Ariston 41-116-01, 47-116-13, 47-116-08. 47-116-09 Electrical Diagram, Colours

Page 16

2.11Electrical Diagram

Legend:

AT

=

High Voltage P.C.B.

BT

=

Low Voltage P.C.B.

A= Remote Connector Kit

B= Flame Failure L.E.D.

C= Insufficient Water Pressure L.E.D.

D= Water Temperature Indicator L.E.D.s

E= Overheat Thermostat Warning L.E.D.

F= System Reset Button

G= Selector Knob for Operating Mode

H= Domestic Hot Water Temp. Adjustment

I= Central Heating Temp. Adjustment

J= Wire Connector for Room Thermostat

K= Connector for Total Check System

L= Selector for Local/Remote Control

M= Anti-cycling Device Adjustment for Heating

N= Soft-light Adjustment

O= Max Heating Temperature Adjustment

P= Time Clock Connection

Q= On/Off L.E.D.

R= On/Off Switch

S= Interface Wire for P.C.B.s

T= Relay Motorised Valve

U= Ignitor Relay

V= Gas Valve Relay

W= Fan Relay

X= Circulation Pump Relay

Y= Selector TCS2

Z= Link for Continuous Pump Run

Aa

=

Adaptor (British Gas use only)

A01

=

Air Pressure Switch

A02

=

Fan

A03

=

Gas Valve

A04

=

Ignitor

A05

=

Motorised Valve

A06

=

Circulation Pump

A07

=

Flame Detector

A08

=

Earth Terminal

A09

=

Flame Detection Circuit

A10

=

Flame Indicator L.E.D.

A11

=

Transformer

A12

=

Filter

B01

=

Over Heat Thermostat

B02

=

External Thermostat

B03

=

Gas Valve Modulator

B04

=

D.H.W. Probe Sensor Cylinder (RFFI SYSTEM models only)

B05

=

Heating Sensor

B06

=

Pressure Switch for Heating Circuit

B07

=

Microswitch for Diverter Valve (MFFI models only)

Colours

Gry

= Grey

Rd

= Red

Bl

= Blue

Grn/Yll

= Yellow/Green

Wh

= White

Brn

= Brown

Blk

= Black

Wh/Rd

= White/Red

16

B004

Image 16
Contents Leave These Instructions Adjacent to the GAS Meter Table of Contents General Information General InformationTechnical Information Genus 27 Rffi System Overall ViewReference Standards InstallationSiting the Appliance Overall Dimensions ClearancesElectrical Connection Mounting the ApplianceGas Connection Safety Valve Discharge Water Connections View of the Boiler ConnectionsPipe Work By-passFlue Connections Air Release PointsMains Water Feed Central Heating FillingTower Flue Components 80 mm B004 KW 27 kW Exhaust/Air Maximum Extension Room Thermostat Connection Electrical Diagram ColoursGenus 27 Rffi System CN202 Water Circuit Diagram Commissioning Initial PreparationRemoving the Casing Filling the Heating SystemControl Panel Summer/Winter/Flue Analysis ModesInitial Start-up Operational Adjustments Checks to be run before initial start-up are as followsCombustion Analysis Fume Discharge MonitoringBoiler Safety Systems GAS Adjustments Changing the Type of GasMaintenance Wiring Diagram for Two Heating Zones MiscellaneousWiring Diagram for Connection to Ariston Unvented Cylinder TypicalB004 B004 B004 Technical Service Hotline 01494

47-116-08. 47-116-09, 41-116-01, 47-116-13 specifications

Ariston has cemented its reputation as a pioneer in the realm of heating and hot water solutions, consistently delivering quality products that marry efficiency with performance. Among their impressive lineup, models like the Ariston 47-116-13, 41-116-01, 47-116-08, and 47-116-09 stand out due to their innovative technologies and user-centric designs.

One of the defining features of these Ariston models is their advanced heating technology, which efficiently delivers hot water while minimizing energy consumption. They utilize a robust insulation system that prevents heat loss, ensuring that water stays hot for longer periods. This not only enhances convenience but also contributes to lower energy bills.

The 47-116-13 model showcases Ariston's commitment to smart engineering with its built-in digital display. This feature allows users to monitor and adjust temperatures effortlessly, ensuring customized comfort. Additionally, the model is equipped with a sleek design, making it a stylish addition to any home setting.

The 41-116-01 model emphasizes user-friendliness through its intuitive controls and compact design, making it suitable for various installations, from small apartments to larger homes. Its lightweight construction facilitates easier handling and installation, further enhancing its appeal.

In contrast, the 47-116-08 model is designed with durability in mind, featuring a corrosion-resistant tank that promises longevity. This model also incorporates advanced heating elements that ensure rapid heating, allowing users to enjoy hot water whenever they need it.

Finally, the 47-116-09 resonates with environmentally conscious consumers, as it is designed to be energy-efficient while providing reliable performance. This model utilizes a smart control system that adapts to user habits, ensuring optimal energy usage without sacrificing comfort.

In summary, Ariston's 47-116-13, 41-116-01, 47-116-08, and 47-116-09 models exemplify the brand's dedication to creating high-performance, energy-efficient heating solutions. With features such as advanced heating technology, user-friendly controls, and durable materials, these models are ideal for anyone looking to enhance their hot water experience while enjoying significant cost savings and reduced environmental impact.