Ariston 41-116-01, 47-116-13, 47-116-08. 47-116-09 installation instructions Technical Information

Page 4

3- Check the general condition of the appliance and of the combustion chamber visually.

4- Visual check of the combustion: clean burners if necessary.

5- With reference to point 3, dismantle and clean the combustion chamber if necessary.

6- With reference to point 4, dismantle and clean the injectors if necessary.

7- Visual check of the primary heat exchanger:

-check for overheating of the exchangers fins;

-clean the exhaust side of the exchanger and fan if necessary.

8- Regulate the gas pressure, ignition pressure, partial flame, maximum flame.

9- Check proper operation of the heating safety system:

-maximum safety temperature;

-maximum safety pressure.

10- Check the proper operation of the gas safety system:

-gas or flame safety device;

-gas valve safety device.

11- Check that the electrical connections have been made in compliance with the instructions shown in the Installation Instructions.

12- Check the efficiency of the hot water supply (flow and temperature).

13- Check general operation of the appliance.

14- Check the exhaust system for the combustion products.

1.2Technical Information

 

 

 

23 MFFI

27 MFFI

27 RFFI SYSTEM

30 MFFI

 

 

 

 

 

 

 

CE Certification

 

 

 

 

 

 

Heat Input

max/min

kW

25.6/11.0

29.8/12.0

29.8/12.0

33.0/12.0

Heat Output

max/min

kW

23.1/9.2

27.3/10.1

27.3/10.1

30.3/10.2

Efficiency of Nominal Heat Input

%

 

90.2

91.6

91.6

92.0

Efficiency at 30% of Nominal Heat Input

%

 

87.8

88.3

88.3

88.6

Heat Loss to the Casing (³T=50°C)

%

 

1.2

1.3

1.3

1.4

Flue Heat Loss with Burner Operating

%

 

8.6

7.1

7.1

6.6

Flue Heat Loss with Burner Off

%

 

0.4

0.4

0.4

0.4

Maximum Discharge of Fumes (G20-G25)

Kg/h

 

59

62

62

61

Residual Discharge Head

mbar

 

1.15

1.4

1.4

1.4

Consumption at Nominal Capacity (G20-G25)

m3/h

 

2.72/3.32

3.16/3.86

3.16/3.86

3.49/4.05

Gas Consumption after 10 Minutes*

m3

 

0.32/0.39

0.37/0.45

0.37/0.45

0.41/0.47

(15°C, 1013 mbar) (G30-G31)

Kg/h

 

2.02/2.00

2.35/2.32

2.35/2.32

2.60/2.57

Temp. of exhaust fumes at nominal

 

 

 

 

 

 

capacity (G20-G25)

°C

 

137

128

128

135

CO2 Content

%

 

5.8

6.6

6.6

7.5

O2 Content

%

 

9.2

8.0

8.0

8.0

CO Content

ppm

 

32

34

34

49

Minimum Ambient Temperature

°C

 

+5

+5

+5

+5

Head Loss on Water Side (max) (³T=20°C)

mbar

 

200

200

200

200

Residual Head of System

bar

 

0.25

0.25

0.25

0.25

Heating Temperature

max/min °C

82/42

82/42

82/42

82/42

Domestic Hot Water Temperature

max/min

°C

56/36

56/36

---

56/36

D.H.W. Flow Rate ³T=35°C

l/min

 

9.5

11.2

---

12.3

D.H.W. Flow Rate ³T=35°C

gal/min

 

2.1

2.5

---

2.7

D.H.W. Flow Minimum Rate

l/min

 

2.6

2.6

---

2.6

Pressure of Domestic Hot Water

max/min bar

6/0.2

6/0.2

---

6/.02

Expansion Vessel Capacity

l

 

7

7

7

7

Expansion Vessel Pre-load Pressure

bar

 

1

1

1

1

Maximum Water Content in System

l

 

145

145

145

145

Maximum Heating Pressure

bar

 

