Desa CGD3924NR Cleaning, Maintenance, Trouble Shooting, ODS/PILOT and Burner, Logs

Page 23

CLEANING

WARNING

AND

Turn off heater and let cool before cleaning.

MAINTENANCE

 

 

CAUTION

You must keep control areas, burner, and circulating air passage- ways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.

ODS/PILOT AND BURNER

• Use a vacuum cleaner or small, soft bristled brush to clean.

LOGS

If you remove logs for cleaning, refer to Installing Logs, page 18, to properly replace logs.

Replace log(s) if broken or chipped (dime-sized or larger).

TROUBLE-

 

 

WARNING

 

 

 

 

 

SHOOTING

 

 

 

 

 

 

 

Turn off heater and let cool before servicing. Only a qualified

 

 

Note: All troubleshoot-

service person should service and repair heater.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ing items are listed in

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

 

 

order of operation.

 

 

 

 

 

 

 

 

Never use a wire, needle, or similar object to clean ODS/pilot.

 

 

 

This can damage ODS/pilot unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OBSERVED

POSSIBLE

 

 

 

 

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

 

 

 

 

 

When ignitor button

1.

Ignitor electrode not con-

1.

Reconnect ignitor cable

 

is pressed, there is

 

nected to ignitor cable

 

 

 

 

 

 

no spark at ODS/

2.

Ignitor cable pinched or

2.

Free ignitor cable if

 

 

 

pilot

 

wet

 

pinched by any metal

 

 

 

 

 

 

 

or tubing. Keep ignitor

 

 

 

 

 

 

 

cable dry

 

 

 

 

3.

Piezo ignitor nut is loose

3.

Tighten nut holding

 

 

 

 

 

 

 

piezo ignitor to base

 

 

 

 

 

 

 

panel of log set. Nut is

 

 

 

 

 

 

 

located behind base

 

 

 

 

 

 

 

panel.

 

 

 

 

4.

Broken ignitor cable

4.

Replace ignitor cable

 

 

 

 

5.

Bad piezo ignitor

5.

Replace piezo ignitor

 

 

 

 

6.

Ignitor electrode broken

6.

Replace piezo ignitor

 

 

 

 

7.

Ignitor electrode posi-

7.

Replace piezo ignitor

 

 

 

 

 

tioned wrong

 

 

 

 

 

 

 

 

 

 

Continued

 

 

 

 

 

 

 

 

 

23

 

 

 

 

 

 

 

103343

Image 23
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Information Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Pilot OperationProviding Adequate Ventilation AIR forVentilation Determining if You Have a Confined or Unconfined Space AIR for Combustion and VentilationDetermining AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRTion and ventilation air by one of the methods described Ventilation Air From Inside BuildingCheck GAS Type InstallingMinimum Wall and Ceiling Clearances see Figure Minimum Fireplace ClearanceLOG Sizing Requirements Minimum Non Combustible Material Clearances Log Set Installing Minimum Non Combustible Material ClearancesMinimum Mantel Clearances When Using Hood Installation Items Needed Installing Heater Base AssemblyAttaching Flexible Gas Hose to Heater Connecting to GAS Supply Gas Connection Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig InstallingInstalling Back Log #1 Installing LogsHeater OperatingControl Knob and Ignitor Button Location Operating HeaterOperating Has been selected Inspecting BurnersODS/PILOT and Burner CleaningMaintenance Trouble ShootingTROUBLE- Shooting Maintenance,Trouble Cleaning and MainteGas leak. See Warning Wiring Diagram Technical ServiceService Hints Parts Central Parts Under WarrantyParts Not Under Warranty Hood GA6052 AccessoriesValve GA5010 Hood GA6050Illustrated Parts Breakdown CGD3924NR KEY Part Number Description QTY Parts ListKeep this Warranty Warranty Information