Desa Tech CGG3630P, CGG2618P, CGG3324PT Parts List, Variable MANUALLY- Controlled Models

Page 25

OWNER’S MANUAL

PARTS LIST

VARIABLE MANUALLY- CONTROLLED MODELS

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 23 of this manual.

CGG2618P

CGG3324P

CGG3630P

 

KEY

PART NUMBER FOR

 

 

 

NO.

CGG2618P

CGG3324P

CGG3630P

DESCRIPTION

QTY.

 

 

 

 

 

 

 

 

1

103681-04

103682-04

103683-04

Rear Log (#1)

1

 

2

103681-02

103682-02

103683-02

Bottom Mid Log (#2)

1

 

3

103681-01

103682-01

103683-01

Front Log (#3)

1

 

4

103681-03

103682-03

103683-03

Top Log (#4)

1

 

5

098249-01

098249-01

098249-01

Nut

4

 

6

101006-01

101006-01

101006-01

Pilot Bracket

1

 

7

101330-01

101330-05

101330-06

Front Burner Assembly

1

 

7-1

101008-01

101008-01

101008-01

Crossover Burner Gasket

1

 

7-2

101007-01

101007-01

101007-01

Crossover Burner

1

 

8

100999-01

100999-02

100999-03

Rear Burner Assembly

1

 

9

101331-10

101331-08

101331-09

Base Assembly (Includes Decals)

1

 

10

098271-07

098271-06

098271-06

Ignitor Cable

1

 

11

102445-01

102445-01

102445-01

Piezo Ignitor

1

 

12

098867-10

098867-10

098867-10

Gas Regulator

1

 

13

M11084-38

M11084-38

M11084-38

Screw

2

 

14

101011-01

101011-02

101011-03

Inlet Tube

1

 

15

098354-01

098354-01

098354-01

Control Knob

1

 

16

098462-03

098462-03

098462-03

Control Rod

1

 

17

098325-01

098325-01

098325-01

Roll Pin

1

 

18

098508-01

098508-01

098508-01

Valve Retainer Nut

1

 

19

102568-02

102568-02

102568-02

Gas Valve

1

 

20

101005-01

101005-01

101005-01

Valve Bracket

1

 

21

M11084-26

M11084-26

M11084-26

Screw

4

 

22

101004-10

101004-01

101004-02

Rear Burner Injector

1

 

23

101004-10

101004-02

101004-06

Front Burner Injector

 

 

24

102258-01

102258-01

102258-01

Burner Tube

1

 

25

099387-08

099387-08

099387-08

Pilot Tube

1

 

26

098276-01

098276-01

098276-01

1/8” Plug

1

 

27

099059-02

099059-02

099059-02

O.D.S. Pilot

1

 

27-1

098594-01

098594-01

098594-01

Ignitor Electrode

1

 

27-2

098593-01

098593-01

098593-01

Thermocouple

1

 

 

 

 

 

 

 

PARTS AVAILABLE — NOT SHOWN

100563-01

101054-01

100565-01

100639-01

101137-03

101416-28 GA6060

100563-01

101054-01

100565-01

100639-01

101137-03

101416-28 GA6060

100563-01

101054-01

100565-01

100639-01

101137-03

101416-28 GA6060

Warning Plate

Lighting Instructions Plate

Warning Plate Fastener

Caution Decal

Hardware Kit

Information Video

Lava Rock

1

1

1

1

1

1

1

103425

25

Image 25
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualUnvented VENT-FREE GAS LOG Heater Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsInstallation Clearances InstallationCheck GAS Type Minimum Fireplace Clearance to Combustible MaterialsMinimum Noncombustible Material Clearances If Using MantelMantel Clearances Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationAttaching Flexible Gas Hose to Heater Gas Regulator Installation Items NeededExternal Regulator With Vent Pointing Down Connecting to GAS SupplyPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Installing Rear Log Installing LogsOperating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Variable Control Operation Inspecting BurnersPilot Flame Pattern Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceFront Burner Flame Pattern LogsObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at For Masonry and FACTORY-BUILT Metal Fireplace Optional Positioning of Thermostat Sensing BulbService Hints SpecificationsTechnical Service Replacement PartsVariable Manually Controlled Models Illustrated Parts BreakdownVariable MANUALLY- Controlled Models Parts ListThermostat Controlled Models KEY Part Number Description QTY CGG3324PTParts Centrals Accessories103425 Keep this Warranty Warranty Information

CGG2618P, CGG3630P, CGG3324PT specifications

Desa Tech is a well-known name in the realm of innovative and efficient heating solutions, and its CGG2618P, CGG3630P, and CGG3324PT models exemplify the brand's commitment to excellence in design and functionality. Each of these products is tailored to meet specific heating needs while incorporating advanced technologies for improved efficiency and user experience.

The CGG2618P is a compact yet powerful gas heater designed for smaller spaces. With a maximum output of 26,000 BTUs, it can easily warm up a room quickly and efficiently. One of its standout features is the built-in thermostat, which allows users to set their desired temperature with precision, ensuring comfort without wasteful energy use. The heater also includes an electronic ignition system, offering hassle-free startup. Its sleek design and lightweight construction make it easy to move wherever heating is needed.

On the other hand, the CGG3630P boasts a larger capacity with a maximum output of 36,000 BTUs, making it ideal for larger rooms or even garages and workshops. This model features dual heat settings, allowing users to customize their heating experience based on the size of the space and the external temperature. The innovative flame sensing technology ensures that the unit operates safely by automatically shutting off the gas supply when the flame is not detected. Additionally, it is designed with a durable casing that can withstand the wear and tear of everyday use, ensuring longevity and reliability.

The CGG3324PT combines elements from both models to cater to versatile heating needs. With an output of 33,000 BTUs, it is suitable for medium to larger-sized spaces. This model is unique for its portability, equipped with wheels that make it easy to transport from room to room. It also features a piezo ignition system, which requires no external power source, enhancing its usability in power outages or remote locations. Furthermore, the CGG3324PT is designed with safety in mind, featuring an automatic shut-off function that activates in the event of overheating.

All three models from Desa Tech share a commitment to energy efficiency. Utilizing advanced combustion technologies, they minimize fuel consumption while maximizing heat output. This means not only lower energy bills but also a smaller carbon footprint. Additionally, their sleek designs add a touch of modernity to any space while providing efficient heating solutions.

In summary, Desa Tech's CGG2618P, CGG3630P, and CGG3324PT models offer a range of features and technologies that cater to diverse heating requirements. Whether it's for a small room, a workshop, or consistent indoor comfort, these models provide effective and efficient solutions while prioritizing safety and user convenience.