Kenmore 153.33096 Filling the Water Heater, Venting, Local gas supplier for further information

Page 15

The temperature-pressure relief valve must be manually operated at least once a year. Caution should be taken to ensure that

(1)no one is in front of or around the outlet of the temperature- pressure relief valve discharge line, and (2) the water manually discharged will not cause any bodily injury or property damage because the water may be extremely hot.

If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the cold water inlet to the water heater, follow the draining instructions, and replace the temperature-pressure relief valve with a new one.

Filling the Water Heater

Never use this water heater unless it is completely full of water. To prevent damage to the tank, the tank must be filled with water. Water must flow from the hot water faucet before turning “ON” gas to the water heater.

To fill the water heater with water:

Close the water heater drain valve by inserting a flat head screwdriver in the slot on the stem and turn to the right (clockwise). The drain valve is on the lower front of the water heater.

Open the cold water supply valve to the water heater.

NOTE: The cold water supply valve must be left open when the water heater is in use.

To insure complete filling of the tank, allow air to exit by opening the nearest hot water faucet. Allow water to run until a constant flow is obtained. This will let air out of the water heater and the piping.

Check all water piping and connections for leaks. Repair as needed.

Venting

VENT DAMPERS - Any vent damper, whether it is operated thermally or otherwise must be removed if its use inhibits proper drafting of the water heater.

Thermally Operated Vent Dampers: Gas-fired water heaters having thermal efficiency in excess of 80% may produce a relatively low flue gas temperature. Such temperatures may not be high enough to properly open thermally operated vent dampers. This would cause spillage of the flue gases and may cause carbon monoxide poisoning.

Vent dampers must bear evidence of certification as complying with the current edition of the American National Standard

ANSI Z21.68 (ANSI Z21.66 & 67, respectively, cover electrically and mechanically actuated vent dampers). Before installation of any vent damper, consult your local Sears Service Center or

the local gas supplier for further information.

To insure proper venting of this gas-fired water heater, the correct vent pipe diameter must be utilized. Any additions or deletions of other gas appliances on a common vent with this water heater may adversely affect the operation of the water heater. Consult your gas supplier if any such changes are planned. For replacement heater installations where pre-existing venting is used, the venting must be inspected for obstructions and if deterioration is present, it must be replaced.

For proper venting in certain installations, a larger diameter vent pipe may be necessary. Consult your local Sears Service Center or gas supplier to aid you in determining the proper venting for your water heater from the vent tables in the current edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54.

Periodically check the venting system for signs of obstruction or deterioration and replace if needed.

The combustion and ventilation air flow must not be obstructed.

The water heater with draft hood installed must be connected to a chimney or listed vent pipe system, which terminates to the outdoors. Never operate the water heater unless it is vented to the outdoors and has adequate air supply to avoid risks of improper operation, explosion or asphyxiation.

For proper draft hood attachment, the draft hood legs may be angled slightly inward.

Place the draft hood legs in the receiving holes on the top of the water heater. The legs will snap in the holes to give a tight fit. Secure the legs to top with sheet metal screws. See Figure 17.

Place the vent pipe over the draft hood. With the vent pipe in position, drill a small hole through both the vent pipe and draft hood. Secure them together with a sheet metal screw.

Obstructed or deteriorated vent systems may present serious health risk or asphyxiation.

15

Image 15
Contents Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A GAS Water HeaterSears, Roebuck and Co Safe INSTALLATION, USE and ServiceSafety Precautions Table of Contents Customer Responsibilities Product SpecificationsBasic Tools Additional Tools Needed When Sweat SolderingMaterials and Basic Tools Needed Materials NeededPilot & Main Burner Typical InstallationTurn OFF the gas supply to the water heater Installation InstructionsInstallation is Completed, see Removing the Old Water HeaterFacts to Consider About the Location Insulation Blankets See on page 10 and below ALL AIR from Inside BuildingsHotter Water can Scald Water PipingValve and Pipe Insulation Temperature-Pressure Relief Valve Filling the Water Heater VentingLocal gas supplier for further information Gas Piping Sediment Traps GAS Piping with Flexible ConnectorOperating Instructions Settings Temperature RegulationBurner Inspection Service and AdjustmentTank Sediment Cleaning Vent System InspectionRemoving the Burner Door Assembly Replacing the Pilot AssemblyUltra Low NOx Natural Gas Burner Replacing the Thermocouple External Inspection & Cleaning of the Flame ArrestorCleaning the Pilot Assembly Cleaning the Combustion Chamber and Flame ArrestorReplacing the Burner Door Assembly Testing the Igniter SystemPiezoelectric Igniter System Removing and Replacing the Gas Control Valve/Thermostat HousekeepingAnode Rod Inspection Draining Temperature-Pressure Relief Valve OperationDrain Valve Washer Replacement ServiceStart Up Conditions Troubleshooting GuideCondensation Operational ConditionsPilot will not Light RecoveryBurner will not Ignite Smelly WaterCombustion Odors Drip from Relief ValveThermostat Fails to Shut OFFSection a Pilot light will not light Pilot Light Troubleshooting Chart153.330960 Gallon 153.330970 Parts Order ListMY-HOME

153.33097, 153.33096 specifications

Kenmore has long been a trusted name in home appliances, and their washer models 153.33096 and 153.33097 are no exception. These machines stand out for their modern features, advanced technology, and user-friendly characteristics that cater to the needs of today’s households.

One of the main features of both models is their efficient cleaning performance. The machines are equipped with a powerful wash system that ensures thorough dirt and stain removal, even from heavily soiled fabrics. The dual-action agitator in each model enhances the washing process by allowing optimal movement of laundry, resulting in cleaner clothes in less time.

In terms of capacity, the Kenmore 153.33096 and 153.33097 offer a generous wash drum size, accommodating large loads. This is particularly convenient for families or individuals who do laundry less frequently. The higher capacity not only saves time between cycles but also reduces water and energy consumption, making these washers environmentally friendly options.

The models feature various wash cycles and temperature settings to suit different fabric types and soiling levels. Users can select from options like delicate, heavy-duty, and quick wash cycles, providing flexibility for various laundry needs. This versatility is further enhanced by the inclusion of a digital display and intuitive controls, making it easy to customize each wash.

Another key characteristic of the 153.33096 and 153.33097 is the incorporation of advanced technology. The machines utilize a smart sensor system that detects load sizes and automatically adjusts water levels accordingly. This feature not only conserves water but also ensures optimal cleaning performance for every load.

Noise reduction technology is also a significant advantage of these Kenmore models. Using advanced sound-dampening materials, they operate quietly, making them a desirable choice for any household, especially in open-plan living spaces.

In summary, the Kenmore 153.33096 and 153.33097 washers are exemplary products that combine performance, efficiency, and user-friendly design. With their robust features, advanced technologies, and thoughtful characteristics, they deliver an exceptional laundry experience that meets the demands of modern life. Whether you're dealing with everyday laundry or specialized items, these Kenmore models offer tailored solutions to ensure outstanding cleanliness and convenience.