BRK electronic Mx-1000 manual User Controls and Indications

Page 25

14 User Controls and Indications

14.1User Indications [showing optional clock module]

General Indicator Section

Indicator Description

Colour

Operating Condition

 

 

 

 

 

Power Supply On

Green

Steady indication for Mains or Standby power On.

 

 

 

 

 

Fire

Red

Flashes on any new fire alarm condition, changing to a steady

 

 

 

indication on operation of Silence Alarms.

 

 

 

 

 

Fire Routing Active

Red

Steady indication when the Fire Routing Output is active.

 

 

 

 

 

General Fault

Yellow

Flashes for any fault condition.

 

 

 

 

 

Power Supply Fault

Yellow

Flashes for mains or standby power supply/charge fault

 

 

 

 

 

System Fault

Yellow

Steady indication to indicate Microcontroller or Memory Failure.

 

 

 

Flashes to indicate Engineer’s Configuration Mode active.

 

 

 

 

 

Earth Fault

Yellow

Flashes for any positive or negative power supply earth fault.

 

 

 

 

 

Fuse Fault

Yellow

Flashes for any auxiliary supply fuse failure

 

 

 

 

 

Repeater Fault

Yellow

Flashes for any Repeater fault or repeater communication fault,

 

 

 

 

 

Sounder Fault/Disabled

Yellow

Flashes for any sounder fault. Steady for sounders disabled.

 

 

 

 

 

Sounder Test

Yellow

Steady indication while sounder walk test is active.

 

 

 

 

 

Fire Protection Fault/Disabled

Yellow

Flashes for a fault on the Fire Protection Output. Steady when Fire

 

 

 

Protection Output is disabled.

 

 

 

 

 

Fire Routing Fault/Disabled

Yellow

Flashes for a fault on the Fire Routing Output. Steady when Fire

 

 

 

Routing Output is disabled.

 

 

 

 

 

Fault Routing Fault/Disabled

Yellow

Flashes for a fault on the Fault Routing Output. Steady when Fault

 

 

 

Routing Output is disabled.

 

 

 

 

 

POWER SUPPLY ON FIRE

FIRE ROUTING ACTIVE GENERAL FAULT POWER SUPPLY FAULT SYSTEM FAULT EARTH FAULT

FUSE FAULT REPEATER FAULT

EVACUATE TEST DISPLAY

SILENCE/

RESOUND ENABLE ALARMS

RESETDISABLE

SILENCETEST BUZZER

ZONE LOCATION

1

2

3

4

5

6

7

8

9

10

ZONE LOCATION

17

18

19

20

21

22

23

24

25

26

SOUNDER FAULT/DISABLED SOUNDER TEST

FIRE PROTECTION FAULT/DISABLED FIRE ROUTING FAULT/DISABLED FAULT ROUTING FAULT/DISABLED

DELAY

ON/OFF/

OVERRIDE

SELECT

ON/OFF

SELECT

11

12

13

14

15

16

27

28

29

30

31

32

0 1

21 : 18 : 05

D / N OFF

Access Controls Keyswitch:

User Instructions

Clock Module [Optional]:

0

– Controls Locked

Showing time and

1

– Controls Unlocked

Day/Night off

 

 

 

 

Back light flashes for

 

 

Clock Module fault.

Zone Location Indications

Indicator Description

Colour

Operating Condition

 

 

 

User Generated Zone Location Text

Red

Flashes when zone is in a fire condition, turning to steady on

 

 

operation of Silence Alarms.

 

 

 

User Generated Zone Location Text

Yellow

Flashes when zone is in a fault condition. Illuminates steady

 

 

when zone is disabled or in test.

 

 

 

Page 25 of 40

Image 25
Contents Technical Data Sheet List Of Contents List of Tables List Of FiguresInstall all field wiring and equipment Overview of Installation and CommissioningIntroduction Mx-1002 / Mx-1004 Internal View Internal Panel ViewsMx-1032 Internal View Page Typical Wiring Diagram Mx-1016 16 -Zone Typical Wiring Schematic2-16 Zone Motherboard Termination Details Circuit Connection Details16 Zone Expansion Board Termination Details C1627 Motherboard Layout Mx-1000 Series C1627 Motherboard FeaturesPower Supplies 10 Mx-1000 Series C1632 16-Zone Expansion Board FeaturesVisual indications 11.3 32-Zone Power Supply Features And Connections Battery DisconnectElectrical Safety InstallationElectrical Safety 12.2.1 Mx-1000 Series Panel Installation Instructions Installation InstructionsQuantity Description Type Page Installation And Connection Of The C1631 Repeater Interface Repeater Connection Diagram An Overview Of The Commissioning Procedure Commissioning ChecklistCommissioning IntroductionPre-Commissioning Wiring Check Configuration Powering upCommissioning Procedure Commissioning zones Commissioning the Fire Protection control signal Commissioning the Fire and Fault Routing OutputsCommissioning the Class Change Input Commissioning ancillary outputs Commissioning ancillary inputsCommissioning repeaters User Indications showing optional clock module User Controls and IndicationsUser Controls showing optional clock module Switch Functionality Button Availability DescriptionZone or Output Configuration Engineer’s Zone/Output Configuration ProcessOperating the Engineer’s functions Page Invalid Configuration conditions Engineer’s Zone/Output Configuration Time-out WarningList of configuration DIL switches and their functions Page Delay 2/2 2/3 2/4 2/5 Duration Delay Switch SettingsC1631 setting for repeater addresses C1631 setting for quantity of repeatersRepeater Quantity Repeater AddressEnable/disable earth fault monitoring Optional Clock Module Configuration and SettingStandard Module Engineer Mode To Zero the Alarm CounterHhmmss Time Set MM flashing Hhmmss OFF Time MM flashing C1651 Clock Module DIL switch 1 and Link 1 Settings Configuring the Clock ModuleLink DIL Switch Pole Position Selected Function Link Position Selected FunctionClock Module Error Messages 16.3 C1651 Clock Module PCB FeaturesWP DIL Switch Error Message Eeprom Error MessageROM Checksum Error message Eeprom 0 Error Eeprom 1 ErrorMechanical Mx-1000 Series Panel Repeater Specification Zone Mechanical, Electrical & Environmental SpecificationPowersonic Battery Mx-1000 Series Panel Repeater Specification Zone

Mx-1000 specifications

The BRK electronic Mx-1000 is an innovative and versatile device designed for both home and industrial use, primarily focusing on smoke and carbon monoxide detection. Its advanced features enhance safety, ensuring peace of mind for users in various environments.

One of the standout features of the Mx-1000 is its dual-sensor technology. It combines both photoelectric and ionization sensors, maximizing its ability to detect different types of smoke. Photoelectric sensors are highly effective at identifying smoldering fires, which are often associated with slow-burning materials. On the other hand, ionization sensors excel at detecting fast-flaming fires. This dual capability ensures comprehensive fire detection, making the Mx-1000 one of the most reliable devices in its category.

Another notable characteristic is its built-in carbon monoxide detector. Carbon monoxide is a silent killer, and the Mx-1000 addresses this threat by providing early warning signals when harmful levels of this gas are detected. The integration of both smoke and carbon monoxide detection in a single unit simplifies safety measures and reduces the number of devices required for home and workplace safety.

The Mx-1000 is equipped with advanced digital technology that enhances its functionality. A state-of-the-art microprocessor evaluates alarm conditions more intelligently, which minimizes the chances of false alarms. This feature is particularly beneficial for households that might experience frequent smoke triggers from cooking or other benign sources.

User-friendliness is a key design aspect of the Mx-1000. It features a clear LED display that indicates the operational status, and a simple test button allows users to verify functionality with ease. The device also features a low-battery indicator, ensuring users are always informed about its operational state.

Installation is straightforward, with options for both wall and ceiling mounting to accommodate various room layouts. The Mx-1000 is designed to appeal to a wide range of customers, from DIY enthusiasts to professional installers.

In addition to its technological advancements, the BRK electronic Mx-1000 is built with reliability in mind. Its durable construction is meant to endure various conditions, ensuring longevity and consistent performance over time. This combination of top-tier technology, user-friendly features, and robust design makes the Mx-1000 a trusted choice for those seeking comprehensive safety solutions in smoke and carbon monoxide detection.