Fit T & P valve insulation over valve. Make sure that the insulation does not interfere with the lever of the T & P valve.

Secure all insulation using tape.

Temperature-Pressure Relief Valve

HOT WATER

COLD WATER

OUTLET

INLET

SHUTOFF

VALVE

HOT COLD

DRAFT HOOD

TEMPERATURE - PRESSURE

RELIEF VALVE

(OPTIONAL TOP T&P RELIEF

VALVE NOT SHOWN)

DISCHARGE PIPE (Do not cap or plug)

DRAIN VALVE

FLOOR DRAIN

This heater is provided with a properly certified combination temperature - pressure relief valve by the manufacturer.

The valve is certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment as meeting the requirements for Relief Valves for Hot Water Supply Systems, ANSI Z21.22 and the code requirements of ASME.

If replaced, the valve must meet the requirements of local codes, but not less than a combination temperature and pressure relief valve certified as indicated in the above paragraph.

The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater (150 psi = 1,035kPa) and a discharge capacity not less than the water heater input rate as shown on the model rating plate.

For safe operation of the water heater, the relief valve must not be removed from its designated opening nor plugged.

The temperature-pressure relief valve must be installed directly into the fitting of the water heater designed for the relief valve. Position the valve downward and provide tubing so that any discharge will exit only within 6 inches (153 mm) above, or at any distance below the structural floor, see Figure 16. Be certain that no contact is made with any live electrical part. The discharge opening must not be blocked or reduced in size under any circumstances. Excessive length, over 30 feet (9.14 m), or use of more than four elbows can cause restriction and reduce the discharge capacity of the valve.

No valve or other obstruction is to be placed between the relief valve and the tank. Do not connect tubing directly to discharge drain unless a 6 inch air gap is provided. To prevent bodily injury, hazard to life, or property damage, the relief valve must be allowed to discharge water in quantities should circumstances demand. If the discharge pipe is not connected to a drain or other suitable means, the water flow may cause property damage.

FIGURE 16.

The Discharge Pipe:

Shall not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or other restrictions.

Shall not be plugged or blocked.

Shall be of material listed for hot water distribution.

Shall be installed so as to allow complete drainage of both the temperature-pressure relief valve, and the discharge pipe.

Shall terminate at an adequate drain.

Shall not have any valve between the relief valve and tank.

14

Image 14
Contents GAS Water Heater Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.ASafe INSTALLATION, USE and Service Sears, Roebuck and CoSafety Precautions Table of Contents Product Specifications Customer ResponsibilitiesMaterials Needed Additional Tools Needed When Sweat SolderingMaterials and Basic Tools Needed Basic ToolsTypical Installation Pilot & Main BurnerRemoving the Old Water Heater Installation InstructionsInstallation is Completed, see Turn OFF the gas supply to the water heaterFacts to Consider About the Location Insulation Blankets ALL AIR from Inside Buildings See on page 10 and belowWater Piping Hotter Water can ScaldValve and Pipe Insulation Temperature-Pressure Relief Valve Local gas supplier for further information Filling the Water HeaterVenting Gas Piping GAS Piping with Flexible Connector Sediment TrapsOperating Instructions Temperature Regulation SettingsVent System Inspection Service and AdjustmentTank Sediment Cleaning Burner InspectionUltra Low NOx Natural Gas Burner Removing the Burner Door AssemblyReplacing the Pilot Assembly Cleaning the Combustion Chamber and Flame Arrestor External Inspection & Cleaning of the Flame ArrestorCleaning the Pilot Assembly Replacing the ThermocouplePiezoelectric Igniter System Replacing the Burner Door AssemblyTesting the Igniter System Anode Rod Inspection Removing and Replacing the Gas Control Valve/ThermostatHousekeeping Service Temperature-Pressure Relief Valve OperationDrain Valve Washer Replacement DrainingTroubleshooting Guide Start Up ConditionsOperational Conditions CondensationSmelly Water RecoveryBurner will not Ignite Pilot will not LightShut OFF Drip from Relief ValveThermostat Fails to Combustion OdorsPilot Light Troubleshooting Chart Section a Pilot light will not lightParts Order List 153.330960 Gallon 153.330970MY-HOME

153.33097, 153.33096 specifications

Kenmore has long been a trusted name in home appliances, and their washer models 153.33096 and 153.33097 are no exception. These machines stand out for their modern features, advanced technology, and user-friendly characteristics that cater to the needs of today’s households.

One of the main features of both models is their efficient cleaning performance. The machines are equipped with a powerful wash system that ensures thorough dirt and stain removal, even from heavily soiled fabrics. The dual-action agitator in each model enhances the washing process by allowing optimal movement of laundry, resulting in cleaner clothes in less time.

In terms of capacity, the Kenmore 153.33096 and 153.33097 offer a generous wash drum size, accommodating large loads. This is particularly convenient for families or individuals who do laundry less frequently. The higher capacity not only saves time between cycles but also reduces water and energy consumption, making these washers environmentally friendly options.

The models feature various wash cycles and temperature settings to suit different fabric types and soiling levels. Users can select from options like delicate, heavy-duty, and quick wash cycles, providing flexibility for various laundry needs. This versatility is further enhanced by the inclusion of a digital display and intuitive controls, making it easy to customize each wash.

Another key characteristic of the 153.33096 and 153.33097 is the incorporation of advanced technology. The machines utilize a smart sensor system that detects load sizes and automatically adjusts water levels accordingly. This feature not only conserves water but also ensures optimal cleaning performance for every load.

Noise reduction technology is also a significant advantage of these Kenmore models. Using advanced sound-dampening materials, they operate quietly, making them a desirable choice for any household, especially in open-plan living spaces.

In summary, the Kenmore 153.33096 and 153.33097 washers are exemplary products that combine performance, efficiency, and user-friendly design. With their robust features, advanced technologies, and thoughtful characteristics, they deliver an exceptional laundry experience that meets the demands of modern life. Whether you're dealing with everyday laundry or specialized items, these Kenmore models offer tailored solutions to ensure outstanding cleanliness and convenience.