Carrier Unit Weight 48EJ,EK,EW,EYD024, 48EJ,EK,EW,EYD028 48EJ,EK,EW,EYD030, 48EJ,EK,EW,EYD034

Page 9

UNIT

WEIGHT

A

 

 

B

 

C

lb

kg

in.

 

mm

in.

 

mm

in.

 

mm

 

 

 

 

48EJ,EK,EW,EYD024

4176

1894

 

 

 

72.4

 

1839

42.4

 

1072

48EJ,EWE024

4256

1930

 

 

 

73.3

 

1862

42.7

 

1085

48EJ,EK,EW,EYD028

 

 

 

 

 

 

 

 

 

 

 

48EJ,EK,EW,EYD030

4262

1933

87.68

 

2227

69.6

 

1768

44.0

 

1118

48EJ,EK,EW,EYD034

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48EJ,EWE028

 

 

 

 

 

 

 

 

 

 

 

48EJ,EWE030

4342

1969

 

 

 

70.1

 

1781

44.3

 

1125

48EJ,EWE034

 

 

 

 

 

 

 

 

 

 

 

48EJ,EK,EW,EYD038

4442

2015

 

 

 

92.7

 

2355

46.9

 

1191

48EJ,EWE038

4602

2087

 

 

 

94.1

 

2390

47.2

 

1199

48EJ,EK,EW,EYD044

4668

2117

150

 

3810

89.3

 

2268

46.9

 

1191

48EJ,EWE044

4828

2190

 

90.8

 

2306

47.2

 

1199

 

 

 

 

 

48EJ,EK,EW,EYD048

4955

2248

 

 

 

87.7

 

2228

46.5

 

1181

48EJ,EWE048

5115

2320

 

 

 

89.2

 

2266

46.8

 

1189

NOTICE TO RIGGERS:

ALL PANELS MUST BE IN PLACE

WHEN RIGGING.

NOTE: Rig with four cables and spread with two 92 in. (2337 mm) spreader bars. Maintain a dis- tance of 74 in. (1880 mm) from top of unit to eyehook.

NOTE:

Add 32 lb (14.5 kg) for domestic crating.

Add 312 lb (142 kg) for export crating (024-034 units).

Add 346 lb (157 kg) for export crating (038-048 units).

Add 250 lb (113 kg) for power exhaust.

Add 220 lb (100 kg) for copper condenser coil (024-034 units).

Add 285 lb (129 kg) for copper condenser coil (038,044 units).

Add 380 lb (172 kg) for copper condenser coil (048 unit).

