Step 1: Switching the regulator
27
The regulator in the image below has been removed to illustrate this pro- cedure.
1.Remove the LP gas line.
2.Remove the cap fitting from the end of the NG gas regulator.
3.Place the cap fitting over the LP gas inlet.
You will need:
•13 mm open end wrench
•Male flared fitting
(not provided)
•Pipe compound suitable for natural gas
Appendix
4.Insert a male flared fitting (not provided) in the NG gas regula- tor.
NOTE: A flared fitting is NOT included.
If you are attaching a flex hose to the regu- lator, you will need a fitting. The fitting re- quires a male flare on the input end with a 1/2” MPT on the output end. The flared male in- put end needs to be the size of your flex tubing. You can also connect the regulator directly to your NG gas service, which will not require a flared fitting.
Power Burner