Kenmore 153.33097, 153.33096 owner manual Gas Piping

Page 16

FIGURE 17.

The vent pipe from the water heater must be no less than the diameter of the draft hood outlet on the water heater and must slope upward at least 1/4 inch per linear foot (21 mm per meter). See Figure 18.

FIGURE 18.

All vent gases must be completely vented to the outdoors of the structure (dwelling). Install only the draft hood provided with the new water heater and no other draft hood.

Vent pipes must be secured at each joint with sheet metal screws.

There must be a minimum of 6 inches (153 mm) clearance between single wall vent pipe and any combustible material. Fill and seal any clearance between single wall vent pipe and combustible material with mortar mix, cement, or other noncombustible substance. For other than single wall, follow vent pipe manufacturer’s clearance specifications. To insure a tight fit of the vent pipe in a brick chimney, seal around the vent pipe with mortar mix cement.

Failure to have required clearances between vent piping and combustible material will result in a fire hazard.

Be sure vent pipe is properly connected to prevent escape of dangerous flue gases which could cause deadly asphyxiation.

Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach and process chemicals are typical compounds which are potentially corrosive.

Gas Piping

Make sure the gas supplied is the same type listed on the model rating plate. The inlet gas pressure must not exceed 14 inch water column (3.5kPa) for natural and propane gas (L.P.) gas. The minimum inlet gas pressure listed on the rating plate is for the purpose of input adjustment. If the gas control valve is subjected to pressures exceeding 1/2 pound per square inch (3.5kPa), the damage to the gas control valve could result in a fire or explosion from leaking gas.

If the main gas line shutoff serving all gas appliances is used, also turn “OFF” the gas at each appliance. Leave all gas appliances shut “OFF” until the water heater installation is complete.

A gas line of sufficient size must be run to the water heater. Consult the current edition of National Fuel Gas Code ANSI Z223.1/NFPA 54 and your gas supplier concerning pipe size.

There must be:

A readily accessible manual shut off valve in the gas supply line serving the water heater.

A drip leg (sediment trap) ahead of the gas control valve to help prevent dirt and foreign materials from entering the gas control valve.

A flexible gas connector or a ground joint union between the shut off valve and control valve to permit servicing of the unit.

Be sure to check all the gas piping for leaks before lighting the water heater. Use a soapy water solution, not a match or open flame. Rinse off soapy solution and wipe dry.

The minimum inlet gas pressure shown on the rating plate is that which will permit firing at the rated input.

16

Image 16
Contents GAS Water Heater Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.ASafe INSTALLATION, USE and Service Sears, Roebuck and CoSafety Precautions Table of Contents Product Specifications Customer ResponsibilitiesAdditional Tools Needed When Sweat Soldering Materials and Basic Tools NeededMaterials Needed Basic ToolsTypical Installation Pilot & Main BurnerInstallation Instructions Installation is Completed, seeRemoving the Old Water Heater Turn OFF the gas supply to the water heaterFacts to Consider About the Location Insulation Blankets ALL AIR from Inside Buildings See on page 10 and belowWater Piping Hotter Water can ScaldValve and Pipe Insulation Temperature-Pressure Relief Valve Venting Filling the Water HeaterLocal gas supplier for further information Gas Piping GAS Piping with Flexible Connector Sediment TrapsOperating Instructions Temperature Regulation SettingsService and Adjustment Tank Sediment CleaningVent System Inspection Burner InspectionReplacing the Pilot Assembly Removing the Burner Door AssemblyUltra Low NOx Natural Gas Burner External Inspection & Cleaning of the Flame Arrestor Cleaning the Pilot AssemblyCleaning the Combustion Chamber and Flame Arrestor Replacing the ThermocoupleTesting the Igniter System Replacing the Burner Door AssemblyPiezoelectric Igniter System Housekeeping Removing and Replacing the Gas Control Valve/ThermostatAnode Rod Inspection Temperature-Pressure Relief Valve Operation Drain Valve Washer ReplacementService DrainingTroubleshooting Guide Start Up ConditionsOperational Conditions CondensationRecovery Burner will not IgniteSmelly Water Pilot will not LightDrip from Relief Valve Thermostat Fails toShut OFF Combustion OdorsPilot Light Troubleshooting Chart Section a Pilot light will not lightParts Order List 153.330960 Gallon 153.330970MY-HOME

153.33097, 153.33096 specifications

Kenmore has long been a trusted name in home appliances, and their washer models 153.33096 and 153.33097 are no exception. These machines stand out for their modern features, advanced technology, and user-friendly characteristics that cater to the needs of today’s households.

One of the main features of both models is their efficient cleaning performance. The machines are equipped with a powerful wash system that ensures thorough dirt and stain removal, even from heavily soiled fabrics. The dual-action agitator in each model enhances the washing process by allowing optimal movement of laundry, resulting in cleaner clothes in less time.

In terms of capacity, the Kenmore 153.33096 and 153.33097 offer a generous wash drum size, accommodating large loads. This is particularly convenient for families or individuals who do laundry less frequently. The higher capacity not only saves time between cycles but also reduces water and energy consumption, making these washers environmentally friendly options.

The models feature various wash cycles and temperature settings to suit different fabric types and soiling levels. Users can select from options like delicate, heavy-duty, and quick wash cycles, providing flexibility for various laundry needs. This versatility is further enhanced by the inclusion of a digital display and intuitive controls, making it easy to customize each wash.

Another key characteristic of the 153.33096 and 153.33097 is the incorporation of advanced technology. The machines utilize a smart sensor system that detects load sizes and automatically adjusts water levels accordingly. This feature not only conserves water but also ensures optimal cleaning performance for every load.

Noise reduction technology is also a significant advantage of these Kenmore models. Using advanced sound-dampening materials, they operate quietly, making them a desirable choice for any household, especially in open-plan living spaces.

In summary, the Kenmore 153.33096 and 153.33097 washers are exemplary products that combine performance, efficiency, and user-friendly design. With their robust features, advanced technologies, and thoughtful characteristics, they deliver an exceptional laundry experience that meets the demands of modern life. Whether you're dealing with everyday laundry or specialized items, these Kenmore models offer tailored solutions to ensure outstanding cleanliness and convenience.