Cleaning your humidifier regularly helps eliminate odors and bacterial and fungal growth. Ordinary household bleach is a good disinfectant and can be used to wipe out the humidifier base and reservoir after cleaning.

We recommend cleaning your humidifier at least once every two weeks to maintain optimum environmental conditions for your home.

We also recommend using Essick Air Bacteriostat Treatment each time you refill your humidifier to eliminate bacterial growth. Add bacteriostat according to the instructions on the bottle. Please call 1-800-547-3888 to order Bacteriostat Treatment reference part#1970.

1)Turn off unit completely and unplug from outlet.

2)Lift out the chassis.

3)Take reservoir to cleaning basin. Lift wick from the reservoir allowing the water to drain. Rinse the wick under fresh water only. Do not use soap, detergent, or any other cleaners on the wick. Leave in sink to drain.

REMOVING SCALE

4)Empty the water from the reservoir. Fill reservoir ½ full with water and add 8 oz. (1 cup) of white vinegar. Let stand 20 minutes. Then empty solution.

5)Dampen a soft cloth with white vinegar and wipe out reservoir to remove scale. Rinse the reservoir thoroughly with fresh water to remove scale and cleaning solution before disinfecting.

DISINFECTING UNIT

6)Fill the reservoir ½ full with water and add 1 teaspoon of bleach. Wet all surfaces on cabinet, then let solution stay for 20 minutes then rinse with water until bleach smell is gone. Dry with clean cloth. The outside of the unit may be wiped down with a soft cloth dampened with fresh water.

7)Refill unit and re-assemble per ASSEMBLY instructions.

SUMMER STORAGE

1)Clean unit as outlined in Care & Maintenance section.

2)Discard used wick and any water in the reservoir and allow unit to dry thoroughly before storage. Do not store with water inside reservoir.

3)Do not store unit in an attic or other high-temperature area.

4)Install new filter at beginning of season.

7

Image 7
Contents ED11 Series OWNER’S Care USE ManualIntroduction General Safety InstructionsDescription Know Your HumidifierCasters ASSEMBLY, Controls & OperationFloat and Wick Installation HOW Your Humidifier WorksOperation CHASSIS/POWER PackAIR Cleaning Filter Optional Important Filling InformationHumidity Control FAN SpeedOptional Aircare Filter Summer Storage Care and MaintenanceRemoving Scale Disinfecting UnitEssick AIR Products Humidifier Warranty Policy Guides ’UTILISATION & D’ENTRETIEN DU Propriétaire Instructions Générales De Sécurité Description ED11 FAMILIARISEZ-VOUS Avec Votre HumidificateurLES Roulettes Installation DU Flotteur ET DE LA MècheFonctionnement DE L’HUMIDIFICATEUR ASSEMBLAGE, Réglage ET FonctionnementRenseignements Importants SUR LE Remplissage VUE ArriereFiltre À AIR Optionnel Vitesse DE Ventilateur FonctionnementContrôle DE Lhumidité Désinfection DE L’APPAREIL Filtre Aircare OptionnelSoins ET Entretien DétartrageEssick AIR Products Politique DE Garantie Dhumidificateur Manual DE Cuidados USO DEL Propietario Modelo Instrucciones generales de seguridad Introducción Conoce SU HumidificadorDEL FILTRO/MECHA ENSAMBLAJE, Mandos Y OperaciónRuedas Instalación DEL Flotador YInformaciones Importantes Para EL Llenado CHASIS/UNIDAD DE FuerzaFiltro DE Aire Opcional Filtro Opcional Aircare Opcional Control DE LA HumedadOperación LA Velocidad DEL VentiladorEnsamblaje Almacenamiento Durante EL Verano Cuidados Y MantenimientoRemoción DE Sarro Desinfección DE LA UnidadGarantía DEL Essick AIR Humidificador

ED11 910, ED11 800 specifications

Essick Air is known for its commitment to quality and reliability in the realm of evaporative coolers, and the ED11 800 and ED11 910 models are prime examples of their innovative engineering. These units represent a formidable blend of performance, efficiency, and modern design, tailored to meet the cooling needs of various environments.

The Essick Air ED11 800 is designed to provide effective cooling for spaces up to 1,200 square feet. One of its standout features is the powerful 1/2 HP motor, which allows for optimal airflow and temperature control. The ED11 800 utilizes a unique, high-density evaporative media that maximizes the cooling process while minimizing water usage. This not only enhances energy efficiency but also creates a more environmentally friendly cooling solution compared to traditional air conditioning systems.

In terms of technology, the ED11 800 is equipped with a convenient, adjustable airflow system. Users can customize the direction and intensity of the airflow, ensuring that cooling is directed exactly where it is needed most. Additionally, the model features a built-in large water reservoir, which allows for extended operation without frequent refills.

On the other hand, the Essick Air ED11 910 offers a higher cooling capacity suitable for larger spaces of up to 1,500 square feet. Similar to the ED11 800, this model boasts a robust motor and efficient evaporative media. The ED11 910 takes it a step further with its advanced digital control panel, which offers intuitive programming and an easy-to-read display. Users can set precise temperature levels and monitor settings such as fan speeds and timer functions, providing a higher level of control over their indoor climate.

Both models are designed with the user in mind, featuring a sleek, modern aesthetic that fits seamlessly into various settings, from homes to commercial spaces. They are also easy to transport, equipped with durable wheels that facilitate movement from one room to another or even outdoors.

In conclusion, the Essick Air ED11 800 and ED11 910 are excellent options for individuals seeking efficient and effective evaporative cooling solutions. With their advanced technologies, user-friendly features, and commitment to performance, these models continue to uphold Essick Air’s reputation as a leader in the cooling industry. Investing in either model ensures a comfortable environment, even in the warmest months.