INSTALLATION
Continued
CAUTION: Never connect propane/LP fireplace directly to the propane/LP supply. This heater requires an external regu- lator (not supplied). Install the external regulator between the heater and propane/LP supply.
WARNING: Never connect natural gas fireplace to private
Installation Items Needed
Before installing heater, make sure you have the items listed below.
•external regulator (for propane/LP units only, supplied by installer)
•piping (check local codes)
•sealant (resistant to propane/LP gas)
•equipment shutoff valve *
•test gauge connection *
•sediment trap
•tee joint
•pipe wrench
•approved flexible gas line with gas connector (if allowed by local codes) (provided)
*A CSA
For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11" and 14" of water. If you do not reduce incoming gas pres- sure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 6. Pointing the vent down protects it from freezing rain or sleet.
CAUTION:Useonlynew,black
Installation must include an equipment shutoff valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 7).
IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.
Propane/LP |
|
Supply Tank | External |
| Regulator |
| Vent |
| Pointing |
| Down |
Figure 6 - External Regulator With Vent
Pointing Down
To Gas
Control CSA
Equipment Shutoff Valve
With 1/8" NPT Tap*
| Natural Gas | |
| From Gas Meter | |
Approved | (5" W.C.** to 10.5" | |
W.C. Pressure) | ||
Flexible Gas | ||
Propane/LP Gas | ||
Hose (if allowed | ||
From External | ||
by local codes) | ||
Regulator | ||
| ||
| (11" W.C.** to | |
3" Minimum | 14" W.C. | |
Pressure) | ||
|
Cap Pipe Tee
Nipple Joint
Sediment Trap
Figure 7 - Gas Connection
*Purchase the optional CSA
Accessories, page 25.
** Minimum inlet pressure for purpose of input adjustment.
www.desatech.com111826-02J