Bacharach ADM800, AGM300 manual Working with System Faults, Navigating to the Fault Screen

Page 62

Working with System Faults

Functional Overview

If a system malfunction occurs, the AGM300 will detect the problem and cause its yellow FAULT LED to glow. Additionally, an external alarm device may activate and an audible alarm may sound if those features have been enabled (Pages 17 & 38).

The next time the ADM800 polls the affected monitor its yellow FAULT LED will also glow. Additionally, an external alarm device may activate and an audible alarm may sound if those features have been enabled (Pages 28 & 35).

Depending on the nature of the fault, the AGM300 may or may not continue to operate normally. Under a non- critical fault condition, the AGM300 will continue to measure and log data, but some peripheral functions may be compromised. Under a critical fault condition, action is required for the AGM300 to operate normally. The table on the following page lists the various fault conditions and explains what action should be taken to correct the problem.

Navigating to the Fault Screen

First, display the System Screen (Page 31). Next, press the key adjacent to the target AGM300 unit to go to that monitor’s AGM Setup Screen #1 (Page 37). Finally, press the FAULTS key to display the Fault Screen of the selected monitor.

Fault Screen

54

Instruction 3015-4275

Image 62
Contents AGM300 / ADM800 Ammonia Gas Monitoring System Rev MayInstruction Table of Contents Please Read this Manual Carefully Before Use How to Use This ManualIntroduction Safety Precautions Cleaning Hazard Symbols on MonitorInstallation Category Altitude LimitCommunication Options Functional OverviewGeneral Description Suggested Location of Sampling PointsChiller Machine RoomStandard Accessories for a 4 Point System LEDInspection AGM300 Installation ConsiderationsLocating the Monitor Screw Locations InstallationAGM300 Mounting Instructions AGM300 Mounting SpecsAGM300 Side View AGM300 Connecting Air LinesOverview Inlet / Purge PortsConnecting Sample Intake Lines Connecting Purge LineConnecting Exhaust Line Tubing ConsiderationsAGM300 Interior Schematic ON/OFF Do not Apply PowerSwitches / Fuses / OUTAGM300 Electrical Wiring VAC InstallationAGM300 AC Input Power and Ground Connections Ammonia Display Module ADM800 Connection AGM300 Connecting Communication DevicesRS-485 Connector Integrating with Building Management SystemsOUT Changing Terminator SettingsPersonal Computer Refer to AGM300 PC Software Section RS-485 Connections Between AGM300’s Connecting to a Building Management SystemMultiple AGM’s Multiple AGM300’s Connected to a Building Management System Programming the AGM300 Using PC SoftwareAGM300 PC Software Unit Node Terminator Outout Building Management SystemTo Send a Saved Program to an AGM300 Saving the AGM300 Program to a Disk or DriveTo Open a Saved Program Trend DataUSB Type Laptops Sealevel SYSTEMS, INCOptional 4-20 mAdc Outputs Current Loop ConnectorAGM300 Current Loop Interfaces ConnectionAGM300 Connecting External Alarms AGM300 Relay ConnectorLeak Spill Evacuate Fault Typical AGM300 Relay 1 and Relay 2 WiringADM800 Installation ADM800 Oblique PhotoADM800 Installation Considerations ADM800 Mounting Instructions ADM800 Mounting SpecsADM800 Interior Schematic Front Panel ChassisTo Monitors To HostADM800 Electrical Wiring ADM800 AC Input Power and Ground Connections Integration with Building Management System ADM800 Communication ConnectionsAGM300 Network Changing Terminator Switch Settings To MonitorADM800 Connecting External Alarms ADM800 Relay ConnectorADM800 Exterior Schematic ADM800 OperationADM800 Overview ADM800 Screen Displays System ScreenADM800 System Programming Setup ParametersPassword Protection Clock Setup Screen ADM800 Setup ProgrammingSetting the Clock Number of AGM Units Navigating to the 1st ADM Setup ScreenContrast AGM Baud RateEnabling Building Management System Connection Audible AlarmPassword Building Management System Stop BitsADM Setup Screen #2 Navigating to the 2nd ADM Setup ScreenSetting Relay Parameters AGM Node AddressScreen #1 AGM Setup Screen #1 AGM300 Setup ProgrammingNavigating to the 1st and then 2nd AGM Setup Screen AGM Setup Screen #2Location Number of Zones InstalledAlarm Ack Mode Zone Hold TimeAuto Re-Zero ModeLoop 2 Factor Zone ChangeAGM Setup #3 Screen Navigating to the 3rd AGM Setup ScreenService Timeout Zone Setup Screen #1 ADM800 Zone Setup ProgrammingNavigating to the 1st Zone Setup Screen DistanceCurrent PPM Average TemperatureNavigating To the 2nd Zone Setup Screen Log IntervalEvacuation Level Re-Setting the Peak PPM ValueSpill Level Working with the Zone Screen General OperationFunctional Overview Zone ScreenZone Screen Hold Mode Zone Screen Alarm ModeFault Conditions System Screen Alarm Mode Working with the System ScreenAGM Setup #1 Screen Alarm Log ScreenSystem Screen Fault Mode Alarm Summary Screen Working with AlarmsResponding To Alarms Alarm Detail Screen Alarm Detail ScreenAcknowledging Alarms Alarm Summary Screen Acknowledge ModeNavigating To the Trend Screen Working with the Trend ScreenOverview Log Interval Trend ScreenFault Screen Working with System FaultsNavigating to the Fault Screen Reset to Factory Default Settings Critical FaultsFault Log Screen Clearing System FaultsViewing Fault Log Navigating to the Calibration Screen Adjusting Calibration FactorWorking with the Calibration Screen Calibration ScreenCalibration Procedure Diagnostic Screen Overview Working with the Diagnostic ScreenNavigating to the Diagnostic Screen Diagnostic ScreenInstruction Service Mode System Screen Service ModeInstruction Appendix Servicing Air Lines AGM300 / ADM800 MaintenanceServicing Inline Filter Replacing FusesMA Interface Board Optional AccessoriesIntake Manifolds ADM800 Logic Diagram RS-485 Communication Protocol Modbus RTU ProtocolAGM300 Modbus RTU Operation Protocol DetailsModbus Mode RTU only Key Comm Protocol ParametersRegister Name Number Type Description Summary of RegistersData Type Abbreviations TIMUnused REVUnused TIM Minutes RS-485BAUDMSB Service mode register to change this parameterMode. do not Modify use zone hold register or LSBGood. do not Modify Zone Data Register 0x12xxh R/W 78 bytesVariable Type Length Description Instruction Instruction Stpppm To Release the Zone Hold Use the Following Sequence of Steps Fault Log Register Register 0x1900, 0x1901h Bytes Instruction Last 100 log points 2 byes per point Point to current readingTime record for each of the 100 log points. The format Service Warranty and ServiceWarranty Field Repair Return ProcedureProducts Covered under Warranty and Service Policy AGM300 Specifications ADM800 Specifications Instruction Headquarters Hunt Valley Circle, New Kensington, PA

