7 Installing Vent Pipe and Appliance

A. Venting Components

CAUTION

Sharp Edges

Wear protective gloves and safety glasses during installation.

The vertical vent termination system installed on this model includes:

One 3-foot section stainless steel flexible pipe (included with insert).

One length of 3-inch flexible vent pipe for combustion air (included with vent kit).

Flexible vent pipe for exhaust air (included with vent kit).

One pipe-to-cap adaptor (included with vent kit).

One vertical termination cap (included with vent kit).

B. Connecting Vent Pipe

Reference instructions in the termination kit.

Install the 3-inch flexible vent pipe(s) down through the chimney.

Secure the exhaust flexible vent pipe to the 3 foot section stainless steel flexible vent pipe using the factory- installed 3-inch collar in the stainless steel section of pipe (see Figure 7.1).

Use 3 screws to attach either a 4 foot or 30 foot section of inlet air vent to the inlet collar on the collar slide plate (see Figure 7.1). NOTE: The collar slide plate may be removed from appliance to aid installation.

Seal opening between flex vent and chimney just above insert. Unfaced fiberglass insulation may be used for this purpose.

Note: To achieve optimum performance of insert, minimize or avoid bends in exhaust vent pipe.

TERMINATION

CAP

ADAPTOR

EXHAUST COLLAR

INLET AIR COLLAR

EXHAUST

VENT PIPE

V= 14 FT. MINIMUM 50 FT. MAXIMUM

3 INCH COLLAR

(Factory installed to

stainless steel section)

WARNING: DO NOT

BLOCK PIPE END WITH

INSULATION OR ANY OTHER

SEALING MATERIAL

STAINLESS STEEL

PIPE - 3 FT. MIN.

REQUIRED (INCLUDED)

INLET AIR

VENT PIPE

COLLAR ATTACHMENT

BRACKET

Figure 7.1

Quadra-FireQVI-30FB-S2020-910 Rev. F • 9/08

11

Image 11
Contents Commonwealth of Massachusetts ModelsModel Number Serial Number Homeowner Reference InformationTable of Contents Listing and Code Approvals Tools and Supplies Needed Design and Installation ConsiderationsGetting Started Inspect Appliance and ComponentsLocation Fireplace Size RequirementsMinimum Fireplace Opening Minimum fireplace opening requirements are shown in FigureClearances to Mantels or other Combustibles above Appliance Clearances Foot minimum in snow regions Termination Locations Vent Termination Minimum Clearances Fire Risk Asphyxiation RiskMeasuring Standards Vent Information and DiagramsVent Table Key Horizontal VentingInstallation Preparation Reference instructions in the termination kit Installing Vent Pipe and ApplianceConnecting Vent Pipe Venting ComponentsPlacing, Securing and Leveling the Appliance Damper Flashing Kit Optional Installing Adaptor and Termination CapMasonry Factory Built Wood BurningGas Pressures Refer to for location of gas line access in ap- plianceGas Information Fuel Conversions Gas ConnectionHigh Altitude Installations Appliance Requirements Wiring the ApplianceON/OFF Switch Electrical InformationShock hazard Junction Box InstallationInstallation for Fan Optional Optional AccessoriesFAN Junction BOX Mantel Projections Installing Trim SurroundsFinishing Ember Placement Appliance SetupClean the Appliance AccessoriesPositioning the Logs Log Assembly LOGS-QVI30FBLog Placement Quadra-Fire QVI-30FB-S 2020-910 Rev. F 9/08 Quadra-Fire QVI-30FB-S 2020-910 Rev. F 9/08 Replacing Glass Assembly Glass AssemblyAir Shutter Setting Removing Glass AssemblyBefore operating this appliance have a qualified technician Operating InstructionsBefore Lighting Appliance This appliance has a Standing Pilot IgnitionStanding Pilot Ignition Lighting ApplianceDo not operate appliance with glass door removed Initial Break-in ProcedureCheck Pilot Flame Appearance After Appliance is LitFrequently Asked Questions Standing Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Maximum flame impingement. Follow lighting instruc TroubleshootingSymptom Possible Cause Corrective Action Risk of injury or property damage Maintenance TasksMaintaining and Servicing Appliance Inspect Maintenance Tasks Reference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits Vent Kits ComponentsEnding Manufacturing Date Log Set AssemblyService Parts Beginning Manufacturing Date OctAt Depot Service Parts ListStocked Be ordered from an authorized dealer Valve AssemblyCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Important operating Contact Information