Bacharach RDM800 warranty HGM300 Voltage Check, Connector J9

Page 12

SECTION 7

Z3 – 15 VDC

HGM300 Voltage Check

Red Blinking LED

Indicates Communication

Functioning

Bench resistance

Is about 1.0 ohms

Z2 + 15 VDC

NOTE- Z1, Z2 & Z3

+ POS

NEG -

2 RED LEDS POWER SUPPLY INDICATORS TOP +15 VDC SECOND -15VDC

Z1 Voltage +5VDC

Connector J9

Pin (-) 1 to Pin 10 (+)

+5 volts DC (Communication voltage)

Pin (-) 1 to Pin 8 (+) -15 volts DC

Pin (-) 1 to Pin 9 (+) +15 volts DC (Bench voltages)

1 RED LED POWER SUPPLY INDICATOR +5vdc

1 ORANGE LED POWER SUPPLY INDICATOR LOCATED AFTER 1 AMP FUSES

JUMPER FROM POWER SUPPLY

WIRE 1 AND 2 ARE 5 V DC TO WIRE 4 OR 5

Note –If no +15 volts the top red led on the power supply will be out. Disconnect the top jumper from the power supply to the main PC board. If the top led is now on the problem is in the HGM300 main PC board.

Rev 3/2/09

12

Image 12
Contents HGM300/RDM800 Preventative Maintenance and Technical Support HGM300 / RDM800 Technical Support Notes HGM300 CPU Reset RDM800 CPU ResetTo Bypass the Warm UP Mode Monitor will not Come OUT of Warm UPCommon RDM800 Indications Section Alarm LineSection No Flow Check Procedure Rev 3/2/09 No Flow Problems HOW to Force Taking NEW Pressure Readings Clipping Fault Adjustment Page Connector J9 HGM300 Voltage CheckAlarm Detail Screen HOW to Silence Alarms on the HGM300Sample Flow Ndir Source Rev 3/2/09 Materials Used Rev 3/2/09 Procedure Materials UsedRev 3/2/09 Rev 3/2/09 Contact Peter Pape