Desa Tech CGG3630P, CGG2618P AIR for Combustion and Ventilation, Providing Adequate Ventilation

Page 4

UNVENTED (VENT-FREE) GAS LOG HEATER

AIR FOR COMBUSTION AND VENTILATION

WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ven- tilation air. Read the following in- structions to insure proper fresh air for this and other fuel-burning appliances in your home.

Today’s homes are built more energy efficient than ever. New materials, increased insula- tion, and new construction methods help re- duceheatlossinhomes.Homeownersweather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com- bustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad- equate fresh air for these appliances. This will insure proper venting of vented fuel- burning appliances.

PROVIDING ADEQUATE VENTILATION

The following are excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation.

All spaces in homes fall into one of the three following ventilation classifications:

1.Unusually Tight Construction

2.Unconfined Space

3.Confined Space

The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

The air that leaks around doors and win- dows may provide enough fresh air for com- bustion and ventilation. However, in build- ings of unusually tight construction, you must provide additional fresh air.

Unusually tight construction is de- fined as construction where:

a.walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm (6 x 10-11kg per pa-sec-m2) or less with openings gasketed or sealed and

b.weather stripping has been added on openable windows and doors and

c.caulking or sealants are applied to areas such as joints around window and door frames, be- tween sole plates and floors, be- tween wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.

If your home meets all of the three criteria above, you must provide ad- ditional fresh air. See Ventilation Air From Outdoors, page 6.

If your home does not meet all of the three criteria above, proceed to De- termining Fresh-Air Flow for Heater Location, page 5.

Confined and Unconfined Space

The National Fuel Gas Code (ANS Z223.1, 1992 Section 5.3) defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfining space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are in- stalled*, through openings not furnished with doors, are considered a part of the unconfined space.

This heater shall not be installed in a con- fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.

*Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.

4

103425

Image 4
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information Unvented VENT-FREE GAS LOG HeaterProduct Features Product IdentificationLocal Codes UnpackingAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation Installation ClearancesCheck GAS Type Minimum Fireplace Clearance to Combustible MaterialsIf Using Mantel Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Attaching Flexible Gas Hose to Heater Gas RegulatorConnecting to GAS Supply External Regulator With Vent Pointing DownPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Installing Logs Installing Rear LogOperating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Variable Control Operation Inspecting BurnersPilot Flame Pattern Cleaning and Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleFront Burner Flame Pattern LogsTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Optional Positioning of Thermostat Sensing Bulb For Masonry and FACTORY-BUILT Metal FireplaceSpecifications Service HintsTechnical Service Replacement PartsIllustrated Parts Breakdown Variable Manually Controlled ModelsParts List Variable MANUALLY- Controlled ModelsThermostat Controlled Models CGG3324PT KEY Part Number Description QTYAccessories Parts Centrals103425 Warranty Information Keep this Warranty

CGG2618P, CGG3630P, CGG3324PT specifications

Desa Tech is a well-known name in the realm of innovative and efficient heating solutions, and its CGG2618P, CGG3630P, and CGG3324PT models exemplify the brand's commitment to excellence in design and functionality. Each of these products is tailored to meet specific heating needs while incorporating advanced technologies for improved efficiency and user experience.

The CGG2618P is a compact yet powerful gas heater designed for smaller spaces. With a maximum output of 26,000 BTUs, it can easily warm up a room quickly and efficiently. One of its standout features is the built-in thermostat, which allows users to set their desired temperature with precision, ensuring comfort without wasteful energy use. The heater also includes an electronic ignition system, offering hassle-free startup. Its sleek design and lightweight construction make it easy to move wherever heating is needed.

On the other hand, the CGG3630P boasts a larger capacity with a maximum output of 36,000 BTUs, making it ideal for larger rooms or even garages and workshops. This model features dual heat settings, allowing users to customize their heating experience based on the size of the space and the external temperature. The innovative flame sensing technology ensures that the unit operates safely by automatically shutting off the gas supply when the flame is not detected. Additionally, it is designed with a durable casing that can withstand the wear and tear of everyday use, ensuring longevity and reliability.

The CGG3324PT combines elements from both models to cater to versatile heating needs. With an output of 33,000 BTUs, it is suitable for medium to larger-sized spaces. This model is unique for its portability, equipped with wheels that make it easy to transport from room to room. It also features a piezo ignition system, which requires no external power source, enhancing its usability in power outages or remote locations. Furthermore, the CGG3324PT is designed with safety in mind, featuring an automatic shut-off function that activates in the event of overheating.

All three models from Desa Tech share a commitment to energy efficiency. Utilizing advanced combustion technologies, they minimize fuel consumption while maximizing heat output. This means not only lower energy bills but also a smaller carbon footprint. Additionally, their sleek designs add a touch of modernity to any space while providing efficient heating solutions.

In summary, Desa Tech's CGG2618P, CGG3630P, and CGG3324PT models offer a range of features and technologies that cater to diverse heating requirements. Whether it's for a small room, a workshop, or consistent indoor comfort, these models provide effective and efficient solutions while prioritizing safety and user convenience.