11 Finishing

A. Non-Combustible Materials

Materials which will not ignite and burn, composed of any combination of the following:

-

Steel

-

Iron

-

Brick

-

Tile

-

Concrete

-

Slate

-

Glass

-

Plasters

Materials reported as passing ASTM E 136, Standard

Test Method for Behavior of Metals, in a Vertical Tube Furnace at 750° C

B. Combustible Materials

Materials made of or surfaced with any of the following materials:

-

Wood

-

Compressed paper

-

Plant fibers

-

Plastic

Any material that can ignite and burn; flame proofed or not, plastered or un-plastered

C. Hearth Extension

WARNING! Risk of fire! High temperatures, sparks, embers or other burning material falling from the fireplace may ignite flooring or concealed combustible surfaces.

Protective metal hearth strips MUST be installed.

Hearth extensions MUST be installed exactly as specified.

Table 11.1

R = 1/k x inches of thickness

Table 11.2

You MUST use a hearth extension with this fireplace.

This fireplace has been tested and approved for use with a hearth extension insulated to a minimum R value of 1.03.

The hearth extension material MUST be covered with tile, stone or other non-combustible material.

Manufactured hearth materials will usually have a published R value (resistance to heat) or k value (conductivity of heat). Refer to the formula in Table 11.1 to convert a k value to an R value,

Refer to Table 11.2 for hearth extension insulation alternatives.

C

AB

CAT. #

 

A

B

C

HX4

in

66

20

12

 

mm

1676

508

305

Figure 11.1 Hearth Extension Dimensions

Hearth Extension Insulation Alternatives-Total minimum R Value must equal 1.03

 

 

 

Minimum

 

k per inch

r per inch

thickness

Material

thick

thick

required

Hearth & Home HX3, HX4 (Micore 300™)

0.49

2.06

1/2 in.

 

 

 

 

USG Micore 160™

0.39

2.54

1/2 in.

USG Durock™ Cement Board

1.92

0.52

2 in.

Cement Mortor

5.0

0.20

5-1/8 in.

 

 

 

 

Common Brick

5.0

0.20

5-1/8 in.

Ceramic Tile

12.50

0.08

12-1/4 in.

 

 

 

 

Armstrong™ Privacy Guard Plus

0.46

2.18

1/2 in.

Marble

14.3-20.0

0.07-0.05

14-5/8 in. - 20-3/8 in.

38

Heat & Glo • HST-48D US-CAN4012-040 • Rev F • 11/08

Image 38
Contents Hot screen/mesh and glass doors will cause burns Wood Burning FireplaceOperation Fire RiskNumber Listing Label Information/LocationGrate User Guide Table of ContentsInstaller Guide Warranty Hearth & Home Technologies Limited Warranty CONDITIONS, Exclusions & Limitation of LiabilityHeat & Glo HST-48D US-CAN 4012-040 Rev F 11/08 Non-Combustible Materials Listing and Code ApprovalsAppliance Certification Combustible MaterialsHot glass will cause burns Operating InstructionsYour Fireplace Grate Seasoned WoodStarting a Fire FirescreenOptional Components Glass DoorsVented Gas Log Sets & Gas Log Lighters Clear SpaceWood Fuel Hardwood vs SoftwoodDisposal of Ashes Maintainance and ServiceChimney Inspection/Cleaning Inspect Grate Glass CleaningCheck Firebox Refractory Frequency As desiredTroubleshooting Guide Start Fire Problems Possible Cause SolutionGetting Started Typical Fireplace SystemNegative Pressure Design and Installation ConsiderationsDraft Locating Fireplace & Chimney Frequently open doors Central heat outlets or returnsInspect Fireplace and Components Tools and Supplies NeededFireplace System Requirements 1676 mm Hearth Framing & ClearancesSelect Fireplace Location Clearances Clearances to Combustible MaterialsSidewalls/Surrounds Frame the FireplacePosition the Fireplace Installation of FireplaceThings to Consider Place Protective Metal Hearth StripsFt min. from top of uppermost chimney section to air inlet YESOutside Air Install Outside Air KitHood Wire Ties Chimney Assembly Maintain minimum height of chimney above roofChimney Requirements C,fUsing Offsets/Returns ExampleInstall Chimney Air Kit Assemble Chimney SectionsInstall Ceiling Firestops Installing the Ceiling FirestopInstall Attic Insulation Shield 330 mmCut out Hole in Roof Complete InstallationInstall Flashing Chimney Termination Requirements Flat RoofsChase Installations Construct the ChaseInstall as per Sections 7 Install Fireplace & ChimneyInstall Chase Top Caulk all seams to prevent leaks Refer to FigureInstall Termination Cap ST1175/ST475 Square Termination Cap Installing a TCT1175 Terra Cotta Cap TCT1175 Terra Cotta CapField Constructed Shrouds ShroudsRadiation Shield Mailbox Style Shroud radiation shield required = 1/k x inches of thickness FinishingHearth Extension High temperature sealant Finishing MaterialFireplace opening 1194 mm Width of fireplace 305 mm Combustible MantelWood Burning Inserts AccessoriesGas Log/Lighter Provision Gas Code, Ansi Z223.1Heat & Glo HST-48D US-CAN Fireplace DimensionsReference Materials Rev F 11/081676 mm 508 mm 13 mm 457 mm Chimney ComponentsCatalog # Inside Diameter39-7/8 711 mm 51 mm25-1/4 14-3/4 375 mm 584 mm Service Parts HST-48DDo not Discard this Manual