BRK electronic Mx-1000 manual User Controls showing optional clock module

Page 26

14.2User Controls [showing optional clock module]

POWER SUPPLY ON FIRE

FIRE ROUTING ACTIVE GENERAL FAULT POWER SUPPLY FAULT SYSTEM FAULT EARTH FAULT

FUSE FAULT REPEATER FAULT

EVACUATE TEST DISPLAY

SILENCE/

RESOUND ENABLE ALARMS

RESETDISABLE

SILENCETEST BUZZER

ZONE LOCATION

1

2

3

4

5

6

7

8

9

10

ZONE LOCATION

17

18

19

20

21

22

23

24

25

26

SOUNDER FAULT/DISABLED

SOUNDER TEST

FIRE PROTECTION FAULT/DISABLED

FIRE ROUTING FAULT/DISABLED

FAULT ROUTING FAULT/DISABLED

0 1

21 : 18 : 05

D / N OFF

DELAY

ON/OFF/

OVERRIDE

SELECT

ON/OFF

SELECT

11

12

13

14

15

16

27

28

29

30

31

32

Access Controls Keyswitch:

0 – Controls Locked

1 – Controls Unlocked

Switch

Functionality

Button Availability

Description

 

 

 

 

 

Evacuate

Operates all sounders continuously and lights the Evacuated LED

When controls are unlocked

 

adjacent the button until the silence button is operated.

 

 

 

 

Silence/Resound

Following a fire alarm condition, 1st operation stops sounders. The

When controls are unlocked

Alarms

General Fire LED and the Zonal fire LED will change from flashing to

 

 

steady. 2nd operation restarts the previously silenced sounders.

 

 

 

 

Reset

Clears the panel display, resets the zones, outputs and operates the

When controls are unlocked and [if

 

reset relay.

silence before reset is configured]

 

 

alarms silence switch has been

 

 

operated.

 

 

 

Silence Buzzer

1] Press to stop the buzzer sounding in fire or fault conditions.

When controls are locked or

 

 

unlocked

 

2] In 2 Stage Delay Mode, with stage 1 delay running, press to start

When the panel is in the fire

 

stage 2 delay otherwise all delayed outputs operate when Stage 1 timer

condition and the delay is running.

 

times out.

Controls are locked or unlocked

 

 

 

Delay

1] Press once to Enable the delay mode, lighting the adjacent delay on

1] When controls are unlocked and

On/Off/Override

LED. Press again to disable the delay mode and turn off the LED

delay period is set to a value > 0.

 

2] Overrides the delay when delay is running, turning the delay mode

2] When the panel is in the fire

 

and the LED off. All delayed outputs will operate immediately.

condition and the delay is running.

 

 

 

Select On/Off

Enables the User select feature [Select ↑ Select ↓] for selection of zones

When controls are unlocked

 

or outputs via for disablement/re-enablement and also Day/Night On/Off

 

 

selection and setting current time on clock module (when fitted).

 

 

 

 

Test Display

Press to illuminates all LEDs on the display and operate the buzzer. All

When controls are locked or

 

indications remain active for approx 5 seconds after button release. Also

unlocked

 

displays alarm counter on clock module (when fitted).

 

 

 

 

Enable

Press to clear the disablement or test condition on a zone or output

When controls are unlocked, the

 

selected via the User Select feature.

Select switch has been operated

 

 

and a zone or output has been

 

 

selected.

 

 

 

Disable

Press to disable a zone or output selected via the User Select feature.

As above.

 

 

 

Test

Press to initiate the One Man Test on sounders or zones as selected via

As above.

 

the User Select feature.

 

 

 

 

Select ↑ Select ↓

Used to scroll the cursor indication through the zone and output fault

When controls are unlocked and

 

LEDs on the display to select a zone or output for disablement, or test.

the Select switch has been

 

[LED illuminated when Select Mode is active]. Also scrolls through clock

operated.

 

module menu (when fitted).

 

 

 

 

Page 26 of 40

Image 26
Contents Technical Data Sheet List Of Contents List Of Figures List of TablesIntroduction Overview of Installation and CommissioningInstall all field wiring and equipment Internal Panel Views Mx-1002 / Mx-1004 Internal ViewMx-1032 Internal View Page Mx-1016 16 -Zone Typical Wiring Schematic Typical Wiring Diagram16 Zone Expansion Board Termination Details Circuit Connection Details2-16 Zone Motherboard Termination Details Mx-1000 Series C1627 Motherboard Features C1627 Motherboard LayoutVisual indications 10 Mx-1000 Series C1632 16-Zone Expansion Board FeaturesPower Supplies Battery Disconnect 11.3 32-Zone Power Supply Features And ConnectionsInstallation Electrical SafetyElectrical Safety Quantity Description Type Installation Instructions12.2.1 Mx-1000 Series Panel Installation Instructions Page Installation And Connection Of The C1631 Repeater Interface Repeater Connection Diagram Commissioning Commissioning ChecklistAn Overview Of The Commissioning Procedure IntroductionPre-Commissioning Wiring Check Commissioning Procedure Powering upConfiguration Commissioning zones Commissioning the Class Change Input Commissioning the Fire and Fault Routing OutputsCommissioning the Fire Protection control signal Commissioning repeaters Commissioning ancillary inputsCommissioning ancillary outputs User Controls and Indications User Indications showing optional clock moduleSwitch Functionality Button Availability Description User Controls showing optional clock moduleOperating the Engineer’s functions Engineer’s Zone/Output Configuration ProcessZone or Output Configuration Page List of configuration DIL switches and their functions Engineer’s Zone/Output Configuration Time-out WarningInvalid Configuration conditions Page Delay Switch Settings Delay 2/2 2/3 2/4 2/5 DurationRepeater Quantity C1631 setting for quantity of repeatersC1631 setting for repeater addresses Repeater AddressStandard Module Engineer Mode Optional Clock Module Configuration and SettingEnable/disable earth fault monitoring To Zero the Alarm CounterHhmmss Time Set MM flashing Hhmmss OFF Time MM flashing Link DIL Switch Pole Position Selected Function Configuring the Clock ModuleC1651 Clock Module DIL switch 1 and Link 1 Settings Link Position Selected FunctionWP DIL Switch Error Message 16.3 C1651 Clock Module PCB FeaturesClock Module Error Messages Eeprom Error MessageEeprom 0 Error Eeprom 1 Error ROM Checksum Error messageMechanical, Electrical & Environmental Specification Mechanical Mx-1000 Series Panel Repeater Specification ZoneBattery Mx-1000 Series Panel Repeater Specification Zone Powersonic

Mx-1000 specifications

The BRK electronic Mx-1000 is an innovative and versatile device designed for both home and industrial use, primarily focusing on smoke and carbon monoxide detection. Its advanced features enhance safety, ensuring peace of mind for users in various environments.

One of the standout features of the Mx-1000 is its dual-sensor technology. It combines both photoelectric and ionization sensors, maximizing its ability to detect different types of smoke. Photoelectric sensors are highly effective at identifying smoldering fires, which are often associated with slow-burning materials. On the other hand, ionization sensors excel at detecting fast-flaming fires. This dual capability ensures comprehensive fire detection, making the Mx-1000 one of the most reliable devices in its category.

Another notable characteristic is its built-in carbon monoxide detector. Carbon monoxide is a silent killer, and the Mx-1000 addresses this threat by providing early warning signals when harmful levels of this gas are detected. The integration of both smoke and carbon monoxide detection in a single unit simplifies safety measures and reduces the number of devices required for home and workplace safety.

The Mx-1000 is equipped with advanced digital technology that enhances its functionality. A state-of-the-art microprocessor evaluates alarm conditions more intelligently, which minimizes the chances of false alarms. This feature is particularly beneficial for households that might experience frequent smoke triggers from cooking or other benign sources.

User-friendliness is a key design aspect of the Mx-1000. It features a clear LED display that indicates the operational status, and a simple test button allows users to verify functionality with ease. The device also features a low-battery indicator, ensuring users are always informed about its operational state.

Installation is straightforward, with options for both wall and ceiling mounting to accommodate various room layouts. The Mx-1000 is designed to appeal to a wide range of customers, from DIY enthusiasts to professional installers.

In addition to its technological advancements, the BRK electronic Mx-1000 is built with reliability in mind. Its durable construction is meant to endure various conditions, ensuring longevity and consistent performance over time. This combination of top-tier technology, user-friendly features, and robust design makes the Mx-1000 a trusted choice for those seeking comprehensive safety solutions in smoke and carbon monoxide detection.