Hearth and Home Technologies 3100-I, 830-0381 owner manual Air quality and your Quadra-Fire Insert

Page 17

3100-I ACT WOOD INSERT

R

air quality AND your Quadra-Fire Insert

In recent years there has been an increasing concern about the quality of our air. Much of the blame for poor air quality has been placed on the burning of wood for home heating. In order to improve this situation we at Quadra-Fire have developed cleaner burning inserts that surpass the stringent requirements for emissions established by our governing agencies. Your 3100-I ACT, like any other appliance, must be properly operated in order to insure that they perform the way they are designed to perform. Improper operation and maintenance may cause any wood burning unit to release more particulate, adversely affecting the environment.

The story of the Three Burning Stages . . .

It helps to know a little about the actual burn process, which entails three discernible burning stages. The first stage is called the kindling stage. During this stage the fuel reaches the boiling temperature of water, 212°F, evaporating the moisture found to some degree in all wood.

Because the process takes heat from the insert during this initial drying stage, each new load of wood reduces the chances for a good, clean burn. For this reason it is always best to burn dry, seasoned firewood, and operate the controls properly. The control on the right side of your insert is called the Start-Up Air Control and is used primarily during this first kindling stage of burning.

During the secondary stage, the wood gives off flammable gases which burn above the fuel with bright flames. These flames above the fuel must be maintained until the third stage to insure proper burning. During this stage you may adjust your insert for a low burn rate. To achieve a low burn rate it is necessary to close down the air while still maintaining some flames. If the flames tend to go out, the setting is too low. The Primary Control, located in the center of the insert beneath the ashcatcher, will assist you in adjusting the insert for a low burn rate.

The third stage of burning is the charcoal stage. This happens when the flammable gases have been burned and the charcoal remains. The coals burning with hot blue flames is a naturally clean portion of the burn. It is very important to reload your insert while enough lively hot coals remain in order to provide the amount of heat needed to dry and rekindle the next load of wood. Open up both controls for a short while before reloading to liven up the coal bed. You should also break up any large chunks and distribute the coals so the new wood is laid on hot coals. Leave both controls open until the new wood load is burning well enough to maintain the secondary stage of burning and then set controls to your desired heat output setting.

START-UP AIR SYSTEM

The combustion air enters at the rear of the firebox through the rear air tubes. This air supply is controlled by the Start-Up Air Control.

PRIMARY AIR SYSTEM

The primary air enters at the upper front of the firebox near the top of the glass door. This preheated air supplies the necessary fresh oxygen to mix with the unburned gases, helping to create secondary, tertiary and quaternary combustion. This air is regulated by the Primary Air Control. For more primary air (more heat), push rod in. For less primary air (less heat), pull rod out.

In other words . . .

Pulling either control towards you closes off the air available to the insert in that area. Pushing either control opens it, allow- ing air circulation to the area. A good analogy to remember for this procedure is the gas pedal on your car. Pushing in the gas pedal makes the engine run faster. Letting off (pulling the control back) makes the car run slower.

Figure 17A

Primary Air Control

Start-Up Air Control

 

OPEN - PUSH IN

CLOSE - PULL OUT

 

 

 

 

September 1, 2008

250-638D

Page 17

Image 17
Contents Hot glass will cause burns ACT Wood InsertACT Wood Insert Sample of Serial Number / Safety LabelTable of Contents Front View Insert Dimensions TOP ViewSide View ACT Wood Insert Clearances to Combustibles Installation Installation recommendationsListings Chimney HEIGHT/DRAFTAlternate Floor Protection Worksheet General Installation ProcedureOvalizing Round Stainless Steel Liners Chimney RequirementsChimney Height Chimney TOP ViewMasonry Fireplace Using DIRECT-CONNECT Method Installation OptionsFactory built zero clearance fireplace Usa installations onlyUse of Leveling Bolts Installation in CanadaSecuring Liner to Chimney Ring Masonry and HEAT-CIRCULATINGDoor Handle Assembly Installation of Panel SET and TrimView of L Bracket Installed Description SizeFAN Speed Control ADJUSTMENT, if Necessary FAN Blower Installation InstructionsSee B Zero Clearance Adjustable Trim SUPPORT, 2 toWood Selection and Storage OverfiringBuilding a Fire Fan operating instructions ACT Wood Insert Operating TipsASH Removal BTU / Hr Start-Up Air Control Primary ControlStory of the Three Burning Stages Air quality and your Quadra-Fire InsertMaintenance See C Brick replacement instructionsBrick Set Part Number Description Exploded ViewLVR-31-NL Service partsGlass Size 15-1/2 w x 11-3/8 h AccessoriesDate of Service Performed By Description of Service Service And Maintenance LogService And Maintenance Log Cont’d Homeowner’s Notes Hearth & Home Technologies Limited Warranty Warranty PolicyHearth & Home Technologies Limited Warranty Cont’d ACT Wood Insert