Bacharach AGM300 manual ADM800 AC Input Power and Ground Connections

Page 33

ADM800 AC Input Power and Ground Connections

Instruction 3015-4275

25

Image 33 Contents
Rev May AGM300 / ADM800 Ammonia Gas Monitoring SystemInstruction Table of Contents How to Use This Manual IntroductionPlease Read this Manual Carefully Before Use Safety Precautions Installation Category Hazard Symbols on MonitorCleaning Altitude LimitGeneral Description Functional OverviewCommunication Options Suggested Location of Sampling PointsMachine Room ChillerLED Standard Accessories for a 4 Point SystemAGM300 Installation Considerations Locating the MonitorInspection AGM300 Mounting Instructions InstallationScrew Locations AGM300 Mounting SpecsOverview AGM300 Connecting Air LinesAGM300 Side View Inlet / Purge PortsConnecting Exhaust Line Connecting Purge LineConnecting Sample Intake Lines Tubing ConsiderationsAGM300 Interior Schematic Switches / Fuses Do not Apply PowerON/OFF / OUTVAC Installation AGM300 Electrical WiringAGM300 AC Input Power and Ground Connections RS-485 Connector AGM300 Connecting Communication DevicesAmmonia Display Module ADM800 Connection Integrating with Building Management SystemsChanging Terminator Settings Personal Computer Refer to AGM300 PC Software SectionOUT Connecting to a Building Management System Multiple AGM’sRS-485 Connections Between AGM300’s AGM300 PC Software Programming the AGM300 Using PC SoftwareMultiple AGM300’s Connected to a Building Management System Unit Node Terminator Outout Building Management SystemTo Open a Saved Program Saving the AGM300 Program to a Disk or DriveTo Send a Saved Program to an AGM300 Trend DataSealevel SYSTEMS, INC USB Type LaptopsAGM300 Current Loop Interfaces Current Loop ConnectorOptional 4-20 mAdc Outputs ConnectionAGM300 Relay Connector AGM300 Connecting External AlarmsTypical AGM300 Relay 1 and Relay 2 Wiring Leak Spill Evacuate FaultADM800 Oblique Photo ADM800 InstallationADM800 Installation Considerations ADM800 Mounting Specs ADM800 Mounting InstructionsFront Panel Chassis ADM800 Interior SchematicTo Host To MonitorsADM800 Electrical Wiring ADM800 AC Input Power and Ground Connections ADM800 Communication Connections AGM300 NetworkIntegration with Building Management System To Monitor Changing Terminator Switch SettingsADM800 Relay Connector ADM800 Connecting External AlarmsADM800 Operation ADM800 Exterior SchematicADM800 Overview System Screen ADM800 Screen DisplaysSetup Parameters Password ProtectionADM800 System Programming ADM800 Setup Programming Setting the ClockClock Setup Screen Contrast Navigating to the 1st ADM Setup ScreenNumber of AGM Units AGM Baud RatePassword Audible AlarmEnabling Building Management System Connection Building Management System Stop BitsSetting Relay Parameters Navigating to the 2nd ADM Setup ScreenADM Setup Screen #2 AGM Node AddressNavigating to the 1st and then 2nd AGM Setup Screen AGM300 Setup ProgrammingScreen #1 AGM Setup Screen #1 AGM Setup Screen #2Alarm Ack Mode Number of Zones InstalledLocation Zone Hold TimeLoop 2 Factor Re-Zero ModeAuto Zone ChangeNavigating to the 3rd AGM Setup Screen Service TimeoutAGM Setup #3 Screen Navigating to the 1st Zone Setup Screen ADM800 Zone Setup ProgrammingZone Setup Screen #1 DistanceNavigating To the 2nd Zone Setup Screen Average TemperatureCurrent PPM Log IntervalRe-Setting the Peak PPM Value Spill LevelEvacuation Level Functional Overview General OperationWorking with the Zone Screen Zone ScreenZone Screen Alarm Mode Zone Screen Hold ModeFault Conditions Working with the System Screen System Screen Alarm ModeAlarm Log Screen AGM Setup #1 ScreenSystem Screen Fault Mode Working with Alarms Responding To AlarmsAlarm Summary Screen Alarm Detail Screen Alarm Detail ScreenAlarm Summary Screen Acknowledge Mode Acknowledging AlarmsOverview Log Interval Working with the Trend ScreenNavigating To the Trend Screen Trend ScreenWorking with System Faults Navigating to the Fault ScreenFault Screen Critical Faults Reset to Factory Default SettingsClearing System Faults Viewing Fault LogFault Log Screen Working with the Calibration Screen Adjusting Calibration FactorNavigating to the Calibration Screen Calibration ScreenCalibration Procedure Navigating to the Diagnostic Screen Working with the Diagnostic ScreenDiagnostic Screen Overview Diagnostic ScreenInstruction System Screen Service Mode Service ModeInstruction Appendix Servicing Inline Filter AGM300 / ADM800 MaintenanceServicing Air Lines Replacing FusesOptional Accessories Intake ManifoldsMA Interface Board ADM800 Logic Diagram Modbus RTU Protocol RS-485 Communication ProtocolProtocol Details AGM300 Modbus RTU OperationKey Comm Protocol Parameters Modbus Mode RTU onlyData Type Abbreviations Summary of RegistersRegister Name Number Type Description TIMUnused TIM REVUnused Minutes RS-485BAUDMode. do not Modify use zone hold register or Service mode register to change this parameterMSB LSBZone Data Register 0x12xxh R/W 78 bytes Variable Type Length DescriptionGood. do not Modify Instruction Instruction Stpppm To Release the Zone Hold Use the Following Sequence of Steps Fault Log Register Register 0x1900, 0x1901h Bytes Instruction Point to current reading Time record for each of the 100 log points. The formatLast 100 log points 2 byes per point Warranty and Service WarrantyService Return Procedure Products Covered under Warranty and Service PolicyField Repair AGM300 Specifications ADM800 Specifications Instruction Headquarters Hunt Valley Circle, New Kensington, PA