Cleaning and

Maintenance

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep controlareas,burnerandcirculat- ing air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace and chimney inspected yearly by a qualified service per- son. Fireplace may need more frequent cleaning due to exces- sive lint from carpeting, bedding material, pet hair, etc.

Only limited cleaning will be required under normal use of this appliance. Dust front grate and top of receiver/valve. Do not use cleaning fluids to clean logs or any other part of the appliance.

If after a period of use the flames start to exhibit unusual shapes and behavior or burner fails to ignite smoothly, burner holes may require cleaning. If this happens, we recommend you contact your nearest authorized service technician to get the appliance serviced.

Keep area around log set clean and clear of de- bris.

Periodically inspect burner for foreign matter blocking air inlet and flame holes.

Once every year a qualified agency or certified chimney sweep should examine and clean venting system of fireplace.

Specifications

Models VTD-18N-PDG and VTD-18N-BTB

• Input Rating: 37,000/54,000 Btu/Hr

• Fuel: Natural Gas

• Ignition: Electronic

• Manifold Pressure: 3.5" W.C.

• Inlet Gas Pressure (in. of water): Max. - 10.5", Min. - 5.0*

• Shipping Weight: 32 lbs.

Models VTD-18P-PDG and VTD-18P-BTB

• Input Rating: 30,000/46,000 Btu/Hr

• Fuel: Propane/LP Gas

• Ignition: Electronic

• Manifold Pressure: 10" W.C.

• Inlet Gas Pressure (in. of water): Max.- 14", Min. - 11"*

• Shipping Weight: 32 lbs.

Models VTD-24N-PDG and VTD-24N-BTB

• Input Rating: 41,000/58,000 Btu/Hr

• Fuel: Natural Gas

• Ignition: Electronic

• Manifold Pressure: 3.5" W.C.

• Inlet Gas Pressure (in. of water): Max. - 10.5", Min. - 5.0*

• Shipping Weight: 34 lbs.

Models VTD-24P-PDG and VTD-24P-BTB

• Input Rating: 41,000/58,000 Btu/Hr

• Fuel: Propane/LP Gas

• Ignition: Electronic

• Manifold Pressure: 10" W.C.

• Inlet Gas Pressure (in. of water): Max.- 14", Min. - 11"*

• Shipping Weight: 34 lbs.

* For purpose of input adjustment

Wiring Diagram

AUTO

OFF

ON

Thermopile

14

www.desatech.com

111826-02J

Image 14
Contents What to do if YOU Smell GAS Table of Contents Safety Information Local Codes High traffic areas Windy or drafty areasProduct Identification Product FeaturesOptional Remote Control Accessories UnpackingVenting specifications for installation InstallationInstallation and Clearances Flue Opening SpecificationsConnecting to gas supply Installing Damper ClampInstalling Heater Assembly Installation Items NeededPropane/LP Gas InstallationNatural Gas Checking gas connections Test Pressures Equal To or Less Than Psig 3.5 kPaOperating Heater For your safety Read before lightingPressure Testing Heater Gas Connections Lighting Instructions Control KnobTo Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Hand-held Remote control OperationBurner Flame Pattern Inspecting BurnersPilot Flame Pattern Wiring Diagram Cleaning MaintenanceSpecifications Troubleshooting Observed Problem Possible Cause RemedyODS/pilot lights but flame goes See Cleaning and Mainte Gas leak. See Warning See Checking Gas ConnecReplacement Parts Service HintsTechnical Service AccessoriesIllustrated Parts Breakdown Models vTD-18n-Pdg, vtd-18p-Pdg, vtd-18N-BTB and vtd-18P-BTBParts List Illustrated Parts Breakdown Models vtd-24n-Pdg, vtd-24p-Pdg, vtd-24N-BTB and vtd-24P-BTBVenturi/Shutter Assembly Limited Warranty Vented GAS LOG Heaters Warranty InformationKeep this Warranty