Hearth and Home Technologies 3100-I, 830-0381 owner manual Installation Options

Page 9

3100-I ACT WOOD INSERT

R

INSTALLATION OPTIONS

Refer to: Clearances to Combustibles on page 5, Canadian Installation requirements on page 11,

Hearth Requirements on page 5 and Zero Clearance Adjustable Support Kit on page 14.

MASONRY FIREPLACE

USING DIRECT-CONNECT METHOD

The Quadra-Fire 3100-I ACT Insert conforms with the UL Standard for Safety 1482 and ULC S628 (Canada) in all respects, and is approved to UL & ULC safety standards for installation and use within a fireplace with a masonry chimney in accordance with NFPA No. 211, with or without a direct flue collar connection. A starter pipe is required to reach to the bottom of the existing flue.

1.Secure the fireplace damper in the open position. If this cannot be accomplished, it will be necessary to remove the damper.

2.Seal the damper area around the chimney liner with a high temperature sealant.

3.The chimney should be examined for cracks, loose mortar, and other signs of deterioration and blockage. The insert should not be installed until it is determined that the chim- ney is safe for use. Since an oversized flue contributes to the accumulation of creosote, the size of the flue should be checked to determine that it is not too large for the insert. The chimney should also be checked to ensure it meets the minimum standard of the National Fire Protection Associa- tion (NFPA) Standard 211. The following bullets list the more critical requirements for a properly constructed chimney:

The masonry wall of the chimney, if brick or modular block, must be a minimum of 4 inches (102mm) nominal thickness. A chimney of rubble stone must be at least 12 inches (305mm) thick

The chimney must have a fire clay flue liner (or equiva- lent) with a minimum thickness of 5/8” (16mm) and must be installed with refractory mortar. An equivalent liner must be a listed chimney liner system or other approved material.

A chimney inside the house must have at least 2 inches

(51mm) of clearance to the combustible structure. A chim- ney outside the house must have at least 1 inch (25mm) clearance to the combustible structure. Non-combustible fire stops must be installed at the spaces where the chimney passes through floors and/or ceiling (See Figure 8A and 8B on page 8).

NOTE: In Canada, a full reline is required.

Masonry Chimney

Full Listed

 

Flue Tile

 

Mantel

Liner Option

 

Air-tight Face Seal

Direct Connect

 

Seal Option

Damper Area

Minimum Starter

 

 

Pipe Option

SEAL DAMPER AREA OR FACE SEAL

Figure 9A - Installation Into Masonry Fireplace

METAL HEAT CIRCULATING masonry

The Quadra-Fire 3100-I Insert conforms with the safety stan- dard UL-1482 and ULC S628 (Canada) in all respects and is approved to UL & ULC safety standards for installation and use within a fireplace with masonry chimney, in accordance with NFPA No. 211, with or without a direct flue collar con- nection. A starter pipe is required into existing chimney.

Mantel

Listed Liner

SEAL DAMPER AREA OR FACE SEAL

Figure 9B - Installation Into Metal Heat Circulating

Showing Use Of Starter Pipe

 

 

 

 

September 1, 2008

250-638D

Page

Image 9
Contents Hot glass will cause burns ACT Wood InsertACT Wood Insert Sample of Serial Number / Safety LabelTable of Contents Insert Dimensions TOP View Side ViewFront View ACT Wood Insert Clearances to Combustibles Installation Installation recommendationsListings Chimney HEIGHT/DRAFTAlternate Floor Protection Worksheet General Installation ProcedureOvalizing Round Stainless Steel Liners Chimney RequirementsChimney Height Chimney TOP ViewMasonry Fireplace Using DIRECT-CONNECT Method Installation OptionsFactory built zero clearance fireplace Usa installations onlyUse of Leveling Bolts Installation in CanadaSecuring Liner to Chimney Ring Masonry and HEAT-CIRCULATINGDoor Handle Assembly Installation of Panel SET and TrimView of L Bracket Installed Description SizeFAN Speed Control ADJUSTMENT, if Necessary FAN Blower Installation InstructionsSee B Zero Clearance Adjustable Trim SUPPORT, 2 toOverfiring Building a FireWood Selection and Storage Fan operating instructions ACT Wood Insert Operating TipsASH Removal BTU / Hr Start-Up Air Control Primary ControlStory of the Three Burning Stages Air quality and your Quadra-Fire InsertMaintenance Brick replacement instructions Brick Set Part NumberSee C Description Exploded ViewLVR-31-NL Service partsGlass Size 15-1/2 w x 11-3/8 h AccessoriesDate of Service Performed By Description of Service Service And Maintenance LogService And Maintenance Log Cont’d Homeowner’s Notes Hearth & Home Technologies Limited Warranty Warranty PolicyHearth & Home Technologies Limited Warranty Cont’d ACT Wood Insert