Lochinvar 50-210 service manual What is in this manual?, Service, Maintenance, Troubleshooting

Page 5

What is in this manual?

Service

Near boiler piping

• Typical system components

The Knight wall mount boiler display

• Display panel readout, buttons and their functions

Control module inputs

• Control module inputs and options

Control module outputs

• Control module outputs and options

General

How the boiler operates

How the control module operates

Access modes -- user and installer

Sequence of operation -- Domestic Hot Water (DHW)/space heating

Control panel menu access

Accessing programming mode and locating menus (See separate guide covering the PC interface.)

Control panel parameter access

• Accessing and changing parameters from the display panel

Quick start information -- parameter table

An index of available adjustments and readouts, where to access them and where to find detailed information.

Knight wall mount boiler operation

A: General

B: Temperature Setting

C: Data Logging

D: Functions

E: DHW Settings

F: Outdoor Air Reset Curve

G: Anti-cycling

H: Control Modes

I: Circulation Pumps

J: Service Notification

Service Manual

Maintenance

Service and maintenance schedules

Address reported problems

Inspect boiler area and boiler interior

Clean condensate trap

Check all piping for leaks

Check air openings

Flue vent system and air piping

Check water system

Check expansion tank

Check boiler relief valve

Inspect ignition electrode

Check ignition ground wiring

Check all boiler wiring

Check control settings

Perform start-up and checks

Check burner flame

Check flame signal

Check flue gas temperature

General maintenance

Review with owner

Cleaning boiler heat exchanger

Oiled bearing circulators

Troubleshooting

Troubleshooting table - No display

Checking temperature sensors

Sensor tables

Troubleshooting table - Fault messages displayed on boiler interface

Combustion analysis procedure

Gas valve adjustment procedure

5

Image 5
Contents Models 50 Contents Niosh stated First Aid Please read before proceedingHandling ceramic fiber materials When servicing boiler Service What is in this manual?Maintenance TroubleshootingNear boiler piping ServiceKnight wall mount display Control inputs Smart Control ModuleControl outputs How the boiler operates General OperationHow the control module operates Sequence of operationOUT 123.8F129 Sequence of operationBLR SH 41% Rate Display panel menu access Display panel parameter access Parameter table Temperature DataControl Circulation Service Viewable and changeable control parameters Temperature settingsOutdoor air reset DHW settingsData logging FunctionsMaximum SH set point Shift reset curveMinimum SH set point Outdoor air shutdownAnti-cycling SH controlling sensor Control modesSH source Boiler cascade addressCirculation pumps Service NotificationCascade offset Owner maintenance Maintenance Maintenance and annual startupService technician Maintenance Check water system Flue vent system and air pipingCheck expansion tank Check boiler relief valveCheck all boiler wiring Check ignition ground wiringCheck control settings Inspect ignition and flame sense electrodesCleaning boiler heat exchanger Check flame signalReview with owner Oiled bearing circulatorsBefore troubleshooting TroubleshootingCheck control module fuses Check the followingNo Burner No DisplayOperation Unit Does NotTemperature Resistance Checking temperature sensorsNo Pump NoisyBoiler Pump System Pump DHW PumpFlow Switch/LWCOFlame SequenceNo Flame Ign Anti-cyclingRunning No FlameHigh Limit Auto ResetFan Low Fan Speed LowFan Speed High Fan HighSensor Open Sensor ShortedTemp O/Shoot Open Rem Ctrl FltParameters Progr Watch Dog Error Service BlkNo Error Stored Low 24 vacGas Valve Adjustment Combustion Analysis ProcedureOr Obstruction Gas Supply Pressure2Gas Valve Adjustment Gas valve adjustment procedurePage

50-210 specifications

The Lochinvar 50-210 is a powerful and efficient boiler designed for residential and commercial heating applications. This model is a part of Lochinvar’s line of advanced heating solutions, known for their reliability, efficiency, and innovative technologies. The 50-210 offers a high thermal efficiency rating, ensuring that energy consumption is minimized while still providing excellent heating performance.

One of the standout features of the Lochinvar 50-210 boiler is its advanced control system. It is equipped with a user-friendly LCD display that allows easy access to system settings and real-time performance data. This technology enhances user experience, allowing for easy adjustments and monitoring, ensuring optimal performance based on specific heating needs.

The Lochinvar 50-210 is designed with a fully modulating burner, which means it can adjust its output to match the heating demand effectively. This feature not only provides superior comfort but also increases energy savings by preventing the boiler from running at full capacity when it's not necessary. Moreover, the modulating burner minimizes wear and tear, extending the lifespan of the unit.

In terms of safety, the Lochinvar 50-210 incorporates several features such as multiple temperature and pressure sensors, flame safeguard systems, and safety cut-off controls. These safeguard mechanisms ensure that the system operates safely and efficiently, providing peace of mind to users.

The construction of the Lochinvar 50-210 is robust, featuring high-grade stainless steel and a durable heat exchanger. This design helps resist corrosion, ensuring longevity and requiring minimal maintenance over the years. Additionally, its compact design allows for easier installation, making it suitable for various settings, even those with limited space.

Furthermore, the Lochinvar 50-210 operates quietly, which adds to its appeal for residential installations. Its environmental considerations are also noteworthy, with low emissions contributing to cleaner air quality.

Overall, the Lochinvar 50-210 is a sophisticated heating solution that blends efficiency, reliability, and advanced technology. With its user-friendly controls, modulating burner, safety features, and durable construction, it meets the heating demands of modern homes and commercial spaces, making it a top choice for those seeking dependable boiler performance.