constantly ON indicates unit is receiving AC power.
Amber indicator flashing and alarm horn beeping every thirty seconds indicates unit fault. Press and release the TEST/RESET button. If the alarm returns to displaying the fault signal, the CO alarm is not operating properly.
REPLACE THE CO ALARM IMMEDIATELY. SEE THE WAR- RANTY INFORMATION AT THE END OF THIS MANUAL.
Alarm | Red indicator flashes and alarm horn sounds four fast |
(Dangerous CO levels) | beeps and then is quiet for 5 seconds. |
When the CO concentration builds to a level that is equal to 70 ppm or greater for the duration identified within the standard, the following will occur:
•The ALARM light and sound signals will activate. See the WHAT TO DO IF YOUR ALARM SOUNDS section of this manual for important action steps to be taken.
•If you wish to press the TEST/RESET button during this time, the alarm will become quiet for up to six minutes. The ALARM signals will be reenergized within 6 minutes from the time the reset button is pressed if the concentration of carbon monoxide surrounding the alarm remains at 70 ppm or greater.
•The alarm will remain silent if the CO concentration has decreased below the alarm level of the standard. See WHAT TO DO IF YOUR ALARM SOUNDS section of this manual for important action steps to be taken.
•The alarm will continue for as long as the condition exists.
The alarm will not permanently end its alarm mode until the concentration of CO has been reduced to a safe level.
Español
Características de la alarma de CO (continuación)
!ADVERTENCIA
Esta alarma está diseñada para detectar el gas monóxido de carbono de cualquier fuente de combustión, NO está diseñada para detectar humo, fuego ni ningún otro tipo de gas. Si suena la sirena de la alarma de CO, no suponga que se trata de una falsa alarma, sino, préstele atención inmediata.
!ADVERTENCIA
Este producto es para usarse en lugares comunes dentro de viviendas familiares. No está diseñado para medir el cumplimiento con las normas comerciales o industriales de la Administración de Seguridad y Salud Ocupacional de los Estados Unidos (OSHA).
Dónde instalar la alarma de CO
!ADVERTENCIA
El gas monóxido de carbono puede estar en cualquier parte y en todas partes, pesa lo mismo o es ligeramente más liviano que el aire y se dis- persa uniformemente con el aire de la habitación. Por consiguiente, instale esta alarma de CO donde el aire circule mejor. NO instale la alarma de CO a un pie 30 cm (1 pie) o menos de la intersección de la pared con el cielo raso, en la intersección de dos paredes, ni en otros espacios de “aire muerto”.
Ya que la mayoría de las muertes por CO ocurren mientras las familias están durmiendo, recomendamos que instale, por lo menos, una alarma en los pasadizos de las diferentes áreas de dormir y otra alarma en cada uno de los dormitorios o áreas de dormir.
También recomendamos que instale una alarma en cada una de las áreas o habitaciones de los diferentes niveles donde los miembros de la familia están con frecuencia, así como en el sótano. Las figuras 1, 2 y 3 mues- tran las ubicaciones típicas de las alarmas dentro de la casa.
Esta alarma puede compartir el cable de interconexión de las alarmas de humo y calor, PERO esta alarma permanecerá en silencio si el humo es detectado por las alarmas interconectadas de humo y calor. Por lo tanto,
5