Fig. 7 Ð Rigging Label

9

Image 9
Contents Installation, Start-Up Service Instructions Instructions on Field Fabricate DuctworkDegrees and Inches Unit Leveling Tolerances DimensionsRoof Curb Sizes Weight Unit OperatingSize 48EJE038 Ft-in 48EJ,EKD03848EJ,EKD044 48EJE044Base Unit Dimensions, 48EW,EY024-034 Base Unit Dimensions, 48EW,EY038-048 48EJ,EK,EW,EYD028 48EJ,EK,EW,EYD030 Unit Weight 48EJ,EK,EW,EYD02448EJ,EK,EW,EYD034 48EJ,EK,EW,EYD038Unit 48EJ,EK,EW,EY Physical Data4442/4602 4668/4828 4955/5115 Air Distribution Ð Thru-the-Bottom Combustion Fan Housing Location VAV Unit Configuration Default Cooling Default HeatingField Control Remote Start/Stop Make Electrical Connections CCN SIOLED Electrical Data RLA LRAFLA LRA MCA Mocp FLA FLA LRAHacr NEC044 QtyHeating, Air Conditioning Minimum Circuit AmpsTerminal Block GND Ð GroundPEC DIPManufacturer Cable Part no CCN Connection Approved Shielded Cables2413 or 8772Color Code Recommendations Make Outdoor-Air Inlet AdjustmentsRED WhiteAdding Seal Strip to Top of Hood Sides Adding Foam Strip to Hood Side Mounting Angle With Tabs Attached to Filter Track Assembly Psychrometric Chart for Enthalpy Control Barometric Relief Damper and Power Exhaust Mounting Details Pressure Transducer Locations START-UP VFD Supply Air Pressure Set Point Pressure Control VFDSET Point Potentiometer Signal Levels Direct Digital Controls DIP Switch ConguraBuilding Pressure Signal Level VdcPower Exhaust Default Set Points DIP Switch CongurationDIP Switch Factory Settings Airflow 17,000 16,00018,000 19,000528 572 615 656 695 733 769 805 Motor Limitations Fan Performance Ð Power ExhaustESP Standard Efficiency MotorsAir Quantity Limits Sequence of OperationUser Dened Set Points GAS HEATING, Variable AIR Volume VAV Units DEG. F Reset COMHIR Device Pressurization Smoke Purge Evacuation Fire Shutdown Smoke Control ModesCooling Capacity Staging Table, CV Units With 2 Compressors StagesCompressor Manufacturer Lubricant LubricationTypical Gas Heating Section Evaporator Fan Service and ReplacementCondenser-Fan Adjustment Evaporator-Fan Motor ReplacementProtective Devices Belt Tension AdjustmentGas Valve IFC AHAIfcb TranTypical Power Schematic 48EJ,EK,EW,EY024-034 208/230-3-60 Typical VAV 115-v Control Circuit Typical CV 115-v Control Circuit Typical VAV 24-v Control Circuit Typical CV 24-v Control Circuit Troubleshooting Typical Refrigerant Circuiting 48EJ,EK,EW,EY038,044 Typical Refrigerant Circuiting 48EJ,EK,EW,EY048 IGC Control Heating and Cooling Control Board LED Alarms IGC Control Board LED AlarmsI/O Channel Designations Base Module Ð VAV I/O Channel Designations Base Module Ð CVTerminal no Assignment SPTPackaged Service Training START-UP Checklist General
Related manuals
Manual 118 pages 46.64 Kb

EW, EY024-048, EK, 48EJ specifications

The Carrier 48EJ, 48AW, 48EK, 48AJ, and 48EY024-068 are cutting-edge rooftop air conditioning units designed for commercial applications. These models are renowned for their reliability, energy efficiency, and innovative technologies aimed at providing optimal indoor comfort.

One of the standout features of these units is their advanced cooling and heating capabilities. They employ a multi-stage compressor system that allows for precise temperature control, accommodating various load requirements. This flexibility is particularly beneficial in commercial settings where the cooling load can fluctuate throughout the day.

Energy efficiency is paramount in today’s environmental landscape, and Carrier has ensured that these models meet stringent efficiency standards. They incorporate high-efficiency scroll compressors, which significantly reduce energy consumption while delivering powerful performance. The units are also equipped with variable speed fans that adjust airflow based on demand, further optimizing energy use.

In terms of construction, these rooftop units feature a robust design that enhances durability and longevity. The cabinet is constructed to withstand harsh weather conditions, ensuring reliable performance year-round. Additionally, the units are equipped with corrosion-resistant coatings, particularly useful in coastal environments where salt exposure can be a concern.

The Carrier 48EJ, 48AW, 48EK, 48AJ, and 48EY models utilize advanced controls and connectivity features, allowing for easy integration into building management systems. This connectivity enables remote monitoring and control, facilitating quick response to changing conditions and simplifying maintenance tasks.

Noise reduction is another key characteristic of these models. They are designed with sound-absorbing insulation and low-noise fan blades to ensure quiet operation, making them suitable for noise-sensitive environments such as schools and hospitals.

These units are also available with various options for air filtration and dehumidification. The use of high-efficiency air filters enhances indoor air quality by trapping dust, pollen, and other airborne particles. Enhanced dehumidification capabilities ensure that spaces remain comfortable even in humid conditions.

In conclusion, the Carrier 48EJ, 48AW, 48EK, 48AJ, and 48EY024-068 rooftop units are engineered to offer exceptional performance, energy efficiency, and durability. With their advanced technologies and user-friendly features, they stand out as reliable solutions for meeting diverse commercial cooling and heating needs, making them a popular choice for many businesses.