Kidde PI2000CA manual Hush Control Feature

Page 14

Operation

Hush® Control Feature

Smoke alarms are designed to minimize nuisance alarms. Cigarette smoke will not normally set off the alarm, unless the smoke is blown directly into the alarm. Combustion particles from cooking may set off the alarm if the alarm is located close to the cooking area. Large quantities of combustible particles are generated from spills or when broiling. Using the fan on a range hood that vents to the outside (non-recirculating type) will also help remove these combustible particles from the kitchen. The Hush® button is extremely useful in a kitchen area or other areas prone to nuisance alarms.

The Hush® feature has the capability of temporarily desensitizing the smoke alarm circuit for about 8 minutes. This feature is to be used only when a known alarm condition, such as smoke from cooking, activates the alarm.

If the alarm does sound, check for fires first. If a fire is discovered, get out and call the fire department. If no fire is present, check to see if one of the reasons listed in Locations to Avoid may have caused the alarm.

The smoke alarm is desensitized by pushing the Hush® button on the smoke alarm cover. If the smoke is not too dense, the alarm will silence immediately and the red LED will flash every 2 seconds for approximately 8 minutes. This indicates that the alarm is in a temporarily desensitized condition. The smoke alarm will automatically reset after approximately 8 minutes. If after this period particles of combustion are still present, the alarm will sound again.

The Hush® feature can be used repeatedly until the air has been cleared of the condition causing the alarm. Pushing the Test button on the alarm will end the alarm silencing period.

NOTE: Dense smoke will override the Hush® feature and sound a continuous alarm.

CAUTION: Before using the Hush® feature, identify the source of the smoke and be certain a safe condition exists.

13

Image 14
Contents Dual Sensor Contents IntroductionInstallation HD135FCARecommended Locations Image 1A Image 1B Locations to Avoid Ceilingminimum Wiring Requirements Mobile HomesWiring Instructions Wires on Alarm Harness Mounting Image 5 Attaching the AC QUICK-CONNECT Wire Harness Operation BatteryTesting Hush Control Feature Alarm Tamper-Resist Feature LED Indicators Smoke Sensing Chamber OperationAlarm Memory When Units Are InterconnectedBattery Replacement MaintenanceAlarm Removal Cleaning the Alarm Replacing the AlarmFire Safety Limitations of Smoke AlarmsGood Safety Habits What To Do When The Alarm Sounds NRC InformationAdditional Recommendations Warranty Year Limited Warranty

PI2000CA specifications

The Kidde PI2000CA is a state-of-the-art smoke and carbon monoxide detector designed to provide comprehensive safety for your home or business. This versatile device integrates advanced technologies to detect both smoke and carbon monoxide, ensuring peace of mind for occupants.

One of the most notable features of the Kidde PI2000CA is its dual-sensor technology. The smoke detection system utilizes both photoelectric and ionization sensors. The photoelectric sensor is highly effective at detecting smoldering fires, which are often characterized by excessive smoke and slow burning. In contrast, the ionization sensor excels in identifying fast-flaming fires. This combination allows the PI2000CA to offer superior responsiveness, providing reliable alerts in various fire scenarios.

Another defining characteristic of the PI2000CA is its 10-year sealed lithium battery. This feature eliminates the hassle of battery replacements, ensuring that the unit remains functional and reliable throughout its lifespan. The sealed battery also enhances convenience, as users no longer need to worry about battery expiration dates or regular checks.

The Kidde PI2000CA is also equipped with a voice alarm feature. In addition to standard visual alerts, the device announces the type of danger detected: "Fire" or "Warning: Carbon Monoxide." This auditory feature is particularly beneficial during nighttime or in situations where individuals may be disoriented, providing clear instructions that allow for quicker responses.

Furthermore, the smoke and carbon monoxide detector has a test/reset button, allowing users to regularly check the unit’s functionality. The device is designed to be user-friendly, making it easy for anyone to operate and maintain.

Another significant aspect of the Kidde PI2000CA is its user manual, which guides homeowners in optimal placement of the detector for effective coverage. Proper installation is crucial in maximizing the unit's performance, especially in larger spaces.

In summary, the Kidde PI2000CA combines innovative technology and user-centric features to offer enhanced safety for environments where smoke or carbon monoxide may pose risks. With its dual-sensor technology, long-lasting battery, voice alerts, and ease of maintenance, this device is a robust solution for smoke and CO detection, ensuring that families and individuals can feel safe in their homes.