Sediment Traps

Water heaters covered in this manual have been tested and approved for installation at elevations up to 2,000 feet (610

m)above sea level. For installation above 2,000 feet (610 m), the water heater’s Btu input should be reduced at the rate of 4 percent for each 1,000 feet (305 m) above sea level which requires replacement of the burner orifice in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54. Contact your local gas supplier for further information.

Failure to replace the standard orifice with the proper high altitude orifice when installed at elevations above 2,000 feet (610 m) could result in improper and inefficient operation of the appliance, producing carbon monoxide gas in excess of the safe limits. This could result in serious injury or death. Contact your local gas supplier for any specific changes that may be required in your area.

Contaminants in the gas lines may cause improper operation of the gas control valve that may result in fire or explosion. Before attaching the gas line be sure that all gas pipe is clean on the inside. To trap any dirt or foreign material in the gas supply line, a drip leg (sometimes called a sediment trap) must be incorporated in the piping. The drip leg must be readily accessible. Install in accordance with the Gas Piping section. Refer to the current edition of the National Fuel Gas Code, ANSI Z223.1/NFPA 54.

A sediment trap shall be installed as close to the inlet of the water heater as practical at the time of water heater installation. The sediment trap shall be either a tee fitting with a capped nipple in the bottom outlet or other device recognized as an effective sediment trap. If a tee fitting is used, it shall be installed in conformance with one of the methods of installation, shown in Figures 19 and 20.

Use pipe joint compound or Teflon tape marked as being resistant to the action of petroleum (Propane [L.P.]) gases.

The appliance and its gas connection must be leak tested before placing the appliance in operation.

The appliance and its individual shutoff valve shall be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 pound per square inch (3.5 kPa). It shall be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 pound per square inch (3.5 kPa).

Connecting the gas piping to the gas control valve of the water heater can be accomplished by either of the two methods shown in Figures 19 and 20.

TEFLON® is a registered trademark of E.I. Du Pont De Nemours and Company.

GROUND JOINT

UNION (OPTIONAL)

GAS CONTROL VALVE

 

 

 

 

 

 

3” MIN.

 

 

DRIP LEG

(76.2 mm)

 

 

(SEDIMENT TRAP)

 

 

 

 

 

 

FIGURE 19. GAS PIPING WITH FLEXIBLE CONNECTOR.

GROUND JOINT

UNION (OPTIONAL)

 

BLACK PIPE

GAS CONTROL

 

 

VALVE

3” MIN.

DRIP LEG

 

(76.2 mm)

(SEDIMENT TRAP)

 

FIGURE 20. GAS PIPING WITH ALL

BLACK IRON PIPE TO GAS CONTROL.

17

Image 17
Contents Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A GAS Water HeaterSears, Roebuck and Co Safe INSTALLATION, USE and ServiceSafety Precautions Table of Contents Customer Responsibilities Product SpecificationsMaterials and Basic Tools Needed Additional Tools Needed When Sweat SolderingMaterials Needed Basic ToolsPilot & Main Burner Typical InstallationInstallation is Completed, see Installation InstructionsRemoving the Old Water Heater Turn OFF the gas supply to the water heaterFacts to Consider About the Location Insulation Blankets See on page 10 and below ALL AIR from Inside BuildingsHotter Water can Scald Water PipingValve and Pipe Insulation Temperature-Pressure Relief Valve Local gas supplier for further information Filling the Water HeaterVenting Gas Piping Sediment Traps GAS Piping with Flexible ConnectorOperating Instructions Settings Temperature RegulationTank Sediment Cleaning Service and AdjustmentVent System Inspection Burner InspectionUltra Low NOx Natural Gas Burner Removing the Burner Door AssemblyReplacing the Pilot Assembly Cleaning the Pilot Assembly External Inspection & Cleaning of the Flame ArrestorCleaning the Combustion Chamber and Flame Arrestor Replacing the ThermocouplePiezoelectric Igniter System Replacing the Burner Door AssemblyTesting the Igniter System Anode Rod Inspection Removing and Replacing the Gas Control Valve/ThermostatHousekeeping Drain Valve Washer Replacement Temperature-Pressure Relief Valve OperationService DrainingStart Up Conditions Troubleshooting GuideCondensation Operational ConditionsBurner will not Ignite RecoverySmelly Water Pilot will not LightThermostat Fails to Drip from Relief ValveShut OFF Combustion OdorsSection a Pilot light will not light Pilot Light Troubleshooting Chart153.330960 Gallon 153.330970 Parts Order ListMY-HOME

153.33097, 153.33096 specifications

Kenmore has long been a trusted name in home appliances, and their washer models 153.33096 and 153.33097 are no exception. These machines stand out for their modern features, advanced technology, and user-friendly characteristics that cater to the needs of today’s households.

One of the main features of both models is their efficient cleaning performance. The machines are equipped with a powerful wash system that ensures thorough dirt and stain removal, even from heavily soiled fabrics. The dual-action agitator in each model enhances the washing process by allowing optimal movement of laundry, resulting in cleaner clothes in less time.

In terms of capacity, the Kenmore 153.33096 and 153.33097 offer a generous wash drum size, accommodating large loads. This is particularly convenient for families or individuals who do laundry less frequently. The higher capacity not only saves time between cycles but also reduces water and energy consumption, making these washers environmentally friendly options.

The models feature various wash cycles and temperature settings to suit different fabric types and soiling levels. Users can select from options like delicate, heavy-duty, and quick wash cycles, providing flexibility for various laundry needs. This versatility is further enhanced by the inclusion of a digital display and intuitive controls, making it easy to customize each wash.

Another key characteristic of the 153.33096 and 153.33097 is the incorporation of advanced technology. The machines utilize a smart sensor system that detects load sizes and automatically adjusts water levels accordingly. This feature not only conserves water but also ensures optimal cleaning performance for every load.

Noise reduction technology is also a significant advantage of these Kenmore models. Using advanced sound-dampening materials, they operate quietly, making them a desirable choice for any household, especially in open-plan living spaces.

In summary, the Kenmore 153.33096 and 153.33097 washers are exemplary products that combine performance, efficiency, and user-friendly design. With their robust features, advanced technologies, and thoughtful characteristics, they deliver an exceptional laundry experience that meets the demands of modern life. Whether you're dealing with everyday laundry or specialized items, these Kenmore models offer tailored solutions to ensure outstanding cleanliness and convenience.