Kidde PI2000CA manual Recommended Locations

Page 4

Installation

Recommended Locations

Locate the first alarm in the immediate area of the bedrooms. Try to monitor the exit path, as the bedrooms are usually farthest from the exit. If more than one sleeping area exists, locate additional alarms in each sleeping area (Image 1A).

Locate additional alarms to monitor any stairway as stairways act like chimneys for smoke and heat.

Locate at least one alarm on every floor level (Image 1B).

Locate an alarm in every bedroom.

Locate an alarm in every room where electrical appliances are operated (i.e. portable heaters or humidifiers).

Locate an alarm in every room where someone sleeps with the door closed. The closed door may prevent an alarm not located in that room from waking the sleeper.

Smoke, heat, and combustion products rise to the ceiling and spread horizontally. Mounting the smoke alarm on the ceiling in the centre of the room places it closest to all points in the room. Ceiling mounting is preferred in ordinary residential construction.

When mounting an alarm on the ceiling, locate it at a minimum of 10 cm (4") from the side wall (Image 2A).

When mounting the alarm on the wall, use an inside wall with the top edge of the alarm at a minimum of 10 cm (4") and a maximum of 30.5 cm (12") below the ceiling (Image 2A).

Put smoke alarms at both ends of a bedroom hallway or large room if the hallway or room is more than 9.1 m (30') long.

For mobile home installation, select locations carefully to avoid thermal barriers that may form at the ceiling. For more details, see Mobile Homes.

3

Image 4
Contents Dual Sensor Contents IntroductionInstallation HD135FCARecommended Locations Image 1A Image 1B Locations to Avoid Ceilingminimum Wiring Requirements Mobile HomesWiring Instructions Wires on Alarm Harness Mounting Image 5 Attaching the AC QUICK-CONNECT Wire Harness Testing BatteryOperation Hush Control Feature Alarm Tamper-Resist Feature LED Indicators Smoke Sensing Chamber OperationAlarm Memory When Units Are InterconnectedAlarm Removal MaintenanceBattery Replacement Cleaning the Alarm Replacing the AlarmFire Safety Limitations of Smoke AlarmsGood Safety Habits What To Do When The Alarm Sounds NRC InformationAdditional Recommendations Warranty Year Limited Warranty

PI2000CA specifications

The Kidde PI2000CA is a state-of-the-art smoke and carbon monoxide detector designed to provide comprehensive safety for your home or business. This versatile device integrates advanced technologies to detect both smoke and carbon monoxide, ensuring peace of mind for occupants.

One of the most notable features of the Kidde PI2000CA is its dual-sensor technology. The smoke detection system utilizes both photoelectric and ionization sensors. The photoelectric sensor is highly effective at detecting smoldering fires, which are often characterized by excessive smoke and slow burning. In contrast, the ionization sensor excels in identifying fast-flaming fires. This combination allows the PI2000CA to offer superior responsiveness, providing reliable alerts in various fire scenarios.

Another defining characteristic of the PI2000CA is its 10-year sealed lithium battery. This feature eliminates the hassle of battery replacements, ensuring that the unit remains functional and reliable throughout its lifespan. The sealed battery also enhances convenience, as users no longer need to worry about battery expiration dates or regular checks.

The Kidde PI2000CA is also equipped with a voice alarm feature. In addition to standard visual alerts, the device announces the type of danger detected: "Fire" or "Warning: Carbon Monoxide." This auditory feature is particularly beneficial during nighttime or in situations where individuals may be disoriented, providing clear instructions that allow for quicker responses.

Furthermore, the smoke and carbon monoxide detector has a test/reset button, allowing users to regularly check the unit’s functionality. The device is designed to be user-friendly, making it easy for anyone to operate and maintain.

Another significant aspect of the Kidde PI2000CA is its user manual, which guides homeowners in optimal placement of the detector for effective coverage. Proper installation is crucial in maximizing the unit's performance, especially in larger spaces.

In summary, the Kidde PI2000CA combines innovative technology and user-centric features to offer enhanced safety for environments where smoke or carbon monoxide may pose risks. With its dual-sensor technology, long-lasting battery, voice alerts, and ease of maintenance, this device is a robust solution for smoke and CO detection, ensuring that families and individuals can feel safe in their homes.