Chromalox CES-6 manual Renewal Parts Identification, Part Description Part Number

Page 19

RENEWAL PARTS IDENTIFICATION

Part Description

 

Part Number

GAUGE GLASS ASSEMBLIES, CHECK VALVES & SIGHT GLASSES

Check Valve 1/2” CES-6 through CES-18

 

344-118536-053

Check Valve 3/4” CES-24 through CES-180

 

344-118536-054

Gauge Glass Assembly Valves (O-ring gaskets included)

 

344-120970-002

Protector Rods (2 required) CES-6 through CES-18

 

242-121047-008

Protector Rods (2 required) CES-24 through CES-72

 

242-121047-001

Protector Rods (2 required) CES-100 through CES-180

 

242-121047-009

O-Ring Gaskets (2 Required)

 

132-073284-001

Pyrex Glass 2 “O” Ring Gaskets 7 3/4”

 

 

CES-6 through CES-18

 

374-121046-011

Pyrex Glass 2 “O” Ring Gaskets 9 3/4”

 

 

CES-24 through CES-72

 

374-121046-012

Pyrex Glass 2 “O” Ring Gaskets 11 3/4”

 

 

 

 

 

SAFETY VALVE

 

CES-120 through CES-100

 

374-121046-014

15 psig 1/2” CES-6 through CES-36

 

344-300032-001

15 psig 3/4” CES-48 through CES-72

 

344-300032-017

15 psig 1 1/2” CES-100 through CES-180

 

344-300032-040

30 psig 1/2” CES-6 through CES-60

 

344-300032-002

30 psig 3/4” CES-72

 

344-300032-018

30 psig 1” CES-100 through CES-180

 

344-300032-035

50 psig 1/2” CES-6 through CES-72

 

344-300032-003

50 psig 1” CES-100 through CES-180

 

344-300032-036

 

 

 

PRESSURE CONTROLS & SEQUENCES

 

100 psig 1/2” CES-6 through CES-72

 

344-300032-004

100 psig 3/4” CES-160 through CES-180

 

344-300032-020

Operating Pressure Controls 10-100 psi

 

292-300031-001

Hi-Limit Control Manual Reset 90 psi

 

292-300031-002

 

 

 

LOW WATER CUTOFF & PUMP CONTROLS

 

5-Step Solid State Sequencer

 

323-300107-015

10-Step Solid State Sequencer

 

323-300107-015

Siphon Tube for Pressure Controls

 

215-300026-002

MM-150 Control Complete (Auto Reset)

 

292-300065-001

MM-150M Control Complete (Manual Reset)

 

292-300065-002

Float and Rod for MM-150 & MM-150M

 

292-300065-102

Complete Head Mechanism (Auto Reset)

 

292-300065-100

Complete Head Mechanism (Manual Reset)

 

292-300065-101

Head Gasket

 

292-300065-103

3 Wire Cut-off & Alarm Switch (Auto Reset)

 

292-300065-104

3 Wire Cut-off & Alarm Switch (Manual Reset)

 

292-300065-105

2 Wire Pump Switch

 

292-300065-106

Bellows Base Clamp & Bellows Assembly (Auto Reset)

 

292-300065-108

Bellows Base Clamp & Bellows Assembly (Manual Reset)

 

292-300065-109

 

 

CONTROL VOLTAGE TRANSFORMERS (120V SECONDARY)

Bellows Base Gasket

 

292-300065-110

Bellows Base Clamp Assembly (Auto Reset)

 

292-300065-111

Bellows Base Clamp Assembly (Manual Reset)

 

292-300065-112

 

 

 

LOW PRESSURE WATER FEED (ES-99117)

 

Bellows Base Assembly with Gasket

 

292-300065-113

 

 

CORROSION RESISTANT ELEMENTS & GASKETS

1KVA 208V Primary

 

315-300088-020

1KVA 240/480V Primary

 

315-300088-021

1 1/2 KVA 208V Primary

 

315-300088-025

1 1/2 KVA 240/480V Primary

 

315-300088-026

Solenoid Valve

 