3

3

3

3

Nominal Pressure Natural Gas (G20-G25)

mbar

 

20-25

20-25

20-25

20-25

Liquid Gas (G30-G31)

mbar

 

30-37

30-37

30-37

30-37

Electrical Supply

V/Hz

 

230 / 50

230 / 50

230 / 50

230 / 560

Power Consumption

W

 

150

190

190

190

Protection Grade of Electrical System

IP

 

X4D

X4D

X4D

X4D

Internal Fuse Rating

 

 

FAST 2 AT

FAST 2 AT

FAST 2 AT

FAST 2 AT

Weight

Kg

 

47

47

46.5

47

G.C. Number

47-116-08

47-116-09

41-116-01

47-116-13

*Calculated at 70% maximum output

4

B004

Image 4
Contents Leave These Instructions Adjacent to the GAS Meter Table of Contents General Information General InformationTechnical Information Genus 27 Rffi System Overall ViewReference Standards InstallationSiting the Appliance Overall Dimensions ClearancesElectrical Connection Mounting the ApplianceGas Connection Safety Valve Discharge Water Connections View of the Boiler ConnectionsPipe Work By-passFlue Connections Air Release PointsMains Water Feed Central Heating FillingTower Flue Components 80 mm B004 KW 27 kW Exhaust/Air Maximum Extension Room Thermostat Connection Electrical Diagram ColoursGenus 27 Rffi System CN202 Water Circuit Diagram Commissioning Initial PreparationRemoving the Casing Filling the Heating SystemControl Panel Summer/Winter/Flue Analysis ModesInitial Start-up Operational Adjustments Checks to be run before initial start-up are as followsCombustion Analysis Fume Discharge MonitoringBoiler Safety Systems GAS Adjustments Changing the Type of GasMaintenance Wiring Diagram for Two Heating Zones MiscellaneousWiring Diagram for Connection to Ariston Unvented Cylinder TypicalB004 B004 B004 Technical Service Hotline 01494

47-116-08. 47-116-09, 41-116-01, 47-116-13 specifications

Ariston has cemented its reputation as a pioneer in the realm of heating and hot water solutions, consistently delivering quality products that marry efficiency with performance. Among their impressive lineup, models like the Ariston 47-116-13, 41-116-01, 47-116-08, and 47-116-09 stand out due to their innovative technologies and user-centric designs.

One of the defining features of these Ariston models is their advanced heating technology, which efficiently delivers hot water while minimizing energy consumption. They utilize a robust insulation system that prevents heat loss, ensuring that water stays hot for longer periods. This not only enhances convenience but also contributes to lower energy bills.

The 47-116-13 model showcases Ariston's commitment to smart engineering with its built-in digital display. This feature allows users to monitor and adjust temperatures effortlessly, ensuring customized comfort. Additionally, the model is equipped with a sleek design, making it a stylish addition to any home setting.

The 41-116-01 model emphasizes user-friendliness through its intuitive controls and compact design, making it suitable for various installations, from small apartments to larger homes. Its lightweight construction facilitates easier handling and installation, further enhancing its appeal.

In contrast, the 47-116-08 model is designed with durability in mind, featuring a corrosion-resistant tank that promises longevity. This model also incorporates advanced heating elements that ensure rapid heating, allowing users to enjoy hot water whenever they need it.

Finally, the 47-116-09 resonates with environmentally conscious consumers, as it is designed to be energy-efficient while providing reliable performance. This model utilizes a smart control system that adapts to user habits, ensuring optimal energy usage without sacrificing comfort.

In summary, Ariston's 47-116-13, 41-116-01, 47-116-08, and 47-116-09 models exemplify the brand's dedication to creating high-performance, energy-efficient heating solutions. With features such as advanced heating technology, user-friendly controls, and durable materials, these models are ideal for anyone looking to enhance their hot water experience while enjoying significant cost savings and reduced environmental impact.