Hearth and Home Technologies FB-IN-S, FB-GRAND-S owner manual Inspect Maintenance Tasks

Page 34

Inspect

 

Maintenance Tasks

 

 

 

Doors, Surrounds

1.

Assess condition of screen and replace as necessary. Recommend addition of screen if one is not present.

and Fronts

 

 

2.

Inspect for scratches, dents or other damage and repair as necessary.

 

 

 

 

 

3.

Verify no obstructions to airflow through the louvers.

 

 

 

 

4.

Verify maintenance of proper clearance to combustible household objects.

 

 

 

Gasket Seal, Glass

1.

Inspect gasket seal and its condition.

Assembly and Glass

 

 

2.

Inspect glass panels for scratches and nicks that can lead to breakage when exposed to heat.

 

 

 

 

 

3.

Confirm there is no damage to glass or glass frame. Replace as necessary.

 

 

 

 

4.

Verify that latches engage properly, clip studs are not stripped, and glass attachment components are

 

 

intact and operating properly. Replace as necessary.

 

5.

Clean glass. Replace glass assembly if severely coated with silicate deposits that cannot be removed.

 

 

 

Valve Compartment

1.

Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these areas. Screw

and Firebox Top

 

tips that have penetrated the sheet metal are sharp and should be avoided.

 

 

 

 

2.

Remove any foreign objects.

 

 

 

 

3.

Verify unobstructed air circulation.

 

 

 

Logs

1.

Inspect for broken, damaged, or missing logs. Replace as necessary.

 

 

 

 

2.

Verify correct log placement and no flame impingement causing sooting. Correct as necessary.

 

 

 

Firebox

1.

Inspect for paint condition, warpage, corrosion or perforation. Contact Dealer for inspection.

 

 

 

 

2.

Replace appliance if firebox has been perforated.

 

 

 

Burner Ignition and

1.

Verify burner is properly secured and aligned with pilot or igniter.

Operation

 

 

2.

Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if necessary.

 

 

 

 

 

3.

Replace ember materials with new dime-size and shape pieces. Do not block ports or obstruct lighting paths.

 

 

 

 

4.

Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.

 

 

 

 

5.

Inspect for lifting or other flame problems.

 

 

 

 

6.

Verify air shutter is clear of dust and debris.

 

 

 

 

7.

Inspect orifice for soot, dirt or corrosion.

 

 

 

 

8.

Verify manifold and inlet pressures. Adjust regulator as required.

 

 

 

 

9.

Inspect pilot flame strength. Clean or replace orifice as necessary.

 

 

 

 

10.

Inspect thermocouple/thermopile or IPI sensor rod for soot, corrosion and deterioration. Clean with emery

 

 

cloth or replace as required.

 

 

 

11. Verify millivolt output. Replace as necessary.

 

 

 

Venting

1.

Inspect venting for blockage or obstruction such as bird nests, leaves, etc.

 

 

 

 

2.

Confirm that termination cap remains clear and unobstructed by plants, etc.

 

 

 

 

3.

Verify that termination cap clearance to subsequent construction (building additions, decks, fences or

 

 

sheds) has been maintained.

 

 

 

 

4.

Inspect for corrosion or separation.

 

 

 

 

5.

Verify weather stripping, sealing and flashing remains intact.

 

 

 

 

6.

Inspect draft shield to verify it is not bent, damaged or missing.

 

 

 

Remote controls

1.

Verify operation of remote.

 

 

 

 

2.

Replace batteries in remote transmitters and battery-powered receivers.

 

 

 

 

3.

Verify batteries have been removed from battery back-up IPI systems to prevent premature battery failure

 

 

or leaking.

