Desa Tech CGG3324PT, CGG2618P Inspecting Burners, Variable Control Operation, Pilot Flame Pattern

Page 17

OWNER’S MANUAL

OPERATING

HEATER

Continued

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation, page 16. If you don’t smell gas, go to the next step.

5.Press in control knob and turn counter-

clockwise C-clockwiseto the PILOT posi- tion. Keep control knob pressed in for five (5) seconds (see Figure 23, page 16).

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

6.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing igni- tor button until pilot lights.

Note: If pilot does not light, contact a qualified service person or gas sup- plier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

8.Push in and turn control knob coun-

terclockwise C-clockwiseto the HIGH position. Both burners should light. Set control knob to desired setting.

Ignitor Electrode

Thermocouple

Pilot Burner

Figure 24 - Pilot

VARIABLE CONTROL

OPERATION

The variable control valve can be set to any heat setting and flame height desired between high and low by simply turning the control knob until that setting is at- tained. Even the lowest setting provides realistic flames and glowing embers from two burners. Selecting higher settings pro- duces greater heat output. This results in increased heating comfort.

WARNING: Do not operate heater between pilot and high.

CAUTION: Do not try to adjust heating levels by using the manual shutoff valve.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Press in and turn control knob clock-

wise Clockwise to the HIGH position.

2.Turn the control knob clockwise Clockwise to the PILOT position.

3.Press in control knob and turn clock-

wise Clockwise to the OFF Position.

Shutting Off Burners Only (pilot stays lit)

1.Turn the control knob clockwise Clockwise to the HIGH position.

2.Press in and turn control knob clock-

wise Clockwise to the pilot position.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Light- ing Instructions, page 16.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, column 1.

INSPECTING

BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT FLAME PATTERN

Figure 25 shows a correct pilot flame pattern. Figure 26 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touch- ing the thermocouple. This will cause the thermocouple to cool. When the thermo- couple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 26

turn heater off (see To Turn Off Gas to Appliance, page 16 [Thermostat-Con- trolled Models] or page 17 or [Variable Manually-Controlled Models])

see Troubleshooting, pages 19 through 21

Thermocouple

Pilot Burner

Figure 25 - Correct Pilot Flame Pattern

Thermocouple

Pilot Burner

Figure 26 - Incorrect Pilot Flame Pattern

Continued

103425

17

Image 17
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualUnvented VENT-FREE GAS LOG Heater Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsInstallation Clearances InstallationCheck GAS Type Minimum Fireplace Clearance to Combustible MaterialsMinimum Noncombustible Material Clearances If Using MantelMantel Clearances Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationAttaching Flexible Gas Hose to Heater Gas Regulator Installation Items NeededExternal Regulator With Vent Pointing Down Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Installing Rear Log Installing LogsLighting Instructions For Your Safety Read Before LightingOperating Heater Thermostat Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Pilot Flame Pattern Inspecting BurnersVariable Control Operation Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceFront Burner Flame Pattern LogsObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at For Masonry and FACTORY-BUILT Metal Fireplace Optional Positioning of Thermostat Sensing BulbService Hints SpecificationsTechnical Service Replacement PartsVariable Manually Controlled Models Illustrated Parts BreakdownVariable MANUALLY- Controlled Models Parts ListThermostat Controlled Models KEY Part Number Description QTY CGG3324PTParts Centrals Accessories103425 Keep this Warranty Warranty Information

CGG2618P, CGG3630P, CGG3324PT specifications

Desa Tech is a well-known name in the realm of innovative and efficient heating solutions, and its CGG2618P, CGG3630P, and CGG3324PT models exemplify the brand's commitment to excellence in design and functionality. Each of these products is tailored to meet specific heating needs while incorporating advanced technologies for improved efficiency and user experience.

The CGG2618P is a compact yet powerful gas heater designed for smaller spaces. With a maximum output of 26,000 BTUs, it can easily warm up a room quickly and efficiently. One of its standout features is the built-in thermostat, which allows users to set their desired temperature with precision, ensuring comfort without wasteful energy use. The heater also includes an electronic ignition system, offering hassle-free startup. Its sleek design and lightweight construction make it easy to move wherever heating is needed.

On the other hand, the CGG3630P boasts a larger capacity with a maximum output of 36,000 BTUs, making it ideal for larger rooms or even garages and workshops. This model features dual heat settings, allowing users to customize their heating experience based on the size of the space and the external temperature. The innovative flame sensing technology ensures that the unit operates safely by automatically shutting off the gas supply when the flame is not detected. Additionally, it is designed with a durable casing that can withstand the wear and tear of everyday use, ensuring longevity and reliability.

The CGG3324PT combines elements from both models to cater to versatile heating needs. With an output of 33,000 BTUs, it is suitable for medium to larger-sized spaces. This model is unique for its portability, equipped with wheels that make it easy to transport from room to room. It also features a piezo ignition system, which requires no external power source, enhancing its usability in power outages or remote locations. Furthermore, the CGG3324PT is designed with safety in mind, featuring an automatic shut-off function that activates in the event of overheating.

All three models from Desa Tech share a commitment to energy efficiency. Utilizing advanced combustion technologies, they minimize fuel consumption while maximizing heat output. This means not only lower energy bills but also a smaller carbon footprint. Additionally, their sleek designs add a touch of modernity to any space while providing efficient heating solutions.

In summary, Desa Tech's CGG2618P, CGG3630P, and CGG3324PT models offer a range of features and technologies that cater to diverse heating requirements. Whether it's for a small room, a workshop, or consistent indoor comfort, these models provide effective and efficient solutions while prioritizing safety and user convenience.