Desa Tech CGG3324PT, CGG2618P Minimum Noncombustible Material Clearances, If Using Mantel

Page 8

UNVENTED (VENT-FREE) GAS LOG HEATER

INSTALLATION

Continued

NOTICE: Manual control heaters may be used as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, noncombustible material above fireplace opening is not needed. Go to Installing Damper Clamp Accessory for Vented

If Using Mantel

You must have noncombustible material(s) above the fireplace opening. Noncombus- tible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible mate- rial must extend at least 8 inches up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). Even

if noncombustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See Figure 5 and Figures 6 and 7, page 9, for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 10.

Operation, page 10.

Minimum Noncombustible Material Clearances

If Not Using Mantel

Note: If using a mantel, proceed to If Using Mantel. If not using a mantel, follow the information on this page.

You must have noncombustible material(s) above the fireplace opening. Noncombus- tible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible mate- rial must extend at least 8" up (for all mod- els). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). See Figure 5 for minimum clearances.

IMPORTANT: If you cannot meet these mini- mum clearances, you must operate heater with chimney flue damper open. Go to In- stalling Damper Clamp Accessory for Vented Operation, page 10.

Noncombustible

Requirements for

Material Distance (A)

Safe Installation

 

 

12" or more

Noncombustible material OK.

Between 8" and 12"

24" or 30" Models: Install fireplace hood accessory

 

(GA6050 or GA6052, see Accessories, page 28).

 

18" Model: Noncombustible material OK. No hood

 

accessory needed.

Less than 8"

Noncombustible material must be extended to at

 

least 8". See Between 8" and 12", above. If you

 

cannot extend material, you must operate heater

 

with flue damper open.

Heat Resistant

Material

(A)

Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace

8

103425

Image 8
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information Unvented VENT-FREE GAS LOG HeaterProduct Features Product IdentificationLocal Codes UnpackingAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation Installation ClearancesCheck GAS Type Minimum Fireplace Clearance to Combustible MaterialsIf Using Mantel Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Attaching Flexible Gas Hose to Heater Gas RegulatorConnecting to GAS Supply External Regulator With Vent Pointing DownChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Installing Logs Installing Rear LogLighting Instructions For Your Safety Read Before LightingOperating Heater Thermostat Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Pilot Flame Pattern Inspecting BurnersVariable Control Operation Cleaning and Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleFront Burner Flame Pattern LogsTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Optional Positioning of Thermostat Sensing Bulb For Masonry and FACTORY-BUILT Metal FireplaceSpecifications Service HintsTechnical Service Replacement PartsIllustrated Parts Breakdown Variable Manually Controlled ModelsParts List Variable MANUALLY- Controlled ModelsThermostat Controlled Models CGG3324PT KEY Part Number Description QTYAccessories Parts Centrals103425 Warranty Information Keep this Warranty

CGG2618P, CGG3630P, CGG3324PT specifications

Desa Tech is a well-known name in the realm of innovative and efficient heating solutions, and its CGG2618P, CGG3630P, and CGG3324PT models exemplify the brand's commitment to excellence in design and functionality. Each of these products is tailored to meet specific heating needs while incorporating advanced technologies for improved efficiency and user experience.

The CGG2618P is a compact yet powerful gas heater designed for smaller spaces. With a maximum output of 26,000 BTUs, it can easily warm up a room quickly and efficiently. One of its standout features is the built-in thermostat, which allows users to set their desired temperature with precision, ensuring comfort without wasteful energy use. The heater also includes an electronic ignition system, offering hassle-free startup. Its sleek design and lightweight construction make it easy to move wherever heating is needed.

On the other hand, the CGG3630P boasts a larger capacity with a maximum output of 36,000 BTUs, making it ideal for larger rooms or even garages and workshops. This model features dual heat settings, allowing users to customize their heating experience based on the size of the space and the external temperature. The innovative flame sensing technology ensures that the unit operates safely by automatically shutting off the gas supply when the flame is not detected. Additionally, it is designed with a durable casing that can withstand the wear and tear of everyday use, ensuring longevity and reliability.

The CGG3324PT combines elements from both models to cater to versatile heating needs. With an output of 33,000 BTUs, it is suitable for medium to larger-sized spaces. This model is unique for its portability, equipped with wheels that make it easy to transport from room to room. It also features a piezo ignition system, which requires no external power source, enhancing its usability in power outages or remote locations. Furthermore, the CGG3324PT is designed with safety in mind, featuring an automatic shut-off function that activates in the event of overheating.

All three models from Desa Tech share a commitment to energy efficiency. Utilizing advanced combustion technologies, they minimize fuel consumption while maximizing heat output. This means not only lower energy bills but also a smaller carbon footprint. Additionally, their sleek designs add a touch of modernity to any space while providing efficient heating solutions.

In summary, Desa Tech's CGG2618P, CGG3630P, and CGG3324PT models offer a range of features and technologies that cater to diverse heating requirements. Whether it's for a small room, a workshop, or consistent indoor comfort, these models provide effective and efficient solutions while prioritizing safety and user convenience.