Munchkin Gas-Fired Hot Water Circulating Heater installation manual Drawing 3C

Page 32

GAS-FIRED HEATER Installation Manual

Munchkin Contender Heater with optional VISION 1 system (zoning with circulators)

Space heating mode (w/ submixing)

Drawing 3C

3-way

(manually-set)

mixing valve

vent

make-up water

air handler

optional high limit safety

purge

purge

 

see note 6

low temperature manifold station

balancing valve

anti-scald mixing valve

DHW

P1

temperature

sensor

 

(Vision 1 system)

 

OFF

 

P2

Munchkin

Contender

Heater

T/P

outdoor

temperature sensor

(Vision 1 system) purge

thermal trap

Super Stor Ultra(w/ drain plug) Indirect DHW Tank

NOTES:

1.This drawing is meant to show system piping concept only.

Installer is responsible for all equipment & detailing required by local codes.

2.All closely spaced tees shall be within 4 pipe diameters center to center spacing.

3.A minimum of 6 pipe diameters of straight pipe shall be installed upstream & downstream of all closely spaced tees.

4.The minimum pipe size for connecting a Super Stor Ultra Indirect Water Heater is 1-inch.

5.The minimum pipe size for connecting the Munchkin Contender is 1.25-inch

6.Circulators are shown with isolation flanges and integral check valves. The alternative is standard flanges with full port ball valves and a separate flow check valve. Purge valves can be used with the circulator flanges as an alternative.

7.Optional Vision 1 system includes temperature sensors for DHW and outdoor air and must be purchased separately.

8.The anti-scald mixing valve is recommended if the DHW temperature is set above the factory setting of 119˚F.

9.Install a minimum of 12 diameters of straight pipe upstream of all circulators.

10.Winterization: When winterizing the Munchkin Contender, put a drain valve on both the supply and return between the union and the shut-off connection.

31

Image 32
Contents Installation Manual What to do if YOU Smell GAS Contents Contents CONT’D Part 1 Product and Safety Information DefinitionsMunchkin Contender Operation Heater WaterWinterizing the Munchkin Contender Freeze Protection FluidsModulating Combustion System Gas ValveSupply water temperature sensor Return water temperature sensorTemperature and pressure gauge Swirl Plate SystemInstallations Must Comply with Part 2 HOW the Munchkin Contender Operates CONT’DClearances for Service Access Before Locating the Munchkin ContenderPrevent Combustion AIR Contamination Residential Garage InstallationExhaust Vent and Intake AIR Vent Part 4 Prepare Munchkin Contender Heater Installation Steps Munchkin Contender Wall Mounting InstructionsPart 5 Munchkin Contender Piping Part 5 Munchkin Contender Piping CirculatorsCirculator Sizing System Temperature Rise Chart Fill and Purge Heating SystemMunchkin Contender Piping Zoning with Zone ValvesZoning with Circulators Multiple HeatersPiping symbol legend Contender Piping DetailsStandard Munchkin Contender! Heater zoning with valves Drawing 1AStandard Munchkin Contender Heater zoning with valves Drawing 1BSpace heating zone circuit See note Make-up water Installation Manual GAS-FIRED Heater Installation Manual Space heating zone circuit Zoning with Circulators Using Vision Vision I System PipingDrawing 2A Heater Piping Details with the Vision I SystemDrawing 2B Drawing 2C OFFDrawing 3A Drawing 3B Outdoor Temperature sensor Vision 1 system purge Drawing 3CDrawing 3D Drawing 3E Drawing 3F Drawing 3G General Installing Exhaust Vent and Intake AIR VentExhaust Vent and Intake AIR Vent Pipe Location Part 7 VENTING, Combustion AIR & Condensate Removal Exhaust Vent and Intake AIR Vent SizingInstallation Manual Reference National Fuel Gas Code Ansi Z223.1/NFPA 54 Installation Exhaust Vent and Intake AIR PipeHeater Removal from a Common Vent System Vent Termination Kits Description Stock CodeCanada Condensate Removal SystemMaterial Diagrams for Sidewall Venting Sidewall Venting with KIT12 2 roof vent with tee intake & coupling exhaust Part 8 GAS Piping GAS ConnectionGAS Piping GAS TableDungs GAS Valve TAP InletInstallation Must Comply with Field WiringLine Voltage Wiring ThermostatPart 9 Field Wiring Part 9 Field Wiring Part 10 Field Wiring Vision 1 Option Indirect Circulator P2 ProgramFreeze Protection When Used Part 11. START-UP PreparationCHECK/CONTROL Water Chemistry Fill and Test Water SystemCheck Thermostat Circuits Check for GAS LeaksPurge AIR from Water System Part 12. START-UP Procedure Condensate RemovalPart 12. START-UP Procedure Adjusting the SetpointOperating Instructions Status MenuProgramming the Vision I Option Test ModeVision 1 Program Access Vision 1 Program Navigation Central Heating Curve Function Default Function Function Value DescriptionFunction Control Program Reference Chart Function Default Setting Programmed SettingHeater Fault Munchkin Error CodeHeater Error Part 14 Troubleshooting 925 Control Board Fault Codes Description RemedyMaintenance Procedures Outdoor Sensor 7250P-319For GAS Leaks Sure Exhaust Vent is no Longer BlockedPart 15 Maintenance Replacement PartsReplacement Parts Replacement Parts Heater Start UP Report Light Off ActivitiesHeater Inspection and Maintenance Schedule Heater Inspection and Maintenance Schedule Maintenance Notes Maintenance Notes 2007, 2006 Heat Transfer Products, Inc LP-171 REV /20/07

Gas-Fired Hot Water Circulating Heater specifications

The Munchkin Gas-Fired Hot Water Circulating Heater is a cutting-edge heating solution designed to provide efficient and reliable hot water for residential and commercial applications. Renowned for its compact design and innovative technology, the Munchkin heater combines performance with energy efficiency, making it an ideal choice for those seeking comfort and cost savings.

One of the main features of the Munchkin heater is its modulating burner. This technology intelligently adjusts the heating output based on the demand for hot water, ensuring that energy is not wasted. This leads to lower energy bills and a reduction in environmental impact, as the system only uses the necessary resources to maintain desired water temperatures.

Another notable characteristic is its high-efficiency rating. The Munchkin heater operates with an impressive annual fuel utilization efficiency (AFUE) of up to 95%. This means that the majority of the fuel consumed is converted into usable heat. By maximizing energy utilization, homeowners can enjoy a significant reduction in utility costs while minimizing emissions.

The compact size of the Munchkin Gas-Fired Hot Water Circulating Heater is another significant advantage. It is designed to fit into tight spaces, making it suitable for homes where space is at a premium. This compact design does not compromise performance; instead, it enhances installation flexibility, allowing for placement in basements, closets, or utility rooms.

Munchkin heaters are equipped with advanced control systems that offer enhanced convenience. The digital display and programmable settings allow users to set their preferred temperatures and schedules. This feature not only enhances user comfort but also optimizes energy usage, as water is heated only when necessary.

Safety is also a top priority with Munchkin products. The heater includes built-in safety features such as flame monitoring systems, automatic shut-off capabilities, and pressure relief valves, providing peace of mind for users.

In summary, the Munchkin Gas-Fired Hot Water Circulating Heater is a high-efficiency, compact, and innovative solution for hot water needs. With its modulating burner, high-efficiency rating, advanced control systems, and safety features, it stands out as a reliable choice for those looking to invest in heating technology that prioritizes energy conservation and performance. This heater is truly a forward-thinking solution for modern hot water requirements.