Heatmaster Gas Burner Sand and Glowing Ember Placement Natural GAS, LOG Placement, Damper Stop

Page 5

SAND AND GLOWING EMBER PLACEMENT (NATURAL GAS)

1.Open the bag of sand and pour over the pipe filling the pan of the back pan burner.

2.Pour the sand over the pipe, filling the bottom pan, following the contour of the pan.

3.Open the bag of glowing ember material and disperse it on top of the sand on the back and bottom pan burner.

VERMICULITE AND GLOWING EMBER PLACEMENT (LP GAS)

1.Open the bag of vermiculite and pour over the pipe filling the pan of the back pan burner.

2.Pour the vermiculite over the pipe, filling the bottom pan, following the contour of the pan.

3.Open the bag of glowing ember material and disperse it on top of the vermiculite on the back and bottom pan burner.

LOG PLACEMENT

1.Remove the fiber log and place it in the middle of the burner unit, with the charred face of the log facing the room. Line up the two holes in the bottom of this log with the two 3/8” pegs and gently slide the log over the pegs until it rests on the grate. (Do not force.)

2.Remove the longest log and place on the grate in front of the fiber log. The bark side should be facing the room.

3.Remove the next longest log and place it on the back of the grate behind the top pan burner. The bark side should be facing the room.

4.Remove the rest of the logs and place on top of the back log and fiber log as shown in the diagram on page 6.

Please refer to the log photos on page 6. Your logs should be placed in the same position as those shown for your corresponding log set.

DAMPER STOP

When log set is operating, damper must be fully open or as per the chart on page 3 of this manual.

Included in the burner assembly box is a damper stop clamp which attaches to the damper as shown in Figure 5. Install it on the damper blade and tighten with a wrench.

Fig. 5

5

Image 5 Contents
For Your Safety What to do if YOU Smell GAS For Your SafetyGeneral Information Venting System MaintenanceCleaning Your GAS LOG SET Chimney Height Feet Log Set General Installation HOW to Install Your GAS LOG SETBurner Assembly and Installation Connecting GAS SupplyVermiculite and Glowing Ember Placement LP GAS Sand and Glowing Ember Placement Natural GASLOG Placement Damper StopCHML-18 CHML-24 LOG Placement PhotosTo Turn OFF GAS to Appliance For Your Safety Read Before LightingLighting Instructions Safety Pilot Valve Lighting Instructions Manual Valve Lighting Instructions Rotary Control Valve Operation of the Remote Control and Wall Switch Remote ControlWall Switch Description Parts List