Cal Flame BBQ11955P manual Troubleshooting, Problem Smell of gas is present

Page 25

Appendix

Troubleshooting

Problem: Smell of gas is present

Solution: Check for loose connections in the gas line. Perform a leak test following the procedure on page 9.

Problem: Burner does not ignite

Solution: Use the following procedure with the figure below.

Check the position of the sparker tip. It should be point- ing forward towards the front of the burner.

Make sure there is a blue spark at the electrode tip to the burner.

Make sure the igniter wire is connected firmly to the valve ignition device and the electrode.

Make sure the valve orifice is free of any debris, dust or grease.

Make sure the valve orifice is aligned inside the front hole of the burner.

If there is no spark at all, replace the electrode or igniter wire.

Note: Turn off the gas at the source while troubleshoot- ing.

23 Appendix

Power Burner

LTR50001100, Rev. A

www.calflamebbq.com

Image 25 Contents
Page Using Your Power Burner Installation / AssemblyCleaning and Maintenance AppendixCal Flame Power Burner is designed for outdoor use only Placement and LocationSet-Up What To Do If You Smell Gas OperationPrecautions Regarding Children Maintenance and RepairStorage Converting the Power Burner Installation / AssemblyCabinet Cut-out Dimensions LP Gas Cylinder SpecificationTank Requirements Transporting and Storing LP Gas LP Gas Hook UpRequirements Natural GasConnection Leak Testing Procedure Placing the Power Burner in a Built-in Enclosure Power Burner Controls Using Your Power BurnerBasic Operation Electronic Ignition Lighting the Power BurnerManual Lighting Power Burner Lid Must always be in place during operation Using the Wok RingRemoval Removing and Replacing BurnersReplacement Stainless Steel Care and Cleaning CLR Cleaning Products and MaterialsRinse CleanPolish FireBurners Rust RemovalSteam Cleaning Your Power Burner Covering Your Power BurnerDrip Pan Problem Smell of gas is present TroubleshootingProblem Burner does not ignite Problem Burner tube is misaligned over the orifice Problem Plugged orificeProblem Obstruction in the gas line Problem Yellow FlameProblem Flashback Problem Misalignment of Igniter on BurnerYou must perform both steps Converting from LP to NGNot provided Switching the regulatorAppendix Changing the burner orificesOrifice sizes Inner burner Outer burner Mark the rating plateExtent of Warranty Limited WarrantyWarranty Performance Warranty LimitationsDisclaimers Legal Remedies Customer ServicePower Burner Don’t forget to register your new product at Locating the Product Serial Number