Hearth and Home Technologies QVI-30FB-S owner manual Electrical Information, Wiring the Appliance

Page 16

9 Electrical Information

A. Wiring the Appliance

Appliance Requirements

Note: Electrical wiring must be installed by a licensed electrician.

Note: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code, CSA C221.1.

A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.

This appliance DOES NOT require 110-120 VAC to operate.

It is recommended that a 110 VAC junction box be connected for use with fan or remote control. (See Figure 9.2 for junction box wiring).

WARNING

Wire 110V to electrical junction box.

Do NOT wire 110V to valve.

Do NOT wire 110V to wall switch.

Incorrect wiring will damage millivolt valves.

Incorrect wiring will override IPI safety lockout and may cause explosion.

CAUTION

Prevent accidental appliance operation when not attended.

Unplug or remove batteries from remote control if absent or if appliance will not be used for an extended period of time.

Property damage possible from elevated temperatures.

ON/OFF Switch

An ON/OFF switch is included with the decorative surround/decorative front and should attached to surround/facing. (See Installation instructions for remote control).

• If desired an additional wall switch or thermostat may be added to system as shown in Figure 9.1.

STANDING

 

PILOT

 

 

 

REMOTE SWITCH

 

 

PIGTAIL

 

 

ON

 

 

OFF

 

VALVE

ON/OFF

 

SWITCH

 

 

 

WHT

 

 

RED

OPTIONAL WALL SWITCH,

 

 

THERMOSTAT OR REMOTE

Figure 9.1

Standing Pilot Ignition Wiring Diagram

 

16

Quadra-FireQVI-30FB-S2020-910 Rev. F • 9/08

Image 16
Contents Models Commonwealth of MassachusettsHomeowner Reference Information Model Number Serial NumberTable of Contents Listing and Code Approvals Design and Installation Considerations Getting StartedInspect Appliance and Components Tools and Supplies NeededFireplace Size Requirements Minimum Fireplace OpeningMinimum fireplace opening requirements are shown in Figure LocationClearances Clearances to Mantels or other Combustibles above ApplianceTermination Locations Vent Termination Minimum ClearancesFire Risk Asphyxiation Risk Foot minimum in snow regionsVent Information and Diagrams Vent Table KeyHorizontal Venting Measuring StandardsInstallation Preparation Installing Vent Pipe and Appliance Connecting Vent PipeVenting Components Reference instructions in the termination kitPlacing, Securing and Leveling the Appliance Installing Adaptor and Termination Cap Masonry Factory Built Wood Burning Damper Flashing Kit OptionalRefer to for location of gas line access in ap- pliance Gas InformationFuel Conversions Gas Connection Gas PressuresHigh Altitude Installations Wiring the Appliance ON/OFF SwitchElectrical Information Appliance RequirementsJunction Box Installation Installation for Fan OptionalOptional Accessories Shock hazardFAN Junction BOX Finishing Installing Trim SurroundsMantel Projections Appliance Setup Clean the ApplianceAccessories Ember PlacementLog Placement Log Assembly LOGS-QVI30FBPositioning the Logs Quadra-Fire QVI-30FB-S 2020-910 Rev. F 9/08 Quadra-Fire QVI-30FB-S 2020-910 Rev. F 9/08 Glass Assembly Air Shutter SettingRemoving Glass Assembly Replacing Glass AssemblyOperating Instructions Before Lighting ApplianceThis appliance has a Standing Pilot Ignition Before operating this appliance have a qualified technicianLighting Appliance Standing Pilot IgnitionInitial Break-in Procedure Check Pilot Flame AppearanceAfter Appliance is Lit Do not operate appliance with glass door removedFrequently Asked Questions Symptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingMaximum flame impingement. Follow lighting instruc Maintaining and Servicing Appliance Maintenance TasksRisk of injury or property damage Inspect Maintenance Tasks Appliance Dimension Diagram Reference MaterialsVent Kits Components Direct Vent Flex Liner KitsLog Set Assembly Service PartsBeginning Manufacturing Date Oct Ending Manufacturing DateStocked Service Parts ListAt Depot Valve Assembly Be ordered from an authorized dealerCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information Important operating