AGM300, ADM800 specifications

The Bacharach ADM 800 and AGM 300 are advanced analyzers designed for efficient monitoring and detection of gases in various applications. Known for their reliability and accuracy, these instruments cater to commercial and industrial sectors, ensuring safety and compliance with environmental regulations.

The Bacharach ADM 800 is a portable gas detection device renowned for its ability to detect multiple refrigerants. With a user-friendly interface, it features a high-resolution display that provides real-time data on refrigerant concentrations, allowing technicians to quickly identify leaks during maintenance operations. One of its standout technologies is a highly sensitive thermal conductivity sensor, which enables the ADM 800 to differentiate between various hydrocarbon refrigerants with precision.

Equipped with data logging capabilities, the ADM 800 can store and retrieve measurement data, making it an invaluable tool for tracking refrigerant trends over time. The device supports USB connectivity for easy transfer of data to computers, facilitating detailed reporting and analysis. Its robust design incorporates a protective casing that ensures durability in challenging work environments, making it ideal for both field use and stationary applications.

On the other hand, the Bacharach AGM 300 is specifically crafted for continuous gas monitoring in HVAC systems. This stationary device excels in measuring concentrations of gases such as CO, CO2, and various refrigerants, ensuring optimal performance and compliance. The AGM 300 uses advanced electrochemical sensors for precise gas measurements, providing real-time feedback and alerting users to any hazardous conditions.

One of the notable features of the AGM 300 is its ability to integrate seamlessly with building management systems, enabling centralized control and monitoring of gas levels across multiple locations. This connectivity enhances the safety of industrial and commercial spaces by allowing for automated responses to detected gas levels, which can significantly mitigate risks associated with gas leaks.

Both models emphasize user-centric design, with intuitive interfaces and clear displays, making them accessible even to those with minimal training. Additionally, their low maintenance requirements and long sensor life contribute to reduced operational costs.

In conclusion, the Bacharach ADM 800 and AGM 300 are exemplary solutions for gas detection and monitoring. Their advanced technologies, robust features, and user-friendly designs make them indispensable for ensuring safety and regulatory compliance in various environments.