Carrier 58MVP instruction manual Variable Speed Condensing Furnace Algorithm

Page 47

VARIABLE SPEED CONDENSING FURNACE ALGORITHM

Using recorded Low Heat (LH) and High Heat (HH) values, calculate the Heat Load (HL) using:

HL=(228 X LH) + (350 X HH)

Calculate Low Heat (LH) on

Unit will initiate the next cycle in Low Heat for a maximum of 16 min. before initiating High Heat if

Is HL < 3648?

Yes

time will be 16 minutes.

Calculate Low Heat (LH) on

the call for heat still exists.

Unit will initiate the next cycle

47

Is HL > 5600?

Yes

time will be 0 minutes.

in High Heat until the thermostat is satisfied.

Is 5600 > HL > 3648?

FEBRUARY 1995

 

 

 

Unit will iniate the next cycle in

 

Yes

 

 

Low Heat to the nearest minute

 

 

 

for a period of time as calculated

 

 

 

 

 

 

by the following:

 

 

 

 

LH run time = (5600 - HL)/122

 

The next cycle will be initiated with the calculated Low fire run time before initiating high heat if a call for heat is still present.

Is there a call

for heat?

The Low Heat and High Heat run times for this cycle will be as calculated.

Thermostat is satisfied.

A95094

Image 47
Contents Troubleshooting Guide Start Here Section ExampleÐCooling Mode ÐVariable Speed Furnace Control ÐWith DE Connection Lowed by the lowest number fault code. Example 13, 13 Service Status Code Example → ÐService Label/Fault Code InstructionsStep Action YES GO to ÐAir Conditioning A/C Airflow Setup Switch Position LEDs 1, 2, 3, or 4 on Solid Solid means on continuously Step Action YES GO to Fault Code Motor MTR2 →44 Page Lowed by the lowest number fault code. Example 14, 14 Fault Code ÐTwo-Speed AC/HP Airflow Requirements CFM ÐContinuous Fan CF Airflow Setup Switch PositionPage · LOW Heat Page →18 →40 Utes 14ÐIGNITION Lockout Ber indicated in Index for Fault Code →26 Turn power off Is inducer blower wheel okay? 55 ¬ Rpmrpm highlow ¬ →20 Index for Fault Code Cleanup and START-UP Instructions Control Center Board Layout and SchematicAppendix a Schematic Diagram Wiring SchematicIsolation Circuits Pressure Check DiagramAppendix B Appendix CAppendix D Quick Motor Test Procedure→33 →59 Example AIR Delivery Curve Ð Appendix EAir Delivery CurveÐ120-20 Air Delivery CurvesAir Delivery Curve Ð Air Delivery CurveÐ100-20Closet Ð Downflow Application Static Pressure Reading Location DiagramsBasement Ð Upflow Application Upflow Total Static Pressure Reading LocationsAttic Ð Horizontal Application Duct Static Check Sheet Quick Reference Information Appendix FThermostat Staging Algorithm Appendix GVariable Speed Condensing Furnace Algorithm Service Training
Related manuals
Manual 12 pages 2.11 Kb

58MVP specifications

The Carrier 58MVP is a high-efficiency gas furnace designed for optimal performance and energy savings. This model represents Carrier's commitment to innovative engineering and advanced technology, making it a preferred choice for homeowners seeking reliable heating solutions.

One of the standout features of the 58MVP is its impressive Annual Fuel Utilization Efficiency (AFUE) rating, which can reach up to 96 percent. This high AFUE rating indicates that the furnace uses less energy to produce heat, leading to lower utility bills and a reduced carbon footprint. The furnace is equipped with a two-stage gas valve that allows it to operate on a low setting during mild weather, providing increased efficiency and comfort.

The 58MVP also features Carrier's Infinity Control system, an advanced programmable thermostat that enables homeowners to customize their heating preferences. This system allows for precise temperature control and scheduling, ensuring that the home remains at a comfortable temperature while minimizing energy consumption.

In addition to its efficiency, the 58MVP is designed with noise reduction technology, including a quiet operating blower and insulated cabinet. This reduces operational sound, allowing for a more peaceful home environment. The model's multi-speed blower motor enhances comfort by providing consistent airflow and further optimizing efficiency.

Durability is a key characteristic of the Carrier 58MVP. It has a stainless-steel heat exchanger that promotes longevity and performance. The furnace is also equipped with a galvanized steel cabinet featuring a powder-coated finish, which protects against rust and corrosion.

The 58MVP is compatible with Carrier's advanced air purification systems, optimizing indoor air quality while heating. With features designed for efficiency, comfort, and durability, the Carrier 58MVP is an exceptional choice for homeowners looking to enhance their heating systems. The combination of advanced technologies, such as the two-stage operation and Infinity Control, positions this furnace as a leader in the market, meeting the needs of today's energy-conscious consumers. Ideal for both new constructions and retrofits, the Carrier 58MVP continues to set the standard for residential heating solutions.