Kidde PI2000CA manual Wiring Instructions

Page 9

Installation

Wiring Instructions

CAUTION! Turn off the main power to the circuit before wiring the alarm.

For alarms that are used as single station, DO NOT CONNECT THE RED WIRE TO ANYTHING. Leave the red wire insulating cap in place to make certain that the red wire cannot contact any metal parts or the electrical box.

When alarms are interconnected, all interconnected units must be powered from a single circuit.

A maximum of 24 Kidde devices may be interconnected in a multiple station arrangement. The interconnect system should not exceed the NFPA interconnect limit of 12 smoke alarms and/or 18 alarms total (smoke, heat, carbon monoxide, etc.) With 18 alarms interconnected, it is still possible to interconnect up to a total of 6 remote signaling devices and/or relay modules.

CAUTION! Kidde alarm and accessories CAN ONLY BE interconnected with other Kidde alarms and accessories as well as specified brands and models of interconnect compatible alarms. Connection of Kidde products to a non-specified manufacturer’s interconnect system, or connection with non-specified equipment from another manufacturer into an existing Kidde system could result in nuisance alarming, failure to alarm, or damage to one or all of the devices in the interconnect system. Refer to the User’s Guide supplied with each Kidde product for interconnect compatible models, brands, and devices.

When mixing models which have battery backup with models without battery backup, be advised that the models without battery backup will not respond during an AC power failure.

The maximum wire run distance between the first and last unit in an interconnected system is 305 m (1000').

Image 3 illustrates interconnection wiring. Improper connection will result in damage to the alarm, failure to operate, or a shock hazard.

Make certain alarms are wired to a continuous (non-switched) power line. NOTE: Use standard CSA listed household wire (as required by local codes) available at all electrical supply stores and most hardware stores.

8

Image 9
Contents Dual Sensor Introduction ContentsHD135FCA InstallationRecommended Locations Image 1A Image 1B Locations to Avoid Ceilingminimum Mobile Homes Wiring RequirementsWiring Instructions Wires on Alarm Harness Mounting Image 5 Attaching the AC QUICK-CONNECT Wire Harness Battery TestingOperation Hush Control Feature Alarm Tamper-Resist Feature Smoke Sensing Chamber Operation LED IndicatorsWhen Units Are Interconnected Alarm MemoryMaintenance Alarm RemovalBattery Replacement Replacing the Alarm Cleaning the AlarmLimitations of Smoke Alarms Fire SafetyGood Safety Habits NRC Information What To Do When The Alarm SoundsAdditional Recommendations Year Limited Warranty Warranty

PI2000CA specifications

The Kidde PI2000CA is a state-of-the-art smoke and carbon monoxide detector designed to provide comprehensive safety for your home or business. This versatile device integrates advanced technologies to detect both smoke and carbon monoxide, ensuring peace of mind for occupants.

One of the most notable features of the Kidde PI2000CA is its dual-sensor technology. The smoke detection system utilizes both photoelectric and ionization sensors. The photoelectric sensor is highly effective at detecting smoldering fires, which are often characterized by excessive smoke and slow burning. In contrast, the ionization sensor excels in identifying fast-flaming fires. This combination allows the PI2000CA to offer superior responsiveness, providing reliable alerts in various fire scenarios.

Another defining characteristic of the PI2000CA is its 10-year sealed lithium battery. This feature eliminates the hassle of battery replacements, ensuring that the unit remains functional and reliable throughout its lifespan. The sealed battery also enhances convenience, as users no longer need to worry about battery expiration dates or regular checks.

The Kidde PI2000CA is also equipped with a voice alarm feature. In addition to standard visual alerts, the device announces the type of danger detected: "Fire" or "Warning: Carbon Monoxide." This auditory feature is particularly beneficial during nighttime or in situations where individuals may be disoriented, providing clear instructions that allow for quicker responses.

Furthermore, the smoke and carbon monoxide detector has a test/reset button, allowing users to regularly check the unit’s functionality. The device is designed to be user-friendly, making it easy for anyone to operate and maintain.

Another significant aspect of the Kidde PI2000CA is its user manual, which guides homeowners in optimal placement of the detector for effective coverage. Proper installation is crucial in maximizing the unit's performance, especially in larger spaces.

In summary, the Kidde PI2000CA combines innovative technology and user-centric features to offer enhanced safety for environments where smoke or carbon monoxide may pose risks. With its dual-sensor technology, long-lasting battery, voice alerts, and ease of maintenance, this device is a robust solution for smoke and CO detection, ensuring that families and individuals can feel safe in their homes.