Ariston 41-116-01, 47-116-13, 47-116-08. 47-116-09 Initial Start-up Operational Adjustments

Page 22

3.4Initial Start-up

3.5Operational Adjustments

The checks to be run before initial start-up are as follows:

1.Make sure that:

-the screw on the automatic air valve has been loosened when the system is full;

-If the water pressure in the system is below 1 bar, bring it up to the appro- priate level;

-Check to see whether the gas cock is closed;

-Make sure that the electrical connection has been made properly and that the earth wire is connected to an efficient earthing system;

-Supply power to the boiler by pressing the On/Off switch <L> - the L.E.D. “I” will turn on - turn the selector knob “C” to the < winter> setting. This will start the circulation pump. After 7 seconds, the boiler will signal a shut- down due to failure ignition. Leave the boiler as it is until all of the air has been bled from the lines.

-Loosen the cap on the head of the pump to eliminate any air pockets;

-Repeat the procedure for bleeding the radiators of air;

-Open the taps for a brief period;

-Check the system pressure and, if it has dropped, open the filling loop again to bring the pressure back up to 1 bar.

2.Check the exhaust flue for the fumes produced by combustion.

3.Make sure that all gate valves are open;

4.Turn on the gas cock and check the seals on the connections, including the one for the burner, making sure that the meter does not signal the passage of gas. Check the connections with a soap solution and eliminate any leaks.

5.Press the reset button “A” for the lighting system; the spark will light the main burner. If the burner does not light the first time, repeat the procedure.

6.Check the minimum and maximum pressure values for the gas going to the burner; adjust it if needed using the values indicated in the table in section 4.

(See sect of the servicing manual).

The boiler was designed to make regulation easy. To access the adjustment and control area, simply remove the cover by unscrewing the screws “A” and “C” and lift up the small service panels “B1” and “B2” respectively. The first provides access to the control (low voltage) P.C.B., while the second makes it possible to work on the power supply P.C.B.

A

B1

B2

 

C

The service panel “B2” also provides access to:

-the power supply cord connector;

-the fuses;

-the selector knob for continuous operation of the circulation pump.

The service panel “B1” also provides access to:

-the potentiometer for regulating the ignition delay (anti-cycling) feature, which can be set from 0 to 2 minutes (factory set at 1 minute);

22

B004

Image 22
Contents Leave These Instructions Adjacent to the GAS Meter Table of Contents General Information General InformationTechnical Information Genus 27 Rffi System Overall ViewReference Standards InstallationSiting the Appliance Overall Dimensions ClearancesElectrical Connection Mounting the ApplianceGas Connection Pipe Work Safety Valve DischargeWater Connections View of the Boiler Connections By-passMains Water Feed Central Heating Flue ConnectionsAir Release Points FillingTower Flue Components 80 mm B004 KW 27 kW Exhaust/Air Maximum Extension Room Thermostat Connection Electrical Diagram ColoursGenus 27 Rffi System CN202 Water Circuit Diagram Removing the Casing CommissioningInitial Preparation Filling the Heating SystemControl Panel Summer/Winter/Flue Analysis ModesInitial Start-up Operational Adjustments Checks to be run before initial start-up are as followsCombustion Analysis Fume Discharge MonitoringBoiler Safety Systems GAS Adjustments Changing the Type of GasMaintenance Wiring Diagram for Two Heating Zones MiscellaneousWiring Diagram for Connection to Ariston Unvented Cylinder TypicalB004 B004 B004 Technical Service Hotline 01494

47-116-08. 47-116-09, 41-116-01, 47-116-13 specifications

Ariston has cemented its reputation as a pioneer in the realm of heating and hot water solutions, consistently delivering quality products that marry efficiency with performance. Among their impressive lineup, models like the Ariston 47-116-13, 41-116-01, 47-116-08, and 47-116-09 stand out due to their innovative technologies and user-centric designs.

One of the defining features of these Ariston models is their advanced heating technology, which efficiently delivers hot water while minimizing energy consumption. They utilize a robust insulation system that prevents heat loss, ensuring that water stays hot for longer periods. This not only enhances convenience but also contributes to lower energy bills.

The 47-116-13 model showcases Ariston's commitment to smart engineering with its built-in digital display. This feature allows users to monitor and adjust temperatures effortlessly, ensuring customized comfort. Additionally, the model is equipped with a sleek design, making it a stylish addition to any home setting.

The 41-116-01 model emphasizes user-friendliness through its intuitive controls and compact design, making it suitable for various installations, from small apartments to larger homes. Its lightweight construction facilitates easier handling and installation, further enhancing its appeal.

In contrast, the 47-116-08 model is designed with durability in mind, featuring a corrosion-resistant tank that promises longevity. This model also incorporates advanced heating elements that ensure rapid heating, allowing users to enjoy hot water whenever they need it.

Finally, the 47-116-09 resonates with environmentally conscious consumers, as it is designed to be energy-efficient while providing reliable performance. This model utilizes a smart control system that adapts to user habits, ensuring optimal energy usage without sacrificing comfort.

In summary, Ariston's 47-116-13, 41-116-01, 47-116-08, and 47-116-09 models exemplify the brand's dedication to creating high-performance, energy-efficient heating solutions. With features such as advanced heating technology, user-friendly controls, and durable materials, these models are ideal for anyone looking to enhance their hot water experience while enjoying significant cost savings and reduced environmental impact.