Bryant 580F operation manual

Page 25

Fig. 36 — Perfect Humidity™ Dehumidification Package Operation Diagram (Single Circuit Shown)

25

Image 25
Contents Safety Considerations ContentsInstallation Provide Unit Support Roof Curb Details 580F180-240 Roof Curb Details 580F300 II. RIG and Place Unit Alternate Unit SupportPositioning Roof Mount580F Ft-in 180 Unit Maximum Dimensions Shipping Weight210 240Base Unit Dimensions 580F180 Base Unit Dimensions 580F240 Base Unit Dimensions 580F300 Physical Data Furnace Section Power ExhaustFreeze Protection Thermostat F OUTDOOR-AIR Inlet ScreensIII. Field Fabricate Ductwork Install Flue Hood and Wind BaffleIV. Make Unit Duct Connections VI. Trap Condensate DrainVII. Orifice Change Field Control Wiring VIII. Install GAS PipingOptional Non-Fused Disconnect Optional Convenience Outlet Field Power Wiring ConnectionsXI. Install OUTDOOR-AIR Hood Make OUTDOOR-AIR Inlet Adjust MentsElectrical Data Manual Outdoor-Air DamperOutdoor-Air Hood Component Location XII. Install ALL AccessoriesMotormaster V Control Package Usage Motormaster V Control Installation 580F240Applicable Voltages and Motors Return Air Pressure Drop in. wg Outdoor Air Damper LeakageEconoMi$erIV Standard Sensors CFMEconoMi$erIV Control Modes Temperature FEconoMi$erIV Controller Potentiometer LED Locations EconoMi$erIV Sensor UsageEnthalpy Changeover Set Points EconoMi$erIV Controller CO2 Sensor Standard Settings LPS LlsvTran Page VI. Internal Wiring IV. Refrigerant Service PortsSTART-UP Unit PreparationAirflow Fan Performance 580F180275 Low Heat Units7200 7500 Fan Performance 580F180360 High Heat UnitsFan Performance 580F210360 High Heat Units Fan Performance 580F210275 Low Heat UnitsRpm Bhp Watts 500 Rpm Watts Bhp 000 Fan Performance 580F240275 Low Heat Units500 000 10,000 000 500 10,000 Fan Performance 580F240360 High Heat UnitsFan Performance 580F300360 High Heat Units Fan Performance 580F300275 Low Heat UnitsGeneral Notes for FAN Performance Data Tables Fan Rpm at Motor Pulley Settings Accessory/FIOP Static Pressure in. wg 580F180-300Air Quantity Limits Evaporator-Fan Motor DataXIII. Operating Sequence Service CleaningII. Lubrication IV. Evaporator FAN Service and ReplacementVI. CONDENSER-FAN Adjustment Belt Tension AdjustmentVII. Power Failure VIII. Refrigerant ChargePerfect Humidity System Charging IX. GAS Valve AdjustmentNatural Gas Main BurnersXVII. Optional Hinged Access Doors XV. Replacement PartsXI. Filter Drier XII. Protective DevicesSpark Gap Adjustment Typical Wiring Schematic 580F240, 208/230 V Shown Typical Component Arrangement 580F240 Shown CLO AHAComp EquipII. ECONOMI$ERIV Troublshooting Troubleshooting Unit TroubleshootingHeating Service Analysis EconoMi$erIV Troubleshooting CompletionProblem Cause Remedy Cooling Service Analysis IGC Control Heating and Cooling Inputs Outputs EconoMi$erIV Input/Output LogicDemand Control Enthalpy Terminal†Index HumidistatCall for Free Catalog Service TrainingCopyright 2006 Bryant Heating & Cooling Systems Catalog no Page Temperatures START-UP ChecklistPRE-START-UP II. START-UP Electrical
Related manuals
Manual 80 pages 29.14 Kb Manual 64 pages 4.35 Kb

580F specifications

The Bryant 580F is a highly regarded gas furnace known for its exceptional heating performance and advanced technology. Designed for residential use, this model stands out for its reliability, efficiency, and user-friendly features that cater to modern heating demands.

One of the most notable features of the Bryant 580F is its efficiency rating. With an AFUE (Annual Fuel Utilization Efficiency) rating of up to 95%, this furnace maximizes heat output while minimizing energy consumption. This high level of efficiency not only results in lower utility bills but also reduces the environmental impact—a critical consideration for today’s eco-conscious homeowners.

The Bryant 580F is equipped with a multi-speed blower that ensures consistent airflow and enhances comfort by maintaining even temperatures throughout the home. This technology allows the furnace to adjust its operation based on the heating needs, leading to quieter operation and increased comfort levels.

In terms of construction, the Bryant 580F is built with durable materials that promise longevity and resilience against wear and tear. Its compact design makes installation easier, allowing it to fit into tight spaces without compromising its performance.

One of the standout technologies integrated into the Bryant 580F is its enhanced control system. The furnace works seamlessly with smart thermostats, allowing homeowners to monitor and adjust heating settings from their mobile devices. This feature not only provides convenience but also allows for energy-saving optimizations based on personal schedules and preferences.

Safety is also a primary concern with the Bryant 580F. It includes robust safety features such as a hot surface ignition system that eliminates the need for a standing pilot light, reducing the risk of gas leaks. Additionally, advanced diagnostics help in troubleshooting and maintenance, ensuring that potential issues can be identified and resolved quickly.

In conclusion, the Bryant 580F gas furnace is a remarkable choice for those seeking a blend of efficiency, comfort, and advanced technology. Its high AFUE rating, multi-speed blower, smart control compatibility, and safety features make it a reliable option for homeowners looking to invest in a dependable heating solution. As the demand for energy-efficient heating continues to grow, the Bryant 580F stands out as a model that meets and exceeds expectations in the modern heating landscape.