344-121780-002

Strainer

 

351-118664-001

THREE PHASE

 

 

12kW 208V

 

155-554735-044

12kW 240V

 

155-554735-032

12kW 480V

 

155-554735-015

17kW 208V

 

155-554735-048

17kW 240V

 

155-554735-028

17kW 480V

 

155-554735-016

Gasket

 

132-146012-011

 

 

 

Part Description

 

Part Number

COLD WATER INJECTION PUMPS (0-100 PSIG)

 

Motor and Pump used in ES-38002

 

226-300177-001

Motor and Pump used in ES-38020

 

226-300177-004

Pump only used in ES-38002

 

226-300173-001

Pump only used in ES-38020

 

226-300173-004

Motor only used in ES-38002 115V 60Hz

 

193-300175-001

Motor only used in ES-38002 230V 50Hz

 

193-300175-002

Motor only used in ES-38020 115V 60Hz

 

193-300175-004

Strainer used in ES-38020

 

351-118664-001

V-Band Mount used in ES-38002 & ES-38020

 

355-300174-001

Solenoid Valve used in ES-38002 & ES-38020

 

344-121780-002

Hose Assembly 18” Long used in ES-38002 & ES-38020

 

349-300181-002

Pump Base

 

015-300125-001

Adapter for Hose used in ES-38002

 

001-300180-001

 

 

 

CONDENSATE RETURN SYSTEMS

 

 

Adapter for Hose used in ES-38020

 

001-300180-002

Pump and Motor Assembly used in ES-38083V 26 Gal

 

226-300172-003

Pump and Motor Assembly used in ES-38084V 33 Gal

 

226-300172-006

Condensate Tank only used in ES-38083V 26 Gal

 

226-300218-001

Condensate Tank only used in ES-38084V 33 Gal

 

226-300218-002

Parts Common to both 26 & 33 Gal. Systems

 

 

Impeller Raceway for Pump

 

226-118671-001

Seal for Pump

 

251-118657-002

“O” Ring

 

251-118657-003

Float Valve Assembly (Float Valve & Stem)

 

344-300223-006

Disc Cover Assembly (Less Float Valve)

 

101-300220-001

Gasket for Disc Cover

 

132-300224-001

Frame Assembly (Less Tank)

 

126-300221-001

Strainer 1” NPT

 

351-118664-019

Gauge Glass Valve Set

 

344-120970-002

Gauge Glass

 

374-121046-011

Gauge Glass Protector Rods (2 Required)

 

242-121047-008

Manual Valve

 

344-121194-002

Sight Glass Assembly

 

130-073287-004

Drain Valve

 

344-121194-006

 

 

AUX LOW WATER CUT-OFF (OPTIONAL EQUIPMENT)

Probe Spark Plug

346-300035-001

Aux Low Water Cut-off Board with Relay

323-300033-016

Aux Low Water Cut-off Board Without Relay

323-300033-017

Relay for Aux Low Cut-off Board

072-300047-003

Probe 7 15/16” CES 6-20

242-300036-019

Probe 9 1/2” CES 24-72

242-300036-002

 

 

 

MISCELLANEOUS PARTS

 

Probe 10 15/16” CES-100 through CES-180

242-300036-017

ON-OFF Switch with Pilot Light

292-053223-002

Control Circuit Fuse

128-072576-027

Control Circuit Terminal Block 4 Pole 250V 20AMP

303-075443-003

Control Circuit Fuse Block

129-300029-001

Blank Flange

121-300199-001

Element Gasket

132-146012-011

AUTO BLOWDOWN PARTS

 

Stainless Steel Bolts (6 required) for Element

345-072565-428

Vacuum Breaker Assembly

344-300149-001

Motorized Valve 1/2” CES-6 through CES-18

344-300089-002

Motorized Valve 1” CES-24 through CES-180

344-300089-005

Timer

292-300101-002

Relay SPST No. 2

072-300072-002

Relay Interval Delay .6-60 Sec. 3

072-300148-003

Switch Momentary Contact DPDT 4

292-300146-001

Switch Rocker SPDT 5

272-300147-001

Pilot Light Red 6

213-300145-001

Terminal Block 4 Pole

303-075444-003

Terminal Block 5 Pole

303-075444-004

Fuse Block 30A

129-024494-001

Fuse 15A

128-121133-072

Motorized Ball Valve (Size 1/2)

344-300089-001

Motorized Ball Valve (Size 1/2)

344-300089-002

Motorized Ball Valve (Size 1/2)

344-300089-003

Motorized Ball Valve (Size 1)

344-300089-004

Motorized Ball Valve (Size 1)

344-300089-005

HONEYWELL PRESSURE CONTROLS

 

Motorized Ball Valve (Size 1)

344-300089-006

Operating Pressure Control 2-15 psi

292-300038-001

Hi-Limit Control (Manual Reset) 15 psi

292-300038-005

Proportional Pressure Control 2-15 psi

292-300039-001

Operating Pressure Control 5-50 psi

292-300038-002

Hi-Limit Control (Manual Reset) 50 psi

292-300038-006

Proportional Pressure Control 2-50 psi

292-300039-002

Operating Pressure Control 10-150 psi

292-300038-003

Hi-Limit Control (Manual Reset) 90 psi

292-300038-007

Proportional Pressure Control 5-150 psi

292-300039-003

 

 

 

19

Image 19
Contents Chromalox Model CES-6 through CES-18 DimensionsModel InstallationBoiler 208 240 480 WiringTypical Wiring Diagrams DiagramBoilers under 40 Amps total not fused Black Diagram Diagram Black Brown Blue White Miller LOW Water Cutoff Control PRE-OPERATION CheckHigh Limit Pressure Control Operation Adjusting Operating Pressure ControlsRecommended START-UP Procedures OperationIf Furnished Automatic Blowdown InstructionsOptional Equipment for Steam Boilers Solid State Progressive Sequencer Boiler Sequence Solid StateHigh Pressure Feed Pump Motor DimensionsWater Feed Systems LOW Pressure FeedSequence MaintenanceInstallation Wiring PlumbingMaintenance Immersion Heater Failure Causes Part Description Part Number Renewal Parts IdentificationValves & Gauges Limited Warranty

CES-6 specifications

The Chromalox CES-6 is a state-of-the-art electric heating solution designed for industrial and commercial applications. This versatile unit offers a range of features that enhance its efficiency, durability, and ease of use. With a focus on advanced technology, the CES-6 is engineered to meet the demands of various heating requirements, from process heating to temperature maintenance.

One of the standout features of the CES-6 is its robust construction. Built to withstand harsh environments, it is made from high-quality materials that ensure longevity and reliability. The unit's enclosure is resistant to moisture and dust, making it ideal for applications in challenging conditions. This durability ensures that the CES-6 can operate effectively in settings such as manufacturing plants, warehouses, and outdoor installations.

The CES-6 leverages cutting-edge heating technologies, including advanced thermal management systems. This feature allows for precise temperature control, ensuring optimal performance and energy efficiency. By utilizing programmable temperature settings, users can customize their heating profiles to match specific operational needs, reducing energy consumption and operating costs.

Another significant characteristic of the CES-6 is its ease of installation and maintenance. Designed with user convenience in mind, the unit comes equipped with adaptable mounting options and user-friendly interfaces. This makes it straightforward for technicians to install and service, minimizing downtime and enhancing productivity.

Safety is a top priority with the CES-6, which incorporates multiple safety features to protect users and equipment. Over-temperature protection, built-in alarm systems, and fail-safe mechanisms are just a few of the safeguards included. These features not only enhance user safety but also contribute to the overall integrity of the heating process.

In conclusion, the Chromalox CES-6 stands out in the market for its combination of durability, advanced technology, and user-friendly design. Its robust construction makes it suitable for demanding industrial settings, while its energy-efficient heating capabilities and ease of installation ensure it meets the needs of a wide range of applications. Whether you are looking for reliable heating for your manufacturing processes or need a dependable solution for temperature maintenance, the CES-6 is an exceptional choice that delivers performance and efficiency.