brick replacement instructions

The firebox of your Quadra-Fire 3100-I ACT Insert is lined with high quality firebrick which has exceptional insulating proper- ties. There is no need for a grate, simply build a fire on the firebox of your insert.

Figure 19A

3





 

3

4

 

5

 

4

1

3

 

3

1

 

 

 

1

1

1

 

1

1

1

1

 

1

 

1

1

 

 

Brick Set Part Number: 831-1830

1.Remove all old brick and ash from unit.

2.Remove new brick set from box and lay out to diagram as shown in Figure 19A.

3.Lay bottom bricks in unit.

4.Install rear bricks on the top of the bottom bricks. Slide top of bricks under clip on back of firebox wall and push bottom of brick back.

5.Install side bricks. Slide top of brick under clips on side of firebox and push the bottom of the brick until it is flush with the side of the unit.

Nbr

Brick Size

Qty in Set

1

9 x 4.5 x 1.25”

12

2

9 x 4.5 x 1.25”

2

3

9 x 3.25 x 1.25”

4

4

9 x 2.25 x 1.25”

2

5

3 x 2.25 x 1.25”

1

 

 

 

Use Part Number 832-0550 when ordering individual brick and provide the brick dimensions or copy this page and mark desired brick and take it your authorized dealer.

BAFFLE REMOVAL & INSTALLATION

NOTE: The baffle in the 3100-I ACT Insert is 2700° Fiber Board. Removing hardware exposed to combustion processes can be frustrating. If your reason for removing the baffle is simply to clean the chimney, you have alternatives which will save time and effort. Call a qualified chimney sweep or an authorized Quadra-Fire dealer for details.

1.Remove all ash from the firebox, and extinguish all hot embers before disposal into a metal container.

2.Remove the ceramic blanket from above the baffle.

3.With a 3/16” allen wrench, remove the 2 front manifold tube retainer bolts on the air channel under the end of the front tubes. NOTE: Soak the bolts with penetrating oil for at least 15 minutes before trying to remove them. See Figure 19B.

4.To remove the manifold tubes, slide the tube to one side until one end is out of its hole. Then, while lifting that end of the fiber board, pull the tube up over the air channel and out of the hole at the other end. NOTE: When replacing the manifold tubes, be sure the tube with the larger holes is placed in the front for your insert to operate properly.

5.Slide fiber board forward to front of stove, tilt down and slide to the door. Tilt to one side and slide through door.

See Figure 19C.

6.Keep the fiber board baffle tilted as you lift it out of the door.

7.To install the fiber board baffle, repeat steps 2 through 4 in reverse. Be sure that the fiber board and ceramic blanket are pushed back fully.

First tube has larger holes

Allen

 

Allen wrench

wrench on

on retainer bolt

retainer

 

bolt.

 

Figure 19B

Figure 19C

 

 

 

 

September 1, 2008

250-638D

Page 19

Image 19
Contents Hot glass will cause burns ACT Wood InsertACT Wood Insert Sample of Serial Number / Safety LabelTable of Contents Side View Insert Dimensions TOP ViewFront View ACT Wood Insert Clearances to Combustibles Chimney HEIGHT/DRAFT Installation recommendationsInstallation ListingsAlternate Floor Protection Worksheet General Installation ProcedureChimney TOP View Chimney RequirementsOvalizing Round Stainless Steel Liners Chimney HeightMasonry Fireplace Using DIRECT-CONNECT Method Installation OptionsFactory built zero clearance fireplace Usa installations onlyMasonry and HEAT-CIRCULATING Installation in CanadaUse of Leveling Bolts Securing Liner to Chimney RingDescription Size Installation of Panel SET and TrimDoor Handle Assembly View of L Bracket InstalledFAN Speed Control ADJUSTMENT, if Necessary FAN Blower Installation InstructionsSee B Zero Clearance Adjustable Trim SUPPORT, 2 toBuilding a Fire OverfiringWood Selection and Storage BTU / Hr Start-Up Air Control Primary Control ACT Wood Insert Operating TipsFan operating instructions ASH RemovalStory of the Three Burning Stages Air quality and your Quadra-Fire InsertMaintenance Brick Set Part Number Brick replacement instructionsSee C Description Exploded ViewLVR-31-NL Service partsGlass Size 15-1/2 w x 11-3/8 h AccessoriesDate of Service Performed By Description of Service Service And Maintenance LogService And Maintenance Log Cont’d Homeowner’s Notes Hearth & Home Technologies Limited Warranty Warranty PolicyHearth & Home Technologies Limited Warranty Cont’d ACT Wood Insert