Lochinvar 50-210 service manual Parameter table, Temperature Data

Page 15

Service Manual

1Service (continued)

Parameter table

Table 1D This table lists SMART SYSTEM control module parameters and where to access them

GENERAL

MENU

SUB ITEM

DESCRIPTION

SEE

USER ACCESS

INSTALLER ACCESS

PAGE

DISPLAY

MODIFY

DISPLAY

MODIFY

 

 

 

 

 

 

 

 

 

 

 

 

1

Boiler Model

17

Yes

No

Yes

No

 

 

 

 

 

 

 

 

 

2

User Code

17

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

3

Date and Time

17

Yes

Yes

Yes

Yes

A

 

 

 

 

 

 

 

4

Software Version

17

Yes

No

Yes

No

 

 

 

 

 

 

 

 

 

5

Temperature Units

17

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

6

Night Setback Temperature

17

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

7

Night Setback Times

17

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

TEMPERATURE

DATA

 

 

 

1

SH Set Point User

17

Yes

Yes

Yes

Yes

SETTING

 

 

 

 

 

 

 

 

 

 

 

2

SH Minimum Set Point

17

No

No

Yes

Yes

 

B

 

 

 

 

 

 

 

3

SH Maximum Set Point

17

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

SH Offset

17

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

5

SH Differential

18

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOGGING

 

 

1

Hours Running SH

18

Yes

No

Yes

No

 

 

 

 

 

 

 

 

 

 

2

Hours Running DHW

18

Yes

No

Yes

No

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

3

Ignition Attempts

18

Yes

No

Yes

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Show Last 10 Errors

18

Yes

No

Yes

No

 

 

 

 

 

 

 

 

 

 

SETTINGS

FUNCTIONS

DHW

 

1

Reset Last 10 Errors

18

No

No

Yes

Yes

D

 

 

 

 

 

 

 

2

Service Mode Delay

18

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

DHW Boiler Set Point

18

Yes

Yes

Yes

Yes

E

 

 

 

 

 

 

 

2

SH/DHW Switching Time

18

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

OUTDOOR RESETAIR

 

1

Minimum Air Temperature

18

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

2

Maximum Air Temperature

18

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

3

Maximum SH Set Point

19

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

4

Minimum SH Set Point

19

No

No

Yes

Yes

F

 

 

 

 

 

 

 

5

Outdoor Air Shutdown

19

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

6

Outdoor Air Shutdown

19

Yes

Yes

Yes

Yes

 

Differential

 

 

 

 

 

 

 

 

7

Shift Air Reset

19

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

8

Boost Temperature

20

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

9

Boost Time

20

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

15

Image 15
Contents Models 50 Contents Please read before proceeding Handling ceramic fiber materialsNiosh stated First Aid When servicing boiler Troubleshooting What is in this manual?Service MaintenanceNear boiler piping ServiceKnight wall mount display Control inputs Smart Control ModuleControl outputs Sequence of operation General OperationHow the boiler operates How the control module operatesOUT 123.8F129 Sequence of operationBLR SH 41% Rate Display panel menu access Display panel parameter access Parameter table Temperature DataControl Circulation Service Viewable and changeable control parameters Temperature settingsFunctions DHW settingsOutdoor air reset Data loggingOutdoor air shutdown Shift reset curveMaximum SH set point Minimum SH set pointAnti-cycling Boiler cascade address Control modesSH controlling sensor SH sourceService Notification Cascade offsetCirculation pumps Maintenance Maintenance and annual startup Service technicianOwner maintenance Maintenance Check boiler relief valve Flue vent system and air pipingCheck water system Check expansion tankInspect ignition and flame sense electrodes Check ignition ground wiringCheck all boiler wiring Check control settingsOiled bearing circulators Check flame signalCleaning boiler heat exchanger Review with ownerCheck the following TroubleshootingBefore troubleshooting Check control module fusesUnit Does Not No DisplayNo Burner OperationTemperature Resistance Checking temperature sensorsDHW Pump NoisyNo Pump Boiler Pump System PumpSequence Switch/LWCOFlow FlameNo Flame Ign Anti-cyclingRunning No FlameFan Speed Low Auto ResetHigh Limit Fan LowSensor Shorted Fan HighFan Speed High Sensor OpenTemp O/Shoot Rem Ctrl Flt Parameters ProgrOpen Low 24 vac Service BlkWatch Dog Error No Error StoredGas Supply Pressure Combustion Analysis ProcedureGas Valve Adjustment Or Obstruction2Gas Valve Adjustment Gas valve adjustment procedurePage

50-210 specifications

The Lochinvar 50-210 is a powerful and efficient boiler designed for residential and commercial heating applications. This model is a part of Lochinvar’s line of advanced heating solutions, known for their reliability, efficiency, and innovative technologies. The 50-210 offers a high thermal efficiency rating, ensuring that energy consumption is minimized while still providing excellent heating performance.

One of the standout features of the Lochinvar 50-210 boiler is its advanced control system. It is equipped with a user-friendly LCD display that allows easy access to system settings and real-time performance data. This technology enhances user experience, allowing for easy adjustments and monitoring, ensuring optimal performance based on specific heating needs.

The Lochinvar 50-210 is designed with a fully modulating burner, which means it can adjust its output to match the heating demand effectively. This feature not only provides superior comfort but also increases energy savings by preventing the boiler from running at full capacity when it's not necessary. Moreover, the modulating burner minimizes wear and tear, extending the lifespan of the unit.

In terms of safety, the Lochinvar 50-210 incorporates several features such as multiple temperature and pressure sensors, flame safeguard systems, and safety cut-off controls. These safeguard mechanisms ensure that the system operates safely and efficiently, providing peace of mind to users.

The construction of the Lochinvar 50-210 is robust, featuring high-grade stainless steel and a durable heat exchanger. This design helps resist corrosion, ensuring longevity and requiring minimal maintenance over the years. Additionally, its compact design allows for easier installation, making it suitable for various settings, even those with limited space.

Furthermore, the Lochinvar 50-210 operates quietly, which adds to its appeal for residential installations. Its environmental considerations are also noteworthy, with low emissions contributing to cleaner air quality.

Overall, the Lochinvar 50-210 is a sophisticated heating solution that blends efficiency, reliability, and advanced technology. With its user-friendly controls, modulating burner, safety features, and durable construction, it meets the heating demands of modern homes and commercial spaces, making it a top choice for those seeking dependable boiler performance.