Desa Tech CGG3630P, CGG2618P, CGG3324PT To Turn OFF GAS To Appliance, Thermostat Control Operation

Page 16

UNVENTED (VENT-FREE) GAS LOG HEATER

OPERATING

HEATER

Continued

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise to the OFF position.

Shutting Off Burners Only (pilot stays lit)

Turn control knob clockwise to the PILOT position.

THERMOSTAT

CONTROL OPERATION

(Thermostat-Controlled

Models Only)

The thermostat control knob can be set to any comfort level between Hi and Lo. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

Note: Selecting the Hi setting with the control knob will cause the burners to remain fully on, without modulating down in most cases.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Light- ing Instructions, page 15.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, page 15.

Variable Manually-Controlled Models

FOR YOUR

SAFETY READ

BEFORE LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When light- ing the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been un- der water.

LIGHTING

INSTRUCTIONS

WARNING:

If fireplace has glass doors, never operate this heater with glass doors closed. If you oper- ate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the High heat setting but will find the heat output excessive. You can open the chim- ney damper (if you have one) fully or partially to release some of the heat.

WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information column 2.

2.Make sure manual shutoff valve is fully open.

3.Press in and turn control knob clock-

wise

Clockwise

to the OFF

position.

 

 

 

 

HIPILOT

 

OFF

 

LO

Ignitor Button

Control Knob

Figure 23 - Control Knob and Ignitor Button Location

16

103425

Image 16
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information Unvented VENT-FREE GAS LOG HeaterProduct Features Product IdentificationLocal Codes UnpackingAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation Installation ClearancesCheck GAS Type Minimum Fireplace Clearance to Combustible MaterialsIf Using Mantel Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Attaching Flexible Gas Hose to Heater Gas RegulatorConnecting to GAS Supply External Regulator With Vent Pointing DownPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Installing Logs Installing Rear LogOperating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Variable Control Operation Inspecting BurnersPilot Flame Pattern Cleaning and Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleFront Burner Flame Pattern LogsTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Optional Positioning of Thermostat Sensing Bulb For Masonry and FACTORY-BUILT Metal FireplaceSpecifications Service HintsTechnical Service Replacement PartsIllustrated Parts Breakdown Variable Manually Controlled ModelsParts List Variable MANUALLY- Controlled ModelsThermostat Controlled Models CGG3324PT KEY Part Number Description QTYAccessories Parts Centrals103425 Warranty Information Keep this Warranty

CGG2618P, CGG3630P, CGG3324PT specifications

Desa Tech is a well-known name in the realm of innovative and efficient heating solutions, and its CGG2618P, CGG3630P, and CGG3324PT models exemplify the brand's commitment to excellence in design and functionality. Each of these products is tailored to meet specific heating needs while incorporating advanced technologies for improved efficiency and user experience.

The CGG2618P is a compact yet powerful gas heater designed for smaller spaces. With a maximum output of 26,000 BTUs, it can easily warm up a room quickly and efficiently. One of its standout features is the built-in thermostat, which allows users to set their desired temperature with precision, ensuring comfort without wasteful energy use. The heater also includes an electronic ignition system, offering hassle-free startup. Its sleek design and lightweight construction make it easy to move wherever heating is needed.

On the other hand, the CGG3630P boasts a larger capacity with a maximum output of 36,000 BTUs, making it ideal for larger rooms or even garages and workshops. This model features dual heat settings, allowing users to customize their heating experience based on the size of the space and the external temperature. The innovative flame sensing technology ensures that the unit operates safely by automatically shutting off the gas supply when the flame is not detected. Additionally, it is designed with a durable casing that can withstand the wear and tear of everyday use, ensuring longevity and reliability.

The CGG3324PT combines elements from both models to cater to versatile heating needs. With an output of 33,000 BTUs, it is suitable for medium to larger-sized spaces. This model is unique for its portability, equipped with wheels that make it easy to transport from room to room. It also features a piezo ignition system, which requires no external power source, enhancing its usability in power outages or remote locations. Furthermore, the CGG3324PT is designed with safety in mind, featuring an automatic shut-off function that activates in the event of overheating.

All three models from Desa Tech share a commitment to energy efficiency. Utilizing advanced combustion technologies, they minimize fuel consumption while maximizing heat output. This means not only lower energy bills but also a smaller carbon footprint. Additionally, their sleek designs add a touch of modernity to any space while providing efficient heating solutions.

In summary, Desa Tech's CGG2618P, CGG3630P, and CGG3324PT models offer a range of features and technologies that cater to diverse heating requirements. Whether it's for a small room, a workshop, or consistent indoor comfort, these models provide effective and efficient solutions while prioritizing safety and user convenience.