Kidde PI2000CA manual Installation, HD135FCA

Page 3

Installation

This unit is suitable as a single station and/or multiple station alarm (interconnects with up to 24 devices), and has a five-year limited warranty.

IMPORTANT:This unit is only approved to interconnect with the Kidde line of products. It is not approved to interconnect with any other manufacturer’s products.

This alarm is interconnect compatible with the following alarms and accessories:

Smoke alarms:

1235CA, 1275CA, 1276CA, 1285CA,

 

i12020CA, i12040CA, i12060CA,

 

PE120CA, PI2000CA

Smoke/CO alarms: KN-COSM-IBCA, KN-COSM-ICA

CO alarms:

KN-COB-ICB-CA, KN-COB-IC-CA

Relay modules:

120X, SM120X, CO120X

Heat alarm:

HD135FCA

Strobe Light:

SL177I

Refer to respective manuals for specific application information.

This product is designed to detect products of combustion using both an ionization sensor and a photoelectric sensor. The ionization sensor contains 0.9 microcurie of Americium 241, a radioactive material. Distributed under U.S. NRC License No. 32-23858-01E. Manufactured in compliance with U.S. NRC safety criteria in 10 CFR 32.27. The purchaser is exempt from any regulatory requirements. Do not try to repair the smoke alarm yourself. Refer to the instructions in Warranty for service.

ELECTRICAL RATING: 120 V AC, 60 HZ, 80 mA maximum per alarm (maximum 80 mA for originating unit with 24 devices interconnected).

WARNING! Battery door will not close unless battery is present. Removal of the smoke alarm battery and disconnecting or loss of A.C power will render the smoke alarm inoperative.

IMPORTANT! Read all instructions before installation and keep this manual near the alarm for future reference.

2

Image 3 Contents
Dual Sensor Introduction ContentsHD135FCA InstallationRecommended Locations Image 1A Image 1B Locations to Avoid Ceilingminimum Mobile Homes Wiring RequirementsWiring Instructions Wires on Alarm Harness Mounting Image 5 Attaching the AC QUICK-CONNECT Wire Harness Battery TestingOperation Hush Control Feature Alarm Tamper-Resist Feature Smoke Sensing Chamber Operation LED IndicatorsWhen Units Are Interconnected Alarm MemoryMaintenance Alarm RemovalBattery Replacement Replacing the Alarm Cleaning the AlarmLimitations of Smoke Alarms Fire SafetyGood Safety Habits NRC Information What To Do When The Alarm SoundsAdditional Recommendations Year Limited Warranty Warranty