34

Heat & Glo • FB-IN-S, FB-GRAND-S783-910 Rev. G • 11/08

Image 34
Contents Models FB-GRAND-S FB-IN-SCongratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Inspect Appliance and Components Design and Installation ConsiderationsGetting Started Tools and Supplies NeededInspect Firebox Location Fireplace Size RequirementsMinimum Fireplace Opening Inches MillimetersClearances Clearances to Mantels or other Combustibles above ApplianceFire Risk Asphyxiation Risk Termination LocationsVent Termination Minimum Clearances Foot minimum in snow regionsHorizontal Venting Vent Information and DiagramsVent Table Key Measuring StandardsInstallation Preparation Connecting Vent Pipe Installing Vent Pipe and ApplianceVenting Components Placing, Securing and Leveling the Appliance Factory Built Wood Burning Installing Adaptor and Termination CapMasonry Damper Flashing Kit OptionalGas Pressures Gas InformationFuel Conversions Gas Connection Minimum inlet pressureHigh Altitude Installations Electrical Information Wiring the ApplianceON/OFF Switch Appliance RequirementsOptional Accessories Junction Box InstallationInstallation for Fan Optional Shock hazardFAN Junction BOX Finishing Installing Trim SurroundsMantel Projections Accessories Appliance SetupClean the Appliance Ember PlacementLogs Locating Tabs Grate Assembly Heat & Glo FB-IN-S, FB-GRAND-S 783-910 Rev. G 11/08 Positioning the Logs Model FB-IN-SLOG Placement InstructionsFlat Spot for Log #4 Removing Glass Assembly Glass AssemblyAir Shutter Setting Replacing Glass AssemblyBefore Lighting Appliance Operating InstructionsBefore operating this appliance have a qualified technician Lighting Appliance Standing Pilot IgnitionAfter Appliance is Lit Initial Break-in ProcedureCheck Pilot Flame Appearance Do not operate appliance with glass door removedFrequently Asked Questions Symptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingMaximum flame impingement. Follow lighting instruc Maintaining and Servicing Appliance Maintenance TasksRisk of injury or property damage Inspect Maintenance Tasks Appliance Dimension Diagram Reference MaterialsVent Kits Components Direct Vent Flex Liner KitsService Parts Log Set AssemblyPart number list on following At Depot Be ordered from an authorized dealerFB-IN-S GLA-FBIN FB-GRAND-S, FB-IN-S StockedCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information Important operating

FB-GRAND-S, FB-IN-S specifications

Hearth and Home Technologies has consistently been at the forefront of innovation in the fireplace industry, and their FB-IN-S and FB-GRAND-S models exemplify this commitment to quality, efficiency, and style. Designed for modern living spaces, these products bring both aesthetic appeal and practicality to homeowners looking to enhance their environment with a sleek, efficient heating solution.

The FB-IN-S model is a testament to contemporary design, featuring a minimalist facade that fits seamlessly into any decor. Its built-in installation ensures that homeowners can create a clean and unobtrusive look, making it a great choice for those who prefer a more integrated approach to their heating solutions. The FB-IN-S is equipped with an advanced combustion technology that maximizes heat output while minimizing emissions, leading to a cleaner and more efficient burn. This model also features an easy-to-use electronic ignition system, allowing for quick starts and easy operation.

In contrast, the FB-GRAND-S model offers a grander experience with its expansive viewing area and larger firebox. This fireplace is perfect for those who want to make a statement in their living space. The large glass panel showcases the flickering flames, providing a mesmerizing visual that serves as a focal point in any room. The FB-GRAND-S shares the advanced combustion system with its counterpart, ensuring optimal efficiency and reduced environmental impact.

Both models boast high energy efficiency ratings, meaning they can provide warmth without significantly increasing energy costs. Hearth and Home Technologies has incorporated Smart Technology into these fireplaces, allowing users to control their unit remotely via smartphone apps. This feature adds a layer of convenience, enabling adjustments from anywhere in the home.

Safety is paramount, and both the FB-IN-S and FB-GRAND-S come with built-in safety features, such as a sealed combustion chamber and a safety shut-off system, ensuring peace of mind for users.

In summary, Hearth and Home Technologies' FB-IN-S and FB-GRAND-S fireplaces blend beauty and functionality. With modern designs, advanced heating technologies, and smart features, these models are perfect for anyone looking to elevate their home while enjoying efficient and stylish heating solutions. Whether opting for the subtle elegance of the FB-IN-S or the striking presence of the FB-GRAND-S, homeowners can trust Hearth and Home Technologies to deliver quality and performance.