Ariston 47-116-13, 41-116-01, 47-116-08. 47-116-09 Room Thermostat Connection

Page 15

2.10Room Thermostat Connection

In order to perform this procedure, remove the boiler casing as indicated in section 3.2. Then proceed as follows:

1Remove the two screws “A” in order to remove the cover, release the two clips “B” and lift and rotate down the control panel box.

2Open the cover “C” on the left hand side of the compartment.

3Insert the wire for the connection of the room thermostat into the cable clamp “D”, as indicated in photo 3.

1

B

 

A

2

 

3

D

C

4Remove the grommet “E” shown in the photo 4, make a hole in it and pass the room thermostat wire through.

5Remove the link located in the terminal block and connect the wire.

6Replace the grommet and the terminal block to their original positions, close the cover on the grommet compartment and fasten the wire-clamp “D” in place.

7If a remote time clock is to be fitted, disconnect the integral time clock plug from the P.C.B.

8Using a volt-free switching time clock, connect the switching wires from the time clock following points 1-6 above.

9If using a time clock and room thermostat, these must be connected in series as per points 1-8 above.

Note: Only a two-wire type room thermostat can be used.

For details on fitting the D.H.W. probe (Genus 27 RFFI only), please consult the separate instruction sheet supplied with the probe.

An anti-frost device is built-in to the appliance’s electronic regulation system.

4

E

5

6

D

B004

15

Image 15
Contents Leave These Instructions Adjacent to the GAS Meter Table of Contents General Information General InformationTechnical Information Overall View Genus 27 Rffi SystemInstallation Reference StandardsSiting the Appliance Clearances Overall DimensionsMounting the Appliance Electrical ConnectionGas Connection By-pass Safety Valve DischargeWater Connections View of the Boiler Connections Pipe WorkFilling Flue ConnectionsAir Release Points Mains Water Feed Central HeatingTower Flue Components 80 mm B004 KW 27 kW Exhaust/Air Maximum Extension Room Thermostat Connection Colours Electrical DiagramGenus 27 Rffi System CN202 Water Circuit Diagram Filling the Heating System CommissioningInitial Preparation Removing the CasingSummer/Winter/Flue Analysis Modes Control PanelChecks to be run before initial start-up are as follows Initial Start-up Operational AdjustmentsFume Discharge Monitoring Combustion AnalysisBoiler Safety Systems Changing the Type of Gas GAS AdjustmentsMaintenance Miscellaneous Wiring Diagram for Two Heating ZonesTypical Wiring Diagram for Connection to Ariston Unvented CylinderB004 B004 B004 Technical Service Hotline 01494

47-116-08. 47-116-09, 41-116-01, 47-116-13 specifications

Ariston has cemented its reputation as a pioneer in the realm of heating and hot water solutions, consistently delivering quality products that marry efficiency with performance. Among their impressive lineup, models like the Ariston 47-116-13, 41-116-01, 47-116-08, and 47-116-09 stand out due to their innovative technologies and user-centric designs.

One of the defining features of these Ariston models is their advanced heating technology, which efficiently delivers hot water while minimizing energy consumption. They utilize a robust insulation system that prevents heat loss, ensuring that water stays hot for longer periods. This not only enhances convenience but also contributes to lower energy bills.

The 47-116-13 model showcases Ariston's commitment to smart engineering with its built-in digital display. This feature allows users to monitor and adjust temperatures effortlessly, ensuring customized comfort. Additionally, the model is equipped with a sleek design, making it a stylish addition to any home setting.

The 41-116-01 model emphasizes user-friendliness through its intuitive controls and compact design, making it suitable for various installations, from small apartments to larger homes. Its lightweight construction facilitates easier handling and installation, further enhancing its appeal.

In contrast, the 47-116-08 model is designed with durability in mind, featuring a corrosion-resistant tank that promises longevity. This model also incorporates advanced heating elements that ensure rapid heating, allowing users to enjoy hot water whenever they need it.

Finally, the 47-116-09 resonates with environmentally conscious consumers, as it is designed to be energy-efficient while providing reliable performance. This model utilizes a smart control system that adapts to user habits, ensuring optimal energy usage without sacrificing comfort.

In summary, Ariston's 47-116-13, 41-116-01, 47-116-08, and 47-116-09 models exemplify the brand's dedication to creating high-performance, energy-efficient heating solutions. With features such as advanced heating technology, user-friendly controls, and durable materials, these models are ideal for anyone looking to enhance their hot water experience while enjoying significant cost savings and reduced environmental impact.