8 Gas Information

A. Fuel Conversions

C. Gas Connection

Before making gas connections ensure that appliance be- ing installed is compatible with the available gas type.

Any natural or propane gas conversions necessary to meet the appliance and locality needs must be made by a qualified technician using Hearth & Home Technologies specified and approved parts.

Note: Have the gas supply line installed in accordance with local building codes, if any. If not, follow ANSI

223.1.Installation should be done by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter).

B. Gas Pressures

Proper input pressures are required for optimum appli- ance performance. Gas line sizing requirements need to be made following NFPA54.

WARNING

Fire Risk. Explosion Hazard.

High pressure will damage valve.

• Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 1/2 psig.

Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1/2 psig.

WARNING

Verify inlet pressures.

• High pressure may cause overfire condition.

• Low pressure may cause explosion.

Verify minimum pressures when other household gas appliances are operating.

Install regulator upstream of valve if line pressure is greater than 1/2 psig.

Pressure requirements for appliance are shown in the table below. Minimum pressures must be met when other household gas appliances are operating.

Pressure

Natural Gas

Propane

Minimum inlet pressure

5.0 inches

11.0 inches

w.c.

w.c.

 

Maximum inlet gas pressure

14.0 inches

14.0 inches

w.c.

w.c.

 

Manifold pressure

3.5 inches

10.0 inches

w.c.

w.c.

 

NOTE: A listed (and Commonwealth of Massachusetts ap- proved) 1/2 inch (13 mm) T-handle manual shut-off valve and flexible gas connector are connected to the 1/2 inch (13 mm) control valve inlet.

If substituting for these components, please consult local codes for compliance.

Refer to Reference Section 15 for location of gas line access in appliance.

NOTE: Gas line may be run from either side of the appliance provided the hole in the outer wrap does NOT exceed 2-1/2 inches in diameter and does not penetrate the firebox.

WARNING

Gas Leak Risk

Support control when attaching pipe to prevent bending gas line.

NOTE: The gap between supply piping and gas access hole may be caulked with high temperature caulk or stuffed with non-combustible, unfaced insulation to prevent cold air infiltration.

Ensure that gas line does not come in contact with outer wrap of appliance. Follow local codes.

Incoming gas line should be piped into the valve compartment and connected to the 1/2 inch connection on the manual shutoff valve.

Check all fittings and connections of appliance which may have loosened during shipping.

Heat & Glo • FB-IN-S, FB-GRAND-S783-910 Rev. G • 11/08

15

Image 15
Contents FB-GRAND-S FB-IN-S ModelsHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Tools and Supplies Needed Design and Installation ConsiderationsGetting Started Inspect Appliance and ComponentsInspect Firebox Inches Millimeters Fireplace Size RequirementsMinimum Fireplace Opening LocationClearances to Mantels or other Combustibles above Appliance ClearancesFoot minimum in snow regions Termination LocationsVent Termination Minimum Clearances Fire Risk Asphyxiation RiskMeasuring Standards Vent Information and DiagramsVent Table Key Horizontal VentingInstallation Preparation Installing Vent Pipe and Appliance Connecting Vent PipeVenting Components Placing, Securing and Leveling the Appliance Damper Flashing Kit Optional Installing Adaptor and Termination CapMasonry Factory Built Wood BurningMinimum inlet pressure Gas InformationFuel Conversions Gas Connection Gas PressuresHigh Altitude Installations Appliance Requirements Wiring the ApplianceON/OFF Switch Electrical InformationShock hazard Junction Box InstallationInstallation for Fan Optional Optional AccessoriesFAN Junction BOX Installing Trim Surrounds FinishingMantel Projections Ember Placement Appliance SetupClean the Appliance AccessoriesLogs Locating Tabs Grate Assembly Heat & Glo FB-IN-S, FB-GRAND-S 783-910 Rev. G 11/08 Instructions Positioning the Logs Model FB-IN-SLOG PlacementFlat Spot for Log #4 Replacing Glass Assembly Glass AssemblyAir Shutter Setting Removing Glass AssemblyOperating Instructions Before Lighting ApplianceBefore operating this appliance have a qualified technician Standing Pilot Ignition Lighting ApplianceDo not operate appliance with glass door removed Initial Break-in ProcedureCheck Pilot Flame Appearance After Appliance is LitFrequently Asked Questions Troubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionMaximum flame impingement. Follow lighting instruc Maintenance Tasks Maintaining and Servicing ApplianceRisk of injury or property damage Inspect Maintenance Tasks Reference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits Vent Kits ComponentsLog Set Assembly Service PartsPart number list on following Be ordered from an authorized dealer At DepotFB-IN-S GLA-FBIN Stocked FB-GRAND-S, FB-IN-SCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Important operating Contact Information

FB-GRAND-S, FB-IN-S specifications

Hearth and Home Technologies has consistently been at the forefront of innovation in the fireplace industry, and their FB-IN-S and FB-GRAND-S models exemplify this commitment to quality, efficiency, and style. Designed for modern living spaces, these products bring both aesthetic appeal and practicality to homeowners looking to enhance their environment with a sleek, efficient heating solution.

The FB-IN-S model is a testament to contemporary design, featuring a minimalist facade that fits seamlessly into any decor. Its built-in installation ensures that homeowners can create a clean and unobtrusive look, making it a great choice for those who prefer a more integrated approach to their heating solutions. The FB-IN-S is equipped with an advanced combustion technology that maximizes heat output while minimizing emissions, leading to a cleaner and more efficient burn. This model also features an easy-to-use electronic ignition system, allowing for quick starts and easy operation.

In contrast, the FB-GRAND-S model offers a grander experience with its expansive viewing area and larger firebox. This fireplace is perfect for those who want to make a statement in their living space. The large glass panel showcases the flickering flames, providing a mesmerizing visual that serves as a focal point in any room. The FB-GRAND-S shares the advanced combustion system with its counterpart, ensuring optimal efficiency and reduced environmental impact.

Both models boast high energy efficiency ratings, meaning they can provide warmth without significantly increasing energy costs. Hearth and Home Technologies has incorporated Smart Technology into these fireplaces, allowing users to control their unit remotely via smartphone apps. This feature adds a layer of convenience, enabling adjustments from anywhere in the home.

Safety is paramount, and both the FB-IN-S and FB-GRAND-S come with built-in safety features, such as a sealed combustion chamber and a safety shut-off system, ensuring peace of mind for users.

In summary, Hearth and Home Technologies' FB-IN-S and FB-GRAND-S fireplaces blend beauty and functionality. With modern designs, advanced heating technologies, and smart features, these models are perfect for anyone looking to elevate their home while enjoying efficient and stylish heating solutions. Whether opting for the subtle elegance of the FB-IN-S or the striking presence of the FB-GRAND-S, homeowners can trust Hearth and Home Technologies to deliver quality and performance.