Minimum clearances between the water heater and combustible construction are 0 inch at the sides and rear, 4 inches (102 mm) at the front, and 6 inches (153 mm) from the vent pipe, see Figure 8. Clearance from the top of the jacket is 8 inches (203

mm)on most models. Note that a lesser dimension may be allowed on some models, refer to the label attached adjacent to the gas control valve on the water heater.

FIGURE 8.

A gas water heater cannot operate properly without the correct amount of air for combustion, see Figure 9. Do not install in a confined area such as a closet, unless you provide air as shown in the Locating The New Water Heater section. Never obstruct the flow of ventilation air. If you have any doubts or questions at all, call your gas supplier. Failure to provide the proper amount of combustion air can result in a fire or explosion and cause death, serious bodily injury, or property damage.

FIGURE 9.

If this water heater will be used in beauty shops, barber shops, cleaning establishments, or self-service laundries with dry cleaning equipment, it is imperative that the water heater or water heaters be installed so that combustion and ventilation air be taken directly from outdoors (direct vent).

Propellants of aerosol sprays and volatile compounds, (cleaners, chlorine based chemicals, refrigerants, etc.) in addition to being highly flammable in many cases, will also change to corrosive hydrochloric acid when exposed to the combustion products of the water heater. The results can be hazardous, and also cause product failure.

Insulation Blankets

Insulation blankets available to the general public for external use on gas water heaters are not necessary with Kenmore products. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters. Your Kenmore water heater meets or exceeds the National Appliance Energy Conservation Act standards with respect to insulation and standby loss requirements, making an insulation blanket unnecessary.

WARNING

Should you choose to apply an insulation blanket to this heater, you should follow these instructions (See Figure 1 for identification of components mentioned below). Failure to follow these instructions can restrict the air flow required for proper combustion, potentially resulting in fire, asphyxiation, serious personal injury or death.

Do not apply insulation to the top of the water heater, as this will interfere with safe operation of the draft hood.

Do not cover the outer door, thermostat or temperature & pressure relief valve.

Do not allow insulation to come within 2” (50.8 mm) of the floor to prevent blockage of combustion air flow to the burner.

Do not cover the instruction manual. Keep it on the side of the water heater or nearby for future reference.

10

Image 10
Contents GAS Water Heater Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.ASafe INSTALLATION, USE and Service Sears, Roebuck and CoSafety Precautions Table of Contents Product Specifications Customer ResponsibilitiesMaterials Needed Additional Tools Needed When Sweat SolderingMaterials and Basic Tools Needed Basic ToolsTypical Installation Pilot & Main BurnerRemoving the Old Water Heater Installation InstructionsInstallation is Completed, see Turn OFF the gas supply to the water heaterFacts to Consider About the Location Insulation Blankets ALL AIR from Inside Buildings See on page 10 and belowWater Piping Hotter Water can ScaldValve and Pipe Insulation Temperature-Pressure Relief Valve Venting Filling the Water HeaterLocal gas supplier for further information Gas Piping GAS Piping with Flexible Connector Sediment TrapsOperating Instructions Temperature Regulation SettingsVent System Inspection Service and AdjustmentTank Sediment Cleaning Burner InspectionReplacing the Pilot Assembly Removing the Burner Door AssemblyUltra Low NOx Natural Gas Burner Cleaning the Combustion Chamber and Flame Arrestor External Inspection & Cleaning of the Flame ArrestorCleaning the Pilot Assembly Replacing the ThermocoupleTesting the Igniter System Replacing the Burner Door AssemblyPiezoelectric Igniter System Housekeeping Removing and Replacing the Gas Control Valve/ThermostatAnode Rod Inspection Service Temperature-Pressure Relief Valve OperationDrain Valve Washer Replacement DrainingTroubleshooting Guide Start Up ConditionsOperational Conditions CondensationSmelly Water RecoveryBurner will not Ignite Pilot will not LightShut OFF Drip from Relief ValveThermostat Fails to Combustion OdorsPilot Light Troubleshooting Chart Section a Pilot light will not lightParts Order List 153.330960 Gallon 153.330970MY-HOME

153.33097, 153.33096 specifications

Kenmore has long been a trusted name in home appliances, and their washer models 153.33096 and 153.33097 are no exception. These machines stand out for their modern features, advanced technology, and user-friendly characteristics that cater to the needs of today’s households.

One of the main features of both models is their efficient cleaning performance. The machines are equipped with a powerful wash system that ensures thorough dirt and stain removal, even from heavily soiled fabrics. The dual-action agitator in each model enhances the washing process by allowing optimal movement of laundry, resulting in cleaner clothes in less time.

In terms of capacity, the Kenmore 153.33096 and 153.33097 offer a generous wash drum size, accommodating large loads. This is particularly convenient for families or individuals who do laundry less frequently. The higher capacity not only saves time between cycles but also reduces water and energy consumption, making these washers environmentally friendly options.

The models feature various wash cycles and temperature settings to suit different fabric types and soiling levels. Users can select from options like delicate, heavy-duty, and quick wash cycles, providing flexibility for various laundry needs. This versatility is further enhanced by the inclusion of a digital display and intuitive controls, making it easy to customize each wash.

Another key characteristic of the 153.33096 and 153.33097 is the incorporation of advanced technology. The machines utilize a smart sensor system that detects load sizes and automatically adjusts water levels accordingly. This feature not only conserves water but also ensures optimal cleaning performance for every load.

Noise reduction technology is also a significant advantage of these Kenmore models. Using advanced sound-dampening materials, they operate quietly, making them a desirable choice for any household, especially in open-plan living spaces.

In summary, the Kenmore 153.33096 and 153.33097 washers are exemplary products that combine performance, efficiency, and user-friendly design. With their robust features, advanced technologies, and thoughtful characteristics, they deliver an exceptional laundry experience that meets the demands of modern life. Whether you're dealing with everyday laundry or specialized items, these Kenmore models offer tailored solutions to ensure outstanding cleanliness and convenience.