Desa CGD3924NR installation manual Operating Heater, Control Knob and Ignitor Button Location

Page 20

20

OPERATING HEATER

Continued

4. Press in and turn control knob clockwise to the OFF position.

 

Flame

Control Knob

 

 

 

 

Adjustment

 

 

 

Knob

 

 

REMOTE

 

IH

 

 

 

O

OFF

 

 

 

 

F

ON

 

N

F

 

O

P

 

 

LO

LI

 

 

TO

Ignitor Button

Selector Switch in OFF Position

Figure 19 - Control Knob and Ignitor Button Location

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step.

6. Press in and turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see above).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

7.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure on page 21.

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 through 8.

Ignitor Electrode

Pilot Burner

Figure 20 - Pilot

9. Slightly push in and turn control knob counterclockwise to the ON position.

10.Wait one minute and switch remote selector switch to the ON position to light burners.

11.Set flame adjustment knob to any level between HI and LO.

CAUTION

Do not try to adjust heating levels by using the manual shutoff valve.

WARNING

Make sure the remote selector switch is in the OFF position when you are away from home for long periods of time. Heater will come on automatically with remote selector switch in the ON position.

103343

Image 20
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Information Local Codes Unpacking Product Features Safety PilotOperation Piezo Ignition SystemProviding Adequate Ventilation AIR forVentilation Determining if You Have a Confined or Unconfined Space AIR for Combustion and VentilationDetermining AIR Flow for Heater Location Ventilation AIR Tion and ventilation air by one of the methods describedVentilation Air From Inside Building Ventilation Air From OutdoorsInstalling Check GAS TypeMinimum Wall and Ceiling Clearances see Figure Minimum Fireplace ClearanceLOG Sizing Requirements Minimum Non Combustible Material Clearances Installing Minimum Non Combustible Material Clearances Log SetMinimum Mantel Clearances When Using Hood Installing Heater Base Assembly Installation Items NeededAttaching Flexible Gas Hose to Heater Connecting to GAS Supply Checking GAS Connections Gas ConnectionInstalling Test Pressures Equal To or Less Than 1/2 PsigInstalling Logs Installing Back Log #1Operating HeaterOperating Heater Control Knob and Ignitor Button LocationOperating Inspecting Burners Has been selectedCleaning MaintenanceTrouble Shooting ODS/PILOT and BurnerMaintenance, TROUBLE- ShootingCleaning and Mainte TroubleGas leak. See Warning Wiring Diagram Technical ServiceService Hints Parts Central Parts Under WarrantyParts Not Under Warranty Accessories Valve GA5010Hood GA6050 Hood GA6052Illustrated Parts Breakdown CGD3924NR Parts List KEY Part Number Description QTYWarranty Information Keep this